The calculation of dose enhancement close to platinum implants for skull radiography

被引:6
|
作者
Cheung, Joel Y. C.
Tang, Fuk-Hay [1 ]
机构
[1] Hong Kong Polytech Univ, Dept Hlth Technol & Informat, Hung Hum, Hong Kong, Peoples R China
[2] Princess Margaret Hosp, Dept Oncol, Hong Kong, Hong Kong, Peoples R China
来源
HEALTH PHYSICS | 2007年 / 93卷 / 04期
关键词
x rays; radiography; Monte Carlo; cancer;
D O I
10.1097/01.HP.0000264450.81683.51
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Materials with high atomic numbers experience the occurrence of the photoelectric effect when they are irradiated by low energy photons. A short range dose enhancement, due to the dominant photoelectric effect, close to platinum implants (Z = 78) in diagnostic radiography cannot be easily measured experimentally. The enhanced dose may increase the risk for adverse health effects from cancer or may damage vital brain structures close to the high atomic number implants. In the present work, Monte Carlo simulation using the LSCAT version of PRESTA EGS4 was employed to investigate the resulting dose enhancements. The results show that the highest estimated dose enhancement of 79% for brain tissues close to platinum implants was calculated for 65 kV x-ray energy and 180% for 120 kV x-ray energy.
引用
收藏
页码:267 / 272
页数:6
相关论文
共 50 条
  • [41] Effect of Photon Incidence Angle On the Accuracy of the Dose Point Kernel Method for Calculation of Gold Nanoparticle-Mediated Intracellular Dose Enhancement
    Jayarathna, S.
    Moktan, H.
    Cho, S. H.
    MEDICAL PHYSICS, 2020, 47 (06) : E374 - E374
  • [42] Effect of Field Angle Setting On Dose Calculation Accuracy in Intensity Modulated Radiation Therapy Plan for Patient with Metal Implants
    Zhou, G.
    Sun, Y. Z.
    Zhao, P. F.
    Xing, P. F.
    Tian, Y.
    MEDICAL PHYSICS, 2019, 46 (06) : E611 - E611
  • [43] Monte-Carlo calculation of dose enhancement effects produced by X-ray to Kovar package
    Guo, H.X.
    Zhang, Y.M.
    Chen, Y.S.
    Zhou, H.
    Gong, J.C.
    Wu, G.R.
    Lin, D.S.
    Han, F.B.
    2001, Atomic Energy Press (21):
  • [44] Patient positioning, target delineation and dose calculation with MV cone-beam CT for patients with metallic implants: Clinical integration
    Aubin, Nni.
    Morin, O.
    Descovich, M.
    Speight, J.
    Gottschalk, A.
    Xia, P.
    Aubry, J.
    Verhey, L.
    Roach, M.
    Pouliot, J.
    INTERNATIONAL JOURNAL OF RADIATION ONCOLOGY BIOLOGY PHYSICS, 2007, 69 (03): : S668 - S669
  • [45] Comparisons of the Dose Calculation Algorithms and the Dosimetric Impact of Titanium Implants in Spinal SBRT Using Three Commercial Treatment Planning Systems
    Liu, C.
    Magnelli, A.
    Cho, Y.
    Angelov, L.
    Balagamwala, E.
    Chao, S.
    Xia, P.
    MEDICAL PHYSICS, 2022, 49 (06) : E967 - E967
  • [46] Simulative calculation of the dose enhancement factor of W-SiO2 and Ta-SiO2 interface
    Mu, W.B.
    Chen, P.X.
    Qiangjiguang Yu Lizishu/High Power Laser and Particle Beams, 2001, 13 (01): : 15 - 18
  • [47] CALCULATION OF DOSE CONVERSION FACTORS FOR POSTERIOR-ANTERIOR CHEST RADIOGRAPHY OF ADULTS WITH A RELATIVELY HIGH-ENERGY X-RAY-SPECTRUM
    SCHULTZ, FW
    GELEIJNS, J
    ZOETELIEF, J
    BRITISH JOURNAL OF RADIOLOGY, 1994, 67 (800): : 775 - 785
  • [48] Accurate characterization of metal implants and human materials using novel proton counting detector for Monte Carlo dose calculation in proton therapy
    Charyyev, Serdar
    Chang, Chih-Wei
    Harms, Joseph
    Oancea, Cristina
    Yoon, S. Tim
    Yang, Xiaofeng
    Zhang, Tiezhi
    Zhou, Jun
    Leng, Shuai
    Lin, Liyong
    MEDICAL IMAGING 2021: PHYSICS OF MEDICAL IMAGING, 2021, 11595
  • [49] Dose distribution close to metal implants in gamma knife radiosurgery: A Monte Carlo study [Med. Phys. 30, 1812-1815 (2003)]
    Cheung, JYC
    Yu, KN
    MEDICAL PHYSICS, 2005, 32 (05) : 1448 - 1449
  • [50] Monte-Carlo calculation of X-ray dose enhancement factor nearby high Z metal connected interface
    Mu, Wei-Bing
    Chen, Pan-Xun
    Wuli Xuebao/Acta Physica Sinica, 2001, 50 (02):