Risk Factors for Conversion to Cardiopulmonary Bypass During Off-Pump Coronary Artery Bypass Surgery

被引:48
|
作者
Chowdhury, Ritam
White, Darcy
Kilgo, Patrick
Puskas, John D.
Thourani, Vinod H.
Chen, Edward P.
Lattouf, Omar M.
Cooper, William A.
Myung, Richard J.
Guyton, Robert A.
Halkos, Michael E. [1 ]
机构
[1] Emory Univ, Sch Med, MOT, Div Cardiothorac Surg,Clin Res Unit, Atlanta, GA 30308 USA
来源
ANNALS OF THORACIC SURGERY | 2012年 / 93卷 / 06期
关键词
ON-PUMP; OUTCOMES; MORBIDITY; MORTALITY;
D O I
10.1016/j.athoracsur.2012.02.051
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background. Off-pump coronary artery bypass graft (OPCAB) may be associated with improved hospital outcomes compared with on-pump coronary artery bypass graft. However, intraoperative conversion to on-pump coronary artery bypass graft has been associated with adverse outcomes. The purpose of this study was to identify preoperative risk factors for intraoperative conversion in nonemergent patients undergoing isolated OPCAB. Methods. From 2002 to 2010, 8,077 consecutive OPCAB cases were performed at a single US academic center. Of these, 200 (2.5%) required intraoperative conversion. Standard variables from The Society of Thoracic Surgeons database were analyzed. A multivariable logistic model with adjusted odds ratios (OR) and 95% confidence intervals was used to identify independent risk factors for conversion. Adjusted in-hospital and long-term survival between converted and nonconverted patients were determined using multiple logistic regression and Cox proportional hazards regression, respectively. Results. Converted patients had a higher Society of Thoracic Surgeons predicted risk of mortality (2.8% versus 2.1%; p < 0.001). Surgeon identity was the most significant multivariable predictor of conversion. After adjustment for surgeon identity, the following independent risk factors were associated with intraoperative conversion: previous coronary artery bypass graft (OR, 3.43; p = 0.018), congestive heart failure (OR, 1.51), myocardial infarction (OR, 1.86), number of grafts (OR, 1.45), left main disease (OR 1.41), and urgent status (OR, 1.77; all p < 0.05). Conversion to on-pump coronary artery bypass graft was associated with increased in-hospital (OR, 4.8; p < 0.001) and long-term mortality (hazard ratio, 1.65; p < 0.001). Conclusions. Conversion to cardiopulmonary bypass during OPCAB is associated with increased in-hospital and long-term mortality and may be related to surgeon experience. Recognition of the preoperative risk factors associated with an increased risk of conversion may allow for better patient selection and reduce the incidence of intraoperative conversion during OPCAB.
引用
收藏
页码:1936 / 1942
页数:7
相关论文
共 50 条
  • [41] Jugular bulb desaturation during off-pump coronary artery bypass surgery
    Miura, Norikazu
    Yoshitani, Kenji
    Kawaguchi, Masahiko
    Shinzawa, Masahide
    Irie, Tomoya
    Uchida, Osamu
    Ohnishi, Yoshihiko
    Mackensen, G. Burkhard
    JOURNAL OF ANESTHESIA, 2009, 23 (04) : 477 - 482
  • [42] Systemic air embolism during off-pump coronary artery bypass surgery
    Lombard, FW
    Welsby, IJ
    Booth, JV
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2003, 17 (03) : 403 - 404
  • [43] Hemodynamic changes during off-pump coronary artery bypass graft surgery
    D'Ancona, G
    Karamanoukian, H
    Bergsland, J
    Salerno, T
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2000, 14 (02) : 235 - 236
  • [44] Failure of argatroban anticoagulation during off-pump coronary artery bypass surgery
    Cannon, MA
    Butterworth, J
    Riley, RD
    Hyland, JM
    ANNALS OF THORACIC SURGERY, 2004, 77 (02): : 711 - 713
  • [45] Anaesthesia for off-pump coronary artery bypass grafting surgery
    Alston, R. Peter
    ANAESTHESIA AND INTENSIVE CARE MEDICINE, 2009, 10 (09): : 421 - 423
  • [46] Off-pump coronary artery bypass surgery: newer understanding
    Kunhi, Moosa
    Badami, Harish
    Rajan, Madhu
    Nebhu, M. S.
    Jose, Reshmi L.
    Dr Sandhya
    CIRCULATION, 2012, 125 (19) : E668 - E668
  • [47] Reduction of ischemia during off-pump coronary artery bypass graft surgery
    Kwak, YL
    JOURNAL OF CARDIOTHORACIC AND VASCULAR ANESTHESIA, 2005, 19 (05) : 667 - 677
  • [48] Conversion During Off-pump Coronary Artery Bypass Graft Surgery: A Case-control Study
    Chakravarthy, Murali
    Prabhakumar, Dattatreya
    Patil, T. A.
    George, Antony
    Jawali, Vivek
    ANNALS OF CARDIAC ANAESTHESIA, 2019, 22 (01) : 18 - 23
  • [49] On-pump versus off-pump coronary artery bypass: independent risk factors and off-pump graft patency
    Lund, O
    Christensen, J
    Holme, S
    Fruergaard, K
    Olesen, A
    Kassis, E
    Abildgaard, U
    EUROPEAN JOURNAL OF CARDIO-THORACIC SURGERY, 2001, 20 (05) : 901 - 907
  • [50] Coronary artery surgery: conventional coronary artery bypass grafting versus off-pump coronary artery bypass grafting
    Salzberg, SP
    Adams, DH
    Filsoufi, F
    CURRENT OPINION IN CARDIOLOGY, 2005, 20 (06) : 509 - 516