Low-cost photoacoustic NO2 trace gas monitoring at the pptV-level

被引:45
|
作者
Rueck, Thomas [1 ,2 ]
Bierl, Rudolf [1 ]
Matysik, Frank-Michael [2 ]
机构
[1] OTH Regensburg, Sensor Applikat Zentrum SappZ, D-93053 Regensburg, Germany
[2] Univ Regensburg, D-93053 Regensburg, Germany
关键词
Photoacoustic spectroscopy; Nitrogen dioxide (NO2); Low-cost (blue diode laser; MEMS microphone) 3D printed cell; pptV-level; BLUE LASER-DIODE; SEMICONDUCTOR-LASER; NITROGEN-DIOXIDE; SPECTROSCOPY; SPECTROMETER; EXCITATION; REGION; CELL; NM;
D O I
10.1016/j.sna.2017.06.036
中图分类号
TM [电工技术]; TN [电子技术、通信技术];
学科分类号
0808 ; 0809 ;
摘要
We present the development and the characterization of a photoacoustic NO2 trace gas detection system. The system is based on the implementation of low-cost components, i.e. a mass-produced blue diode laser and a standard MEMS Microphone which is commonly built into smartphones, for example. An optimized cell design was realized by means of 3D printing. The linearity of the photoacoustic signal dependency on the analyte concentration was verified from 200 ppbV to 100 ppmV NO2. The detection limit (1 sigma) was determined to 33 pptV and the normalized noise equivalent absorption coefficient was calculated to 7.0.10(-10) W cm(-1) Hz(-1/2). The dynamic range of the system was verified to be linear over three magnitudes of order and the sensitivity was calculated to 814 mu V/ppmV. The system was characterized in view of optimal operating parameters, i.e. lock-in time constant tau(LIA) and total mass flow rate, optical performance and signal stability. The mass flow dependend response time of the system was specified to 19 s and an idealized step response to a quasi-Heaviside step function was quantified as a function of tau(LIA). The quality factor of acoustic resonance was determined to 21.9 and an empirical expression regarding acoustic node shifting is provided. The expression takes into account the radius of the resonator pipe and the radius of the hole, which was drilled into the pipe for microphone coupling. Furthermore, we studied the cross-sensitivity of the photoacoustic signal towards H2O and CO2, respectively. (C) 2017 The Authors. Published by Elsevier B.V.
引用
收藏
页码:501 / 509
页数:9
相关论文
共 50 条
  • [21] LOW-COST LEVEL SWITCH
    不详
    CHEMICAL ENGINEER-LONDON, 1993, (537): : 14 - 14
  • [22] Preliminary Design of a Low-cost Water Level Monitoring System for Bridges
    Chaves Abarca, Michael
    Ruiz Barquero, Anibal
    Garita, Cesar
    Ortiz, Giannina
    2018 IEEE 38TH CENTRAL AMERICA AND PANAMA CONVENTION (CONCAPAN XXXVIII), 2018, : 278 - 283
  • [23] LOW-COST REDUCING GAS
    FINNERAN, JA
    WATSON, H
    YARZE, JC
    GREENE, MI
    JOURNAL OF METALS, 1972, 24 (02): : 35 - &
  • [24] Low-cost capacitive sensor for oil-level monitoring in aircraft
    De Palma, Luisa
    Adamo, Francesco
    Attivissimo, Filippo
    De Gioia, Sergio
    Di Nisio, Attilio
    Lanzolla, Anna Maria Lucia
    Scarpetta, Marco
    2022 IEEE INTERNATIONAL INSTRUMENTATION AND MEASUREMENT TECHNOLOGY CONFERENCE (I2MTC 2022), 2022,
  • [25] An automated low-cost monitoring station for suspended sediments and water level
    Silva, Paulo V. R. M.
    James, Robert B.
    Russell, Kathryn L.
    Fletcher, Tim D.
    Gisi, Maria F. S.
    Navratil, Oldrich
    Cherqui, Frederic
    Cossart, Etienne
    HARDWAREX, 2024, 20
  • [26] A LOW-COST GAS MIXER
    BEATTY, PCW
    JOURNAL OF BIOMEDICAL ENGINEERING, 1990, 12 (04): : 345 - 350
  • [27] Calibrations of Low-Cost Air Pollution Monitoring Sensors for CO, NO2, O3, and SO2
    Han, Pengfei
    Mei, Han
    Liu, Di
    Zeng, Ning
    Tang, Xiao
    Wang, Yinghong
    Pan, Yuepeng
    SENSORS, 2021, 21 (01) : 1 - 18
  • [28] Low-cost, portable photoacoustic setup for solid samples
    Rabasovic, Mihailo D.
    Nikolic, Marko G.
    Dramicanin, Miroslav D.
    Franko, Mladen
    Markushev, Dragan D.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2009, 20 (09)
  • [29] Calibration of Low-Cost NO2 Sensors through Environmental Factor Correction
    Miech, Jason A.
    Stanton, Levi
    Gao, Meiling
    Micalizzi, Paolo
    Uebelherr, Joshua
    Herckes, Pierre
    Fraser, Matthew P.
    TOXICS, 2021, 9 (11)
  • [30] Influence of Concept Drift on Metrological Performance of Low-Cost NO2 Sensors
    D'Elia, Gerardo
    Ferro, Matteo
    Sommella, Paolo
    De Vito, Saverio
    Ferlito, Sergio
    D'Auria, Paolo
    Di Francia, Girolamo
    IEEE TRANSACTIONS ON INSTRUMENTATION AND MEASUREMENT, 2022, 71