Influence of aspect ratio of tunnel on smoke temperature distribution under ceiling in near field of fire source

被引:96
|
作者
Ji, Jie [1 ,2 ]
Bi, Yubo [1 ]
Venkatasubbaiah, Kondapalli [3 ]
Li, Kaiyuan [4 ]
机构
[1] Univ Sci & Technol China, State Key Lab Fire Sci, Hefei 230026, Anhui, Peoples R China
[2] Univ Sci & Technol China, Inst Adv Technol, Hefei 230088, Anhui, Peoples R China
[3] Indian Inst Technol Hyderabad, Dept Mech Engn, Hyderabad 502205, Andhra Pradesh, India
[4] Aalto Univ, Dept Civil & Struct Engn, Espoo 02150, Finland
基金
中国国家自然科学基金;
关键词
Tunnel fire; Tunnel width; Mass loss rate; Smoke temperature; Pool fire; HEAT RELEASE RATE; LONGITUDINAL VENTILATION; GAS TEMPERATURES; BURNING RATE; VELOCITY; FLOW;
D O I
10.1016/j.applthermaleng.2016.06.086
中图分类号
O414.1 [热力学];
学科分类号
摘要
Former studies usually used model tunnels with fixed width while in reality the tunnel width can be different between different tunnels. In the current study, a set of small scale experiments were conducted using a model tunnel with adjustable width. The influences of tunnel width on mass loss rate, maximum smoke temperature and temperature distributions under the ceiling were investigated. Results show that under the current experimental conditions, the tunnel width has little influence on the mass loss rate and maximum smoke temperature under the ceiling. However, tunnel width significantly affects the smoke temperature distribution. The smoke temperature under the ceiling, decays more slowly at both longitudinal and transverse directions as tunnel width decreases. Empirical models are developed for both longitudinal and transverse temperature distributions which take into account the effects of tunnel width and dimensionless heat release rate. The models include exponential type functions. The index of the exponential function is proportional to the dimensionless heat release rate to the power of n. The value of n is 0.4 for longitudinal distribution and 0.5 for transverse distribution. (C) 2016 Elsevier Ltd. All rights reserved.
引用
收藏
页码:1094 / 1102
页数:9
相关论文
共 50 条
  • [21] Numerical study on the smoke temperature distribution beneath the ceiling of a single-ended sealing tunnel under the condition of double fire sources
    Ma, Qiuju
    Chen, Jianhua
    You, Jingfeng
    He, Ya
    Zhang, Zhaokun
    THERMAL SCIENCE AND ENGINEERING PROGRESS, 2024, 52
  • [22] Water spray effects on fire smoke temperature distribution beneath a symmetrical V-shaped tunnel ceiling
    Wang, Jie
    Gao, Dongmei
    Kong, Xiaowei
    Jiang, Xuepeng
    Lu, Kaihua
    CASE STUDIES IN THERMAL ENGINEERING, 2023, 51
  • [23] Ceiling temperature distribution and smoke diffusion in tunnel fires with natural ventilation
    Kashef, Ahmed
    Yuan, Zhongyuan
    Lei, Bo
    FIRE SAFETY JOURNAL, 2013, 62 : 249 - 255
  • [24] Experimental investigation of tunnel temperature field and smoke spread under the influence of a slow moving train with a fire in the carriage
    Zhang, Zhiqiang
    Tan, Yinjun
    Hong, Runlin
    Zhao, Yu
    Zhang, Heng
    Zhang, Yuchun
    Li, Zhisheng
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 131
  • [25] Study on the maximum ceiling temperature and downstream temperature distribution in inclined tunnel fire
    Sun, Chaopeng
    Weng, Miaocheng
    Liu, Fang
    Yang, Haoran
    Zhu, Xinyi
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 153
  • [26] Experimental investigation on the ceiling flame impingement and temperature distribution in tunnel with varying widths and fire source locations
    Yan, Wenhao
    An, Hongsheng
    Li, Chenguang
    Gao, Zihe
    ENERGY, 2024, 312
  • [27] Effect of train fire location on maximum smoke temperature beneath the subway tunnel ceiling
    Cong, Wei
    Shi, Long
    Shi, Zhicheng
    Peng, Min
    Yang, Hui
    Zhang, Shaogang
    Cheng, Xudong
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2020, 97 (97)
  • [28] Experimental study on transverse fire source and blockage locations influence on tunnel fire temperature distribution
    Li, Linjie
    Wang, Zhen
    Wu, Zhaoguo
    Huang, Huixian
    Zhang, Haibing
    Gao, Zihe
    CASE STUDIES IN THERMAL ENGINEERING, 2024, 61
  • [29] Experimental study on temperature distribution beneath tunnel ceiling under the condition of transverse double fire sources
    Qiu, D. Z.
    Yang, J.
    Liu, C. X.
    Zheng, Y. H.
    Zheng, J. H.
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2023, 132
  • [30] Inclination Effects on Temperature Distribution of Fire Smoke for Highway Tunnel
    Jianwei Cheng
    Zui Wang
    Fangyuan Liu
    Chang Qi
    Iranian Journal of Science and Technology, Transactions of Civil Engineering, 2021, 45 : 2817 - 2830