Realization of integral 3-dimensional image using fabricated tunable liquid lens array

被引:2
|
作者
Lee, Muyoung [1 ]
Kim, Junoh [1 ]
Kim, Cheol Joong [1 ]
Lee, Jin Su [1 ]
Won, Yong Hyub [1 ]
机构
[1] Korea Adv Inst Sci & Technol, Dept Elect Engn, Photon CODE Res Lab, Taejon 305701, South Korea
来源
MICROFLUIDICS, BIOMEMS, AND MEDICAL MICROSYSTEMS XIII | 2015年 / 9320卷
关键词
Electrowetting; Liquid lens array; Integral imaging; DISPLAY;
D O I
10.1117/12.2078296
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Electrowetting has been widely studied for various optical applications such as optical switch, sensor, prism, and display. In this study, vari-focal liquid lens array is developed using electrowetting principle to construct integral 3-dimensional imaging. The electrowetting principle that changes the surface tension by applying voltage has several advantages to realize active optical device such as fast response time, low electrical consumption, and no mechanical moving parts. Two immiscible liquids that are water and oil are used for forming lens. By applying a voltage to the water, the focal length of the lens could be tuned as changing contact angle of water. The fabricated electrowetting vari-focal liquid lens array has 1mm diameter spherical lens shape that has 1.6mm distance between each lens. The number of lenses on the panel is 23x23 and the focal length of the lens array is simultaneously tuned from -125 to 110 diopters depending on the applied voltage. The fabricated lens array is implemented to integral 3-dimensional imaging. A 3D object is reconstructed by fabricated liquid lens array with 23x23 elemental images that are generated by 3D max tools. When liquid lens array is tuned as convex state. From vari-focal liquid lens array implemented integral imaging system, we expect that depth enhanced integral imaging can be realized in the near future.
引用
收藏
页数:7
相关论文
共 50 条
  • [21] Three-dimensional photon counting integral imaging using moving array lens technique
    Cho, Myungjin
    Javidi, Bahram
    OPTICS LETTERS, 2012, 37 (09) : 1487 - 1489
  • [22] ADVANCES IN 3-DIMENSIONAL MAGNETOTELLURIC MODELING USING INTEGRAL-EQUATIONS
    WANNAMAKER, PE
    GEOPHYSICS, 1991, 56 (11) : 1716 - 1728
  • [23] Integral imaging system using an adaptive lens array
    Song, Min-Ho
    Jeong, Ji-Seong
    Erdenebat, Munkh-Uchral
    Kwon, Ki-Chul
    Kim, Nam
    Yoo, Kwan-Hee
    APPLIED OPTICS, 2016, 55 (23) : 6399 - 6403
  • [24] A New Image Segmentation Method Based On 3-Dimensional Entropic Thresholding Using a 3-Dimensional (GLLALE) Histogram
    AlSaeed, Duaa H.
    Bouridane, Ahmed
    ElZaart, Ali
    21ST INTERNATIONAL CONFERENCE ON SYSTEMS, SIGNALS AND IMAGE PROCESSING (IWSSIP 2014), 2014, : 235 - 238
  • [25] 3-DIMENSIONAL ELECTROMAGNETIC LENS WITH FORCED PROPAGATION
    REBOUL, JP
    POMOT, C
    MUNIER, J
    COMPTES RENDUS HEBDOMADAIRES DES SEANCES DE L ACADEMIE DES SCIENCES SERIE B, 1967, 265 (18): : 957 - &
  • [26] A METHOD FOR 3-DIMENSIONAL EVALUATION OF THE CRYSTALLINE LENS
    SASAKI, K
    SAKAMOTO, Y
    MIZUNO, T
    KOJIMA, M
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 1995, 36 (04) : S803 - S803
  • [27] 3-DIMENSIONAL ULTRASTRUCTURE OF HUMAN LENS FIBERS
    WILLEKENS, B
    VRENSEN, G
    OPHTHALMIC RESEARCH, 1983, 15 (01) : 59 - 60
  • [28] Re-Calibration and Lens Array Area Detection for Accurate Extraction of Elemental Image Array in Three-Dimensional Integral Imaging
    Jeong, Hyeonah
    Lee, Eunsu
    Yoo, Hoon
    APPLIED SCIENCES-BASEL, 2022, 12 (18):
  • [29] Fabrication of 3-dimensional microstructures using dynamic image projection
    Choi, J. W.
    Ha, Y. M.
    Choi, K. H.
    Lee, S. H.
    PROGRESS OF PRECISION ENGINEERING AND NANO TECHNOLOGY, 2007, 339 : 473 - +
  • [30] Restoration for ultrasonic 3-dimensional image using Boltzmann Machines
    Yamagiwa, M
    Yoneyama, M
    ISPA 2003: PROCEEDINGS OF THE 3RD INTERNATIONAL SYMPOSIUM ON IMAGE AND SIGNAL PROCESSING AND ANALYSIS, PTS 1 AND 2, 2003, : 946 - 951