Cervical pedicle screw fixation at C6 and C7 A cadaveric study

被引:8
|
作者
Li, Ye [1 ]
Liu, Jingchen [1 ]
Liu, Yulong [1 ]
Wu, Yuntao [1 ]
Zhu, Qingsan [1 ]
机构
[1] Jilin Univ, China Japan Union Hosp, Dept Orthopaed Surg, Changchun 130031, Peoples R China
关键词
C6; C7; cervical vertebra; pedicle screw; cadaver; MORPHOMETRIC EVALUATION; PLACEMENT; ACCURACY; MIDDLE; SPINE; VERTEBRAE;
D O I
10.4103/0019-5413.159678
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
Background: Cervical pedicle screw fixation is an effective method for treating traumatic and non traumatic injuries. But many studies have reported higher incidence of cervical pedicle penetration, so many research efforts have aimed at improving the accuracy of cervical screw fixation. Most of the anatomical studies on cervical pedicle screw placement previously published focused on the measurements of anatomical parameters, the entry point of pedicle screw is vague. We preliminarily designed a C3, C4 and C5 pedicle screw fixation method that had clear entry point and clinical cases confirmed that this method is feasible and safe. So we did this study of cervical pedicle screw fixation for C6 and C7 vertebrae. Materials and Methods: Fifteen cervical vertebrae specimens were prepared and bilateral pedicle screws were manually inserted into C6 and C7. The intersection of the horizontal line through the midpoint of the transverse process root and the vertical line through the intersection of the posterolateral and posterior planes of the isthmus was the entry point. The screws were inserted along the axis of the pedicle, with the screw axis coinciding with the pedicle. The pedicle was truncated axially and sagittally along the trajectory and the narrowest pedicular height (PH), pedicular width (PW), overall length of the screw channel (LSC), transverse angle (E) and vertical angle (F) were measured. Results: In C6, the PW and PH were 6.12+/-0.78 and 7.48+/-0.81 mm, respectively. In C7, the PW and PH were 6.85+/-0.73 and 8.03+/-0.38 mm, respectively. The LSC was 30.83+/-0.91 mm. Two E angles were identified, namely E1 and E2 and their values were 89.61+/-1.24 and 59.71+/-1.10 degrees, respectively. Meanwhile, F averaged 75.86+/-1.12 degrees. Conclusion: The intersection of the horizontal line through the midpoint of the transverse process root and vertical line through the intersection of the posterolateral and posterior planes of the isthmus can be used as an entry point for C6 and C7 pedicle screw fixation. The screws should be inserted at 60 or 90 degrees with the posterolateral isthmus in the horizontal plane and at 75 degrees with the posterior isthmus in the sagittal plane. The LSC should not exceed 30 mm.
引用
收藏
页码:465 / 470
页数:6
相关论文
共 50 条
  • [1] Cervical pedicle screw fixation at C6 and C7A cadaveric study
    Ye Li
    Jingchen Liu
    Yulong Liu
    Yuntao Wu
    Qingsan Zhu
    Indian Journal of Orthopaedics, 2015, 49 : 465 - 470
  • [2] Anterior cervical decompression and 360° fusion with posterior pedicle screws C6–C7
    R. Bassani
    R. Cecchinato
    C. Lamartina
    European Spine Journal, 2015, 24 : 652 - 653
  • [3] C6–C7 cervical disc arthroplasty in cervical disc herniation
    Jean-Marc Vital
    Louis Boissière
    Ibrahim Obeid
    European Spine Journal, 2013, 22 : 2136 - 2138
  • [4] Cervical kyphosis with myelopathy and anomalous vertebral artery entry at C7 treated with pedicle screw and rod fixation
    Yamazaki, Masashi
    Okawa, Akihiko
    Furuya, Takeo
    Koda, Masao
    ACTA NEUROCHIRURGICA, 2010, 152 (07) : 1263 - 1264
  • [5] Cervical kyphosis with myelopathy and anomalous vertebral artery entry at C7 treated with pedicle screw and rod fixation
    Masashi Yamazaki
    Akihiko Okawa
    Takeo Furuya
    Masao Koda
    Acta Neurochirurgica, 2010, 152 : 1263 - 1264
  • [6] Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique
    Desai, Shaunak
    Sethi, Anil
    Ninh, Christopher C.
    Bartol, Stephen
    Vaidya, Rahul
    EUROPEAN SPINE JOURNAL, 2010, 19 (11) : 1953 - 1959
  • [7] Pedicle screw fixation of the C7 vertebra using an anteroposterior fluoroscopic imaging technique
    Shaunak Desai
    Anil Sethi
    Christopher C. Ninh
    Stephen Bartol
    Rahul Vaidya
    European Spine Journal, 2010, 19 : 1953 - 1959
  • [8] ASYMPTOMATIC PERFORATION INTO THE ESOPHAGUS FOLLOWING A PLATE FIXATION OF THE VERTEBRAE C6/C7
    BAVASTRO, P
    SCHWEIGERT, R
    MEDIZINISCHE KLINIK, 1993, 88 (11) : 670 - 671
  • [9] Molecular bases of combined subtotal deficiencies of C6 and C7 - Their effects in combination with other C6 and C7 deficiencies
    Fernie, BA
    Wurzner, R
    Orren, A
    Morgan, BP
    Potter, PC
    Platonov, AE
    Vershinina, IV
    Shipulin, GA
    Lachmann, PJ
    Hobart, MJ
    JOURNAL OF IMMUNOLOGY, 1996, 157 (08): : 3648 - 3657
  • [10] Quantitative Gross and CT measurements of Cadaveric Cervical Vertebrae (C3 - C6) as Guidelines for the Lateral mass screw fixation
    Sangari, Santosh K.
    Heinneman, Thomas E.
    Conti, Mathew S.
    Dossous, Paul-Michel F.
    Dillon, David J.
    Tsiouris, Apostolos J.
    Pyo, Se Young
    Mtui, Estomih P.
    Hartl, Roger
    INTERNATIONAL JOURNAL OF SPINE SURGERY, 2016, 10