Multi-element isotope dilution sector field ICP-MS: A precise technique for the analysis of geological materials and its application to geological reference materials

被引:518
|
作者
Willbold, M [1 ]
Jochum, KP [1 ]
机构
[1] Max Planck Inst Chem, D-55020 Mainz, Germany
关键词
isotope dilution; multi-element; ICP-MS; trace elements; geological reference materials; combined standard uncertainty;
D O I
10.1111/j.1751-908X.2005.tb00656.x
中图分类号
P3 [地球物理学]; P59 [地球化学];
学科分类号
0708 ; 070902 ;
摘要
We present a multi-element technique for the simultaneous determination of twelve trace elements in geological materials by combined isotope dilution (ID) sector field inductively coupled plasma-mass spectrometry (SF-ICP-MS) following simple sample digestion. in addition, the concentrations of fourteen other trace elements have been obtained using the ID determined elements as internal standards. This method combines the advantages of ID (high precision and accuracy) with those of SF-ICP-MS (multi-element capability, fast sample processing without element separation) and overcomes the most prevailing drawbacks of ICP-MS (matrix effects and drift in sensitivity). Trace element concentration data for BHVO-1 (n = 5) reproduced to within 1-3% RSD with an accuracy of 1-2% relative to respective literature values for ID values and 2-3% for all other values. We have applied this technique to the analysis of seventeen geological reference materials from the USGS, GSJ and IAG. The sample set also included the new USGS reference glasses BCR-2G, BHVO-2G and BIR-1G, as well as the MPI-DING reference glasses KL2-G and ML3B-G, and NIST SRM 612. Most data agreed within 3-4% with respective literature data. The concentration data for the USGS reference glasses agreed in most cases with respective data of the original rock powder within the combined standard uncertainty of the method (2-3%), except the U concentration of BIR-1G, which showed a three times higher concentration compared to BIR-1.
引用
收藏
页码:63 / 82
页数:20
相关论文
共 50 条
  • [21] Determination of plutonium isotopes in seawater reference materials using isotope-dilution ICP-MS
    Zheng, Jian
    Yamada, Masatoshi
    APPLIED RADIATION AND ISOTOPES, 2012, 70 (09) : 1944 - 1948
  • [22] Boron determination in twenty one silicate rock reference materials by isotope dilution ICP-MS
    D'Orazio, M
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 1999, 23 (01): : 21 - 29
  • [23] NH4F assisted high pressure digestion of geological samples for multi-element analysis by ICP-MS
    Hu, Zhaochu
    Gao, Shan
    Liu, Yongsheng
    Hu, Shenghong
    Zhao, Laishi
    Li, Yanxiang
    Wang, Qi
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2010, 25 (03) : 408 - 413
  • [24] An evaluation of methods for the chemical decomposition of geological materials for trace element determination using ICP-MS
    Yu, ZS
    Robinson, P
    McGoldrick, P
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2001, 25 (2-3): : 199 - 217
  • [25] High precision cadmium isotope analysis of geological reference materials by double spike MC-ICP-MS
    Peng, Huan
    He, Dong
    Guo, Rui
    Liu, Xing
    Belshaw, Nicholas S.
    Zheng, Hongtao
    Hu, Shenghong
    Zhu, Zhenli
    JOURNAL OF ANALYTICAL ATOMIC SPECTROMETRY, 2021, 36 (02) : 390 - 398
  • [26] Laser ablation ICP-MS analysis of geological materials prepared as lithium bordte glasses
    Eggins, SM
    GEOSTANDARDS NEWSLETTER-THE JOURNAL OF GEOSTANDARDS AND GEOANALYSIS, 2003, 27 (02): : 147 - 162
  • [27] ELEMENT XR: Increased linear dynamic detection range sector field ICP-MS for geological applications
    Hamester, M
    Rottmann, L
    Wills, J
    GEOCHIMICA ET COSMOCHIMICA ACTA, 2005, 69 (10) : A797 - A797
  • [28] Copper Isotopic Analysis in Geological and Biological Reference Materials by MC-ICP-MS
    Sullivan, Kaj
    Layton-Matthews, Daniel
    Leybourne, Matthew
    Kidder, James
    Mester, Zoltan
    Yang, Lu
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2020, 44 (02) : 349 - 362
  • [29] Cadmium Isotope Ratios of Standard Solutions and Geological Reference Materials Measured by MC-ICP-MS
    Li, Dandan
    Li, Meng-Lun
    Liu, Wen-Ran
    Qin, Zhen-Zhen
    Liu, Sheng-Ao
    GEOSTANDARDS AND GEOANALYTICAL RESEARCH, 2018, 42 (04) : 593 - 605
  • [30] Determination of selenium in biological materials by isotope dilution analysis with an octapole reaction system ICP-MS
    García Alonso, J.I. (jiga@sauron.quimica.uniovi.es), 1600, Royal Society of Chemistry (18):