Integrated automated particle tracking microfluidic enables high-throughput cell deformability cytometry for red cell disorders

被引:24
|
作者
Guruprasad, Puneeth [1 ,2 ]
Mannino, Robert G. [1 ,2 ,3 ]
Caruso, Christina [3 ]
Zhang, Hanqing [4 ]
Josephson, Cassandra D. [5 ]
Roback, John D. [5 ]
Lam, Wilbur A. [1 ,2 ,3 ]
机构
[1] Georgia Inst Technol, Wallace H Coulter Dept Biomed Engn, Atlanta, GA 30332 USA
[2] Emory Univ, Atlanta, GA 30322 USA
[3] Emory Univ, Aflac Canc & Blood Disorder Ctr, Childrens Healthcare Atlanta, Dept Pediat,Sch Med, 412 Emory Childrens Ctr,2015 Uppergate Dr, Atlanta, GA 30322 USA
[4] Umea Univ, Dept Phys, Umea, Sweden
[5] Emory Univ, Sch Med, Dept Pathol & Lab Med, Ctr Transfus & Cellular Therapies, Atlanta, GA 30322 USA
基金
美国国家卫生研究院;
关键词
BLOOD-CELLS; ERYTHROCYTE DEFORMABILITY; FLOW-CYTOMETRY; STORAGE; TIME; MICROPARTICLES; HYDROXYUREA; DIAGNOSIS; VELOCITY; ANEMIA;
D O I
10.1002/ajh.25345
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Investigating individual red blood cells (RBCs) is critical to understanding hematologic diseases, as pathology often originates at the single-cell level. Many RBC disorders manifest in altered biophysical properties, such as deformability of RBCs. Due to limitations in current biophysical assays, there exists a need for high-throughput analysis of RBC deformability with single-cell resolution. To that end, we present a method that pairs a simple in vitro artificial microvasculature network system with an innovative MATLAB-based automated particle tracking program, allowing for high-throughput, single-cell deformability index (sDI) measurements of entire RBC populations. We apply our technology to quantify the sDI of RBCs from healthy volunteers, Sickle cell disease (SCD) patients, a transfusion-dependent beta thalassemia major patient, and in stored packed RBCs (pRBCs) that undergo storage lesion over 4 weeks. Moreover, our system can also measure cell size for each RBC, thereby enabling 2D analysis of cell deformability vs cell size with single cell resolution akin to flow cytometry. Our results demonstrate the clear existence of distinct biophysical RBC subpopulations with high interpatient variability in SCD as indicated by large magnitude skewness and kurtosis values of distribution, the "shifting" of sDI vs RBC size curves over transfusion cycles in beta thalassemia, and the appearance of low sDI RBC subpopulations within 4 days of pRBC storage. Overall, our system offers an inexpensive, convenient, and high-throughput method to gauge single RBC deformability and size for any RBC population and has the potential to aid in disease monitoring and transfusion guidelines for various RBC disorders.
引用
收藏
页码:189 / 199
页数:11
相关论文
共 50 条
  • [21] Microfluidic cell chips for high-throughput drug screening
    Chi, Chun-Wei
    Ahmed, A. H. Rezwanuddin
    Dereli-Korkut, Zeynep
    Wang, Sihong
    BIOANALYSIS, 2016, 8 (09) : 921 - 937
  • [22] High-throughput single-cell rheology in complex samples by dynamic real-time deformability cytometry
    Bob Fregin
    Fabian Czerwinski
    Doreen Biedenweg
    Salvatore Girardo
    Stefan Gross
    Konstanze Aurich
    Oliver Otto
    Nature Communications, 10
  • [23] High-throughput single-cell rheology in complex samples by dynamic real-time deformability cytometry
    Fregin, Bob
    Czerwinski, Fabian
    Biedenweg, Doreen
    Girardo, Salvatore
    Gross, Stefan
    Aurich, Konstanze
    Otto, Oliver
    NATURE COMMUNICATIONS, 2019, 10 (1)
  • [24] High-throughput microsphiltration to assess red blood cell deformability and screen for malaria transmission–blocking drugs
    Julien Duez
    Mario Carucci
    Irene Garcia-Barbazan
    Matias Corral
    Oscar Perez
    Jesus Luis Presa
    Benoit Henry
    Camille Roussel
    Papa Alioune Ndour
    Noemi Bahamontes Rosa
    Laura Sanz
    Francisco-Javier Gamo
    Pierre Buffet
    Nature Protocols, 2018, 13 : 1362 - 1376
  • [25] Microfluidic Cytometry for High-Throughput Characterization of Single Cell Cytoplasmic Viscosity Using Crossing Constriction Channels
    Wang, Ke
    Sun, Xiaohao
    Zhang, Yi
    Wei, Yuanchen
    Chen, Deyong
    Wu, Hengan
    Song, Zijian
    Long, Rong
    Wang, Junbo
    Chen, Jian
    CYTOMETRY PART A, 2020, 97 (06) : 630 - 637
  • [26] A Cascaded Droplet Microfluidic Platform Enables High-Throughput Single Cell Antibiotic Susceptibility Testing at Scale
    Zhang, Pengfei
    Kaushik, Aniruddha M.
    Hsieh, Kuangwen
    Li, Sixuan
    Lewis, Shawna
    Mach, Kathleen E.
    Liao, Joseph C.
    Carroll, Karen C.
    Wang, Tza-Huei
    SMALL METHODS, 2022, 6 (01):
  • [27] Microfluidic Impedance Flow Cytometry Enabling High-Throughput Single-Cell Electrical Property Characterization
    Chen, Jian
    Xue, Chengcheng
    Zhao, Yang
    Chen, Deyong
    Wu, Min-Hsien
    Wang, Junbo
    INTERNATIONAL JOURNAL OF MOLECULAR SCIENCES, 2015, 16 (05): : 9804 - 9830
  • [28] AUTOMATED DROPLET-BASED MICROFLUIDIC SYSTEMS FOR HIGH-THROUGHPUT SCREENING AND SINGLE CELL ANALYSIS
    Fang Qun
    Du Wenbin
    Gu Shuqing
    Zhu Ying
    Zhang Yunxia
    Sun Meng
    Yao Bo
    PROGRESS ON POST-GENOME TECHNOLOGIES AND MODERN NATURAL PRODUCTS, 2011, 2011, : 10 - 11
  • [29] Integrated Microfluidic Handheld Cell Sorter for High-Throughput Label-Free Malignant Tumor Cell Sorting
    Jiang, Fengtao
    Xiang, Nan
    ANALYTICAL CHEMISTRY, 2022, 94 (03) : 1859 - 1866
  • [30] High-throughput size and deformability-based cancer cell separation
    Yip, Gordon
    Ionescu, Daniel
    Johnson, Edwin
    Dick, Mikael
    Fang, Zecong
    Harb, Wael A.
    Hong, Bin
    Xu, Jie
    CANCER RESEARCH, 2014, 74 (19)