Monitoring of activated coagulation time in carotid endarterectomy

被引:15
|
作者
de Sousa, AA [1 ]
Dellaretti, MA
Faglioni, W
Carvalho, GTC
机构
[1] Fac Med Sci, Dept Neurosurg, BR-30150310 Belo Horizonte, MG, Brazil
[2] Santa Casa Hosp, BR-30150310 Belo Horizonte, MG, Brazil
来源
SURGICAL NEUROLOGY | 2005年 / 64卷
关键词
carotid endarterectomy; cervical carotid artery;
D O I
10.1016/j.surneu.2005.04.016
中图分类号
R74 [神经病学与精神病学];
学科分类号
摘要
Background: The objective of the present study was to evaluate the efficacy of monitoring activated coagulation time (ACT) during carotid endarterectomy (CEA) in reducing surgical risks and complications. Methods: A total of 175 consecutive patients who had CEA between July 2002 and January 2004 were studied. Activated coagulation time was monitored during the procedure in all patients. The results were compared with the data reported in the literature, and with those obtained in 2 previous series, totaling 1924 patients treated at the same service before the use of ACT. Results: Only 4 of the 175 patients had cerebral ischemia, with 3 of them almost completely recovering during hospitalization. Significant morbidity was 0.6% and mortality was 0.6%. No statistically significant difference in the incidence of cerebral ischemia or death was observed between symptomatic and asymptomatic patients. In the 2 previous series used for comparison, operated by the same author, we found 0.7% and 0.8% of significant morbidity and 1.4% and 2.6% of mortality, respectively. Most series in the literature have shown a higher significant morbidity than the present one, mainly in symptomatic patients. The incidence of hematoma in the present series was 5.7%, only 3 (1.7%) of them being significant. No increase in the frequency of hematomas was observed in cases where heparin was not reversed or in those using a shunt. In the 2 other previous series, the incidence of hematomas was 1.5% and 3.6%. Conclusions: Activated coagulation time monitoring during CEA was effective in evaluating the level of heparinization of patients during surgery and the immediate postoperative period. The comparison of the present series with the literature and with the previous series of the same service, before the use of ACT, permits also to conclude that the control of the level of heparinization seems to reduce the risk of perioperative and immediate postoperative ischemia. In addition, ACT monitoring also seems to be effective in diminishing the risk of postoperative cervical hematoma. (c) 2005 Elsevier Inc. All rights reserved.
引用
收藏
页码:S6 / S9
页数:4
相关论文
共 50 条
  • [21] Role of electroencephalographic monitoring in carotid endarterectomy
    Plestis, K
    Mizrahi, E
    Loubser, P
    Kantis, G
    Howell, J
    STROKE, 1996, 27 (01) : 18 - 18
  • [22] COMPUTERIZED EEG MONITORING FOR CAROTID ENDARTERECTOMY
    BAKER, AB
    ROXBURGH, AJ
    ANAESTHESIA AND INTENSIVE CARE, 1986, 14 (01) : 32 - 36
  • [23] Cerebrovascular monitoring during carotid endarterectomy
    Babikian, VL
    Cantelmo, NL
    STROKE, 2000, 31 (08) : 1799 - 1801
  • [24] Transcranial Doppler Monitoring in Carotid Endarterectomy
    Udesh, Reshmi
    Natarajan, Piruthiviraj
    Thiagarajan, Karthy
    Wechsler, Lawrence R.
    Crammond, Donald J.
    Balzer, Jeffrey R.
    Thirumala, Parthasarathy D.
    JOURNAL OF ULTRASOUND IN MEDICINE, 2017, 36 (03) : 621 - 630
  • [25] ELECTROENCEPHALOGRAM MONITORING DURING CAROTID ENDARTERECTOMY
    WARD, R
    FLYNN, T
    KELLEY, JT
    REILLY, E
    HANDEL, S
    JOURNAL OF CARDIOVASCULAR SURGERY, 1981, 22 (02): : 127 - 134
  • [26] EVALUATION OF ACTIVATED COAGULATION TIME AS A MONITORING PARAMETER OF POSTTHROMBOLYTIC HEPARINIZATION
    CETNAROWSKI, AB
    THOMAS, RW
    GOLDFARB, A
    DRUG INTELLIGENCE & CLINICAL PHARMACY, 1986, 20 (06): : 453 - 453
  • [27] The carotid endarterectomy: is it time to change approach?
    Bailey, M. A.
    Tunstall, R. G.
    Gough, M. J.
    Scott, D. J. A.
    ANNALS OF THE ROYAL COLLEGE OF SURGEONS OF ENGLAND, 2007, 89 (06) : 646 - 646
  • [28] INTRAOPERATIVE MONITORING DURING CAROTID ENDARTERECTOMY - REPLY
    CHO, I
    SMULLENS, SA
    STRELETZ, LJ
    FARIELLO, RG
    ANNALS OF NEUROLOGY, 1987, 22 (02) : 284 - 284
  • [29] APERIODIC ANALYSIS MONITORING DURING CAROTID ENDARTERECTOMY
    SILBERT, BS
    KOUMOUNDOUROS, E
    SCOTT, D
    CRONIN, K
    ANAESTHESIA AND INTENSIVE CARE, 1987, 15 (01) : 116 - 116
  • [30] Transcranial Doppler monitoring after carotid endarterectomy
    van der Schaaf, IC
    Horn, J
    Moll, FL
    Ackerstaff, RGA
    ANNALS OF VASCULAR SURGERY, 2005, 19 (01) : 19 - 24