Performance of X-ray stepper for next-generation lithography

被引:19
|
作者
Fukuda, M [1 ]
Suzuki, M [1 ]
Haga, T [1 ]
Takeuchi, N [1 ]
Morita, H [1 ]
Deguchi, K [1 ]
Taguchi, T [1 ]
Aoyama, H [1 ]
Mitsui, S [1 ]
Matsui, Y [1 ]
机构
[1] Nippon Telegraph & Tel Corp, Telecommun Energy Labs, Atsugi, Kanagawa 2340198, Japan
关键词
proximity X-ray lithography; X-ray stepper; 100-nm pattern; overall overlay accuracy; alignment system; magnification correction;
D O I
10.1143/JJAP.38.7059
中图分类号
O59 [应用物理学];
学科分类号
摘要
X-ray steppers have been developed and improved to the point where they are capable of replicating 100-nm patterns. The alignment system, which employs an optical heterodyne system with two wavelengths, was improved by analyzing and reducing the crosstalk and asymmetry in the alignment optics. The overlay accuracy of the steppers with respect to themselves is better than 20 nm: regardless of the wafer mark depth. A magnification correction method using wafer temperature control and chucking force is implemented on the steppers. We have achieved an overall overlay accuracy of less than 35 nm, which includes the pattern placement error for two masks: etching process distortion, and alignment error. This demonstrates the capability of proximity X-ray lithography to meet the requirements of 100-nm lithography.
引用
收藏
页码:7059 / 7064
页数:6
相关论文
共 50 条
  • [21] An X-ray harmonic separator for next-generation synchrotron X-ray sources and X-ray free-electron lasers
    Inoue, Ichiro
    Osaka, Taito
    Tamasaku, Kenji
    Ohashi, Haruhiko
    Yamazaki, Hiroshi
    Goto, Shunji
    Yabashi, Makina
    JOURNAL OF SYNCHROTRON RADIATION, 2018, 25 : 346 - 353
  • [23] Performance verification of next-generation Si CMOS soft X-ray detector for space applications
    Ogino, Naoki
    Arimoto, Makoto
    Sawano, Tatsuya
    Yonetoku, Daisuke
    Yu, Pang
    Watanabe, Shota
    Hiraga, Junko S.
    Yuhi, Daito
    Hatori, Satoshi
    Kume, Kyo
    Hasegawa, Takashi
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2021, 987
  • [24] High-Performance Next-Generation Perovskite Nanocrystal Scintillator for Nondestructive X-Ray Imaging
    Heo, Jin Hyuck
    Shin, Dong Hee
    Park, Jin Kyoung
    Kim, Do Hun
    Lee, Sang Jin
    Im, Sang Hyuk
    ADVANCED MATERIALS, 2018, 30 (40)
  • [25] DynamiX, numerical tool for design of next-generation x-ray telescopes
    Chauvin, Maxime
    Roques, Jean-Pierre
    APPLIED OPTICS, 2010, 49 (21) : 4077 - 4087
  • [26] Synchrotron radiation - Swiss plan next-generation X-ray source
    Biggin, S
    SCIENCE, 1996, 272 (5261) : 479 - 479
  • [27] Adaptive Grazing Incidence Optics for the Next-Generation of X-Ray Observatories
    Lillie, C.
    Pearson, D.
    Plinta, A.
    Metro, B.
    Lintz, E.
    Shropshire, D.
    Danner, R.
    ADAPTIVE X-RAY OPTICS, 2010, 7803
  • [28] Instrumentation for a next-generation x-ray all-sky monitor
    Peele, AG
    SMALL MISSIONS FOR ENERGETIC ASTROPHYSICS: ULTRAVIOLET TO GAMMA-RAY, 1999, 499 : 135 - 145
  • [29] AN X-RAY STEPPER
    CULLMANN, E
    PROCEEDINGS OF THE SOCIETY OF PHOTO-OPTICAL INSTRUMENTATION ENGINEERS, 1984, 448 : 104 - 107
  • [30] Modular approach to achieving the next-generation X-ray light source
    Biedron, SG
    Milton, SV
    Freund, HP
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION A-ACCELERATORS SPECTROMETERS DETECTORS AND ASSOCIATED EQUIPMENT, 2001, 475 (1-3): : 401 - 406