Reliability and Reproducibility of Hadamard Encoded Pseudo-Continuous Arterial Spin Labeling in Healthy Elderly

被引:6
|
作者
Neumann, Katja [1 ]
Schidlowski, Martin [2 ,3 ]
Guenther, Matthias [4 ,5 ]
Stoecker, Tony [2 ,6 ]
Duezel, Emrah [1 ,7 ,8 ,9 ]
机构
[1] German Ctr Neurodegenerat Dis DZNE, Magdeburg, Germany
[2] German Ctr Neurodegenerat Dis DZNE, Bonn, Germany
[3] Univ Bonn, Dept Epileptol, Med Ctr, Bonn, Germany
[4] Fraunhofer Inst Digital Med MEVIS, Bremen, Germany
[5] Univ Bremen, MR Imaging & Spect, Bremen, Germany
[6] Univ Bonn, Dept Phys & Astron, Bonn, Germany
[7] Otto von Guericke Univ, Inst Cognit Neurol & Dementia Res, Magdeburg, Germany
[8] UCL, Inst Cognit Neurosci, London, England
[9] Ctr Behav Brain Sci, Magdeburg, Germany
关键词
arterial spin labeling; pCASL; reliability; reproducibility; perfusion; cerebral blood flow; arterial transit time; hadamard encoding; CEREBRAL-BLOOD-FLOW; BOLUS ARRIVAL-TIME; INVERSION; MRI; INFERENCE; MODEL; AGE;
D O I
10.3389/fnins.2021.711898
中图分类号
Q189 [神经科学];
学科分类号
071006 ;
摘要
The perfusion parameters cerebral blood flow (CBF) and arterial transit time (ATT) measured with arterial spin labeling (ASL) magnetic resonance imaging (MRI) provide valuable essentials to assess the integrity of cerebral tissue. Brain perfusion changes, due to aging, an intervention, or neurodegenerative diseases for example, could be investigated in longitudinal ASL studies with reliable ASL sequences. Generally, pseudo-continuous ASL (pCASL) is preferred because of its larger signal-to-noise ratio (SNR) compared to pulsed ASL (PASL) techniques. Available pCASL versions differ regarding their feature details. To date only little is known about the reliability and reproducibility of CBF and ATT measures obtained with the innovative Hadamard encoded pCASL variant, especially if applied on participants in old age. Therefore, we investigated an in-house developed Hadamard encoded pCASL sequence on a group of healthy elderly at two different 3 Tesla Siemens MRI systems (Skyra and mMR Biograph) and evaluated CBF and ATT reliability and reproducibility for several regions-of-interests (ROI). Calculated within-subject coefficients of variation (wsCV) demonstrated an excellent reliability of perfusion measures, whereas ATT appeared to be even more reliable than CBF [e.g., wsCV(CBF) = 2.9% vs. wsCV(ATT) = 2.3% for a gray matter (GM) ROI on Skyra system]. Additionally, a substantial agreement of perfusion values acquired on both MRI systems with an inter-session interval of 78 +/- 17.6 days was shown by high corresponding intra-class correlation (ICC) coefficients [e.g., ICC(CBF) = 0.704 and ICC(ATT) = 0.754 for a GM ROI]. The usability of this novel Hadamard encoded pCASL sequence might improve future follow-up perfusion studies of the aging and/or diseased brain.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] In Vivo Hadamard Encoded Continuous Arterial Spin Labeling (H-CASL)
    Wells, Jack A.
    Lythgoe, Mark F.
    Gadian, David G.
    Ordidge, Roger J.
    Thomas, David L.
    MAGNETIC RESONANCE IN MEDICINE, 2010, 63 (04) : 1111 - 1118
  • [22] Measurement of brain perfusion in newborns: Pulsed arterial spin labeling (PASL) versus pseudo-continuous arterial spin labeling (pCASL)
    Boudes, Elodie
    Gilbert, Guillaume
    Leppert, Ilana Ruth
    Tan, Xianming
    Pike, G. Bruce
    Saint-Martin, Christine
    Wintermark, Pia
    NEUROIMAGE-CLINICAL, 2014, 6 : 126 - 133
  • [23] Real-Time Functional MRI Using Pseudo-Continuous Arterial Spin Labeling
    Hernandez-Garcia, Luis
    Jahanian, Hesamoddin
    Greenwald, Mark K.
    Zubieta, Jon-Kar
    Peltier, Scott J.
    MAGNETIC RESONANCE IN MEDICINE, 2011, 65 (06) : 1570 - 1577
  • [24] Optimisation of pulsed and pseudo-continuous arterial spin labeling MRI techniques: A phantom study
    Yusoff, Norain
    Zukhi, Jihan
    Rusli, Awatif
    Zainon, Rafidah
    10TH INTERNATIONAL SEMINAR ON MEDICAL PHYSICS & 1ST AMDI INTERNATIONAL ONCOLOGY SYMPOSIUM, 2017, 851
  • [25] Cardiac-triggered pseudo-continuous arterial-spin-labeling: A cost-effective scheme to further enhance the reliability of arterial-spin-labeling MRI
    Li, Yang
    Mao, Deng
    Li, Zhiqiang
    Schaer, Michael
    Pillai, Jay J.
    Pipe, James G.
    Lu, Hanzhang
    MAGNETIC RESONANCE IN MEDICINE, 2018, 80 (03) : 969 - 975
  • [26] Optimization of the spatial modulation function of vessel-encoded pseudo-continuous arterial spin labeling and its application to dynamic angiography
    Suzuki, Yuriko
    van Osch, Matthias J. P.
    Fujima, Noriyuki
    Okell, Thomas W.
    MAGNETIC RESONANCE IN MEDICINE, 2019, 81 (01) : 410 - 423
  • [27] Reduction of BOLD interference in pseudo-continuous arterial spin labeling: towards quantitative fMRI
    Warnock, Geoffrey
    Oezbay, Pinar S.
    Kuhn, Felix P.
    Nanz, Daniel
    Buck, Alfred
    Boss, Andreas
    Rossi, Cristina
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2018, 38 (05): : 847 - 856
  • [28] Cerebral Perfusion in Adolescent Major Depression: A Pseudo-Continuous Arterial Spin Labeling Study
    Ho, Tiffany C.
    Wu, Jing
    Shin, David D.
    Yang, Guang
    Banerjee, Dipavo
    Connolly, Colm G.
    Hendren, Robert
    Simmons, Alan G.
    Yang, Tony
    BIOLOGICAL PSYCHIATRY, 2013, 73 (09) : 165S - 165S
  • [29] Cerebral Blood Flow Quantification in Swine Using Pseudo-Continuous Arterial Spin Labeling
    Johnston, Megan E.
    Zheng, Zhenlin
    Maldjian, Joseph A.
    Whitlow, Christopher T.
    Morykwas, Michael J.
    Jung, Youngkyoo
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2013, 38 (05) : 1111 - 1118
  • [30] Simultaneous measurement of brain perfusion and labeling efficiency in a single pseudo-continuous arterial spin labeling scan
    Chen, Zhensen
    Zhao, Xihai
    Zhang, Xingxing
    Guo, Rui
    Teeuwisse, Wouter M.
    Zhang, Bida
    Koken, Peter
    Smink, Jouke
    Yuan, Chun
    van Osch, Matthias J. P.
    MAGNETIC RESONANCE IN MEDICINE, 2018, 79 (04) : 1922 - 1930