Multi-Parametric Standardization of Fluorescence Imaging Systems Based on a Composite Phantom

被引:20
|
作者
Gorpas, Dimitris [1 ,2 ]
Koch, Maximilian [1 ,2 ]
Anastasopoulou, Maria [1 ,2 ]
Bozhko, Dmitry [1 ,2 ]
Klemm, Uwe [1 ,2 ]
Nieberler, Markus [3 ]
Ntziachristos, Vasilis [2 ,4 ]
机构
[1] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, Munich, Germany
[2] Tech Univ Munich, Chair Biol Imaging & TranslaTUM, Munich, Germany
[3] Tech Univ Munich, Univ Hosp Rechts Isar, Dept Oral & Maxillofacial Surg, Munich, Germany
[4] Helmholtz Zentrum Munchen, Inst Biol & Med Imaging, D-85764 Neuherberg, Germany
关键词
Fluorescence molecular imaging; composite phantom; standardization; benchmarking; data referencing;
D O I
10.1109/TBME.2019.2910733
中图分类号
R318 [生物医学工程];
学科分类号
0831 ;
摘要
Objective: Fluorescence molecular imaging (FMI) has emerged as a promising tool for surgical guidance in oncology, with one of the few remaining challenges being the ability to offer quality control and data referencing. This paper investigates the use of a novel composite phantom to correct and benchmark FMI systems. Methods: This paper extends on previous work by describing a phantom design that can provide a more complete assessment of FMI systems through quantification of dynamic range and determination of spatial illumination patterns for both reflectance and fluorescence imaging. Various performance metrics are combined into a robust and descriptive "system benchmarking score," enabling not only the comprehensive comparison of different systems, but also for the first time, correction of the acquired data. Results: We show that systems developed for targeted fluorescence imaging can achieve benchmarking scores of up to 70%, while clinically available systems optimized for indocyanine green are limited to 50%, mostly due to greater leakage of ambient and excitation illumination and lower resolution. The image uniformity can also be approximated and employed for image flat-fielding, an important milestone toward data referencing. In addition, we demonstrate composite phantom use in assessing the performance of a surgical microscope and of a raster-scan imaging system. Conclusion: Our results suggest that the new phantom has the potential to support high-fidelity FMI through benchmarking and image correction. Significance: Standardization of the FMI is a necessary process for establishing good imaging practices in clinical environments and for enabling high-fidelity imaging across patients and multi-center imaging studies.
引用
收藏
页码:185 / 192
页数:8
相关论文
共 50 条
  • [31] Platinum complexes for multi-parametric assays using microarray systems
    Gonzalez, Maria
    Bartolome, Raquel
    Matarraz, Sergio
    Rodriguez-Fernandez, Emilio
    Manzano, Juan L.
    Perez-Andres, Martin
    Orfao, Alberto
    Fuentes, Manuel
    Criado, Julio J.
    JOURNAL OF INORGANIC BIOCHEMISTRY, 2012, 106 (01) : 43 - 45
  • [32] Structure of volcano plumbing systems: A review of multi-parametric effects
    Tibaldi, Alessandro
    JOURNAL OF VOLCANOLOGY AND GEOTHERMAL RESEARCH, 2015, 298 : 85 - 135
  • [33] On multi-parametric programming and its applications in process systems engineering
    Oberdieck, Richard
    Diangelakis, Nikolaos A.
    Nascu, Ioana
    Papathanasiou, Maria M.
    Sun, Muxin
    Auraamidou, Styliani
    Pistikopoulos, Efstratios N.
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2016, 116 : 61 - 82
  • [34] Title: Multi-Parametric MRI As a Composite Biomarker for Nash and Nash with Fibrosis
    Mckay, Andy
    Dennis, Andrea
    Kelly, Matthew
    Fallowfield, Jonathan Andrew
    Hirschfield, Gideon
    Neubauer, Stefan
    Banerjee, Rajarshi
    HEPATOLOGY, 2018, 68 : 954A - 955A
  • [35] A multi-parametric recursive continuation method for nonlinear dynamical systems
    Grenat, C.
    Baguet, S.
    Lamarque, C-H.
    Dufour, R.
    MECHANICAL SYSTEMS AND SIGNAL PROCESSING, 2019, 127 : 276 - 289
  • [36] The Prognosis Prediction of GBM Based on High-risk Subregion and Multi-parametric MR Imaging
    Lu, Di
    Zhang, Xi
    Xu, Xiaopan
    He, Xiaowei
    Liu, Yang
    THIRD INTERNATIONAL SYMPOSIUM ON IMAGE COMPUTING AND DIGITAL MEDICINE (ISICDM 2019), 2019, : 214 - 217
  • [38] Research on multi-parametric sensors based on multi-mode microfiber
    Dong, Taiji
    Liu, Xu
    Wang, Yunkai
    Gao, Bingkun
    Jiang, Chunlei
    Wang, Xiufang
    OPTOELECTRONICS LETTERS, 2024, 20 (01) : 18 - 22
  • [39] Research on multi-parametric sensors based on multi-mode microfiber
    DONG Taiji
    LIU Xu
    WANG Yunkai
    GAO Bingkun
    JIANG Chunlei
    WANG Xiufang
    Optoelectronics Letters, 2024, 20 (01) : 18 - 22
  • [40] Microfluidic perifusion and imaging device for multi-parametric islet function assessment
    Adeola F. Adewola
    Dongyoung Lee
    Tricia Harvat
    Javeed Mohammed
    David T. Eddington
    Jose Oberholzer
    Yong Wang
    Biomedical Microdevices, 2010, 12 : 409 - 417