Feasibility of Deep Learning-Based PET/MR Attenuation Correction in the Pelvis Using Only Diagnostic MR Images

被引:43
|
作者
Bradshaw, Tyler J. [1 ]
Zhao, Gengyan [2 ]
Jang, Hyungseok [3 ]
Liu, Fang [1 ]
McMillan, Alan B. [1 ]
机构
[1] Univ Wisconsin, Sch Med & Publ Hlth, Dept Radiol, Madison, WI 53706 USA
[2] Univ Wisconsin, Sch Med & Publ Hlth, Dept Med Phys, Madison, WI 53706 USA
[3] Univ Calif San Diego, Dept Radiol, San Diego, CA 92103 USA
基金
美国国家卫生研究院;
关键词
PET/MR; attenuation correction; deep learning; QUANTITATIVE-EVALUATION; CT IMAGES; SEGMENTATION; GENERATION; TIME;
D O I
10.18383/j.tom.2018.00016
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
This study evaluated the feasibility of using only diagnostically relevant magnetic resonance (MR) images together with deep learning for positron emission tomography (PET)/MR attenuation correction (deepMRAC) in the pelvis. Such an approach could eliminate dedicated MRAC sequences that have limited diagnostic utility but can substantially lengthen acquisition times for multibed position scans. We used axial T2 and T1 LAVA Flex magnetic resonance imaging images that were acquired for diagnostic purposes as inputs to a 3D deep convolutional neural network. The network was trained to produce a discretized (air, water, fat, and bone) substitute computed tomography (CT) (CTsub). Discretized (CTref-discrete) and continuously valued (CTref) reference CT images were created to serve as ground truth for network training and attenuation correction, respectively. Training was performed with data from 12 subjects. CTsub, CTref, and the system MRAC were used for PET/MR attenuation correction, and quantitative PET values of the resulting images were compared in 6 test subjects. Overall, the network produced CTsub with Dice coefficients of 0.79 +/- 0.03 for cortical bone, 0.98 +/- 0.01 for soft tissue (fat: 0.94 +/- 0.0; water: 0.88 +/- 0.02), and 0.49 +/- 0.17 for bowel gas when compared with CTref-discrete. The root mean square error of the whole PET image was 4.9% by using deepMRAC and 11.6% by using the system MRAC. In evaluating 16 soft tissue lesions, the distribution of errors for maximum standardized uptake value was significantly narrower using deepMRAC (-1.0% +/- 1.3%) than using system MRAC method (0.0% +/- 6.4%) according to the Brown-Forsy the test (P < .05). These results indicate that improved PET/MR attenuation correction can be achieved in the pelvis using only diagnostically relevant MR images.
引用
收藏
页码:138 / 147
页数:10
相关论文
共 50 条
  • [21] Automated quantification of brain PET in PET/CT using deep learning-based CT-to-MR translation: a feasibility study
    Kim, Daesung
    Choo, Kyobin
    Lee, Sangwon
    Kang, Seongjin
    Yun, Mijin
    Yang, Jaewon
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2025,
  • [22] Deep learning-based segmentation of the placenta and uterus on MR images
    Shahedi, Maysam
    Spong, Catherine Y.
    Dormer, James D.
    Do, Quyen N.
    Xi, Yin
    Lewis, Matthew A.
    Herrera, Christina
    Madhuranthakam, Ananth J.
    Twickler, Diane M.
    Fei, Baowei
    JOURNAL OF MEDICAL IMAGING, 2021, 8 (05)
  • [23] Evaluation of attenuation correction in cardiac PET using PET/MR
    Lau, Jeffrey M. C.
    Laforest, R.
    Sotoudeh, H.
    Nie, X.
    Sharma, S.
    McConathy, J.
    Novak, E.
    Priatna, A.
    Gropler, R. J.
    Woodard, P. K.
    JOURNAL OF NUCLEAR CARDIOLOGY, 2017, 24 (03) : 839 - 846
  • [24] Evaluation of attenuation correction in cardiac PET using PET/MR
    Jeffrey M. C. Lau
    R. Laforest
    H. Sotoudeh
    X. Nie
    S. Sharma
    J. McConathy
    E. Novak
    A. Priatna
    R. J. Gropler
    P. K. Woodard
    Journal of Nuclear Cardiology, 2017, 24 : 839 - 846
  • [25] A Deep Learning-based correction to EPID dosimetry for attenuation and scatter in the Unity MR-Linac system
    Olaciregui-Ruiz, Igor
    Torres-Xirau, Iban
    Teuwen, Jonas
    van der Heide, Uulke A.
    Mans, Anton
    PHYSICA MEDICA-EUROPEAN JOURNAL OF MEDICAL PHYSICS, 2020, 71 : 124 - 131
  • [26] Attenuation Correction for Amyloid PET Imaging Using Deep Learning Based on 3D UTE/Multi-Echo Dixon MR images
    Gong, Kuang
    Han, Paul
    Johnson, Keith
    El Fakhri, Georges
    Ma, Chao
    Li, Quanzheng
    JOURNAL OF NUCLEAR MEDICINE, 2020, 61
  • [27] Alternative methods for attenuation correction for PET images in MR-PET scanners
    Kops, Elena Rota
    Herzog, Hans
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 4327 - 4330
  • [28] MR based attenuation correction and μ map production in PET/MR breast imaging
    Sulikowski, Amy
    Leonard, Scott
    Gruchot, Michelle
    Riehle, Lisa
    Dillehay, Gary
    JOURNAL OF NUCLEAR MEDICINE, 2018, 59
  • [29] An Automatic Deep Learning-Based Workflow for Glioblastoma Survival Prediction Using Preoperative Multimodal MR Images: A Feasibility Study
    Fu, Jie
    Singhrao, Kamal
    Zhong, Xinran
    Gao, Yu
    Qi, Sharon X.
    Yang, Yingli
    Ruan, Dan
    Lewis, John H.
    ADVANCES IN RADIATION ONCOLOGY, 2021, 6 (05)
  • [30] Influence of Bones and Constant Attenuation Factors in PET/CT: Learning for MR-based Attenuation Correction in Whole-Body MR/PET
    Martinez-Moeller, A.
    Souvatzoglou, M.
    Bundschuh, R. A.
    Delso, G.
    Ziegler, S. I.
    Navab, N.
    Schwaiger, M.
    Nekolla, S. G.
    EUROPEAN JOURNAL OF NUCLEAR MEDICINE AND MOLECULAR IMAGING, 2008, 35 : S193 - S194