Volar locking plate versus percutaneous fixation for the treatment of distal radial fractures: a meta-analysis of randomized controlled trials

被引:0
|
作者
Shen, Longxiang [1 ]
Wen, Mengni [2 ,3 ]
Wang, Feiyan [2 ,3 ]
Ding, Jian [1 ]
Luo, Congfeng [1 ]
Zhao, Gang [2 ,3 ]
机构
[1] Shanghai Jiao Tong Univ, Peoples Hosp 6, Dept Orthoped Surg, 600 Yishan Rd, Shanghai 200233, Peoples R China
[2] Shanghai Jiao Tong Univ, Peoples Hosp 6, Dept Emergency, 600 Yishan Rd, Shanghai 200233, Peoples R China
[3] Shanghai Jiao Tong Univ, Peoples Hosp 6, Ctr Trauma, 600 Yishan Rd, Shanghai 200233, Peoples R China
基金
中国国家自然科学基金;
关键词
Volar locking plate; distal radial fractures; percutaneous fixation; meta-analysis; DORSALLY DISPLACED FRACTURE; K-WIRE FIXATION; KIRSCHNER WIRES; FUNCTIONAL OUTCOMES; INTERNAL-FIXATION; OSTEOSYNTHESIS; COMPLICATIONS; OLDER; AGE;
D O I
暂无
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
Background: Although operative fixation with a volar locking plate is becoming increasingly popular for treatment of distal radius fractures, it is not clear whether it is superior to other conventional treatment methods such as percutaneous fixation with Kirschner wires. The present meta-analysis compared the effects of internal fixation with volar locking plates and percutaneous fixation for the treatment of distal radius fractures. Methods: A literature search was performed without language restrictions and all randomized controlled studies comparing the effects of volar locking plates and percutaneous fixation for the treatment of distal radial fractures were included. Data of function scores, range of motion, grip strength, radiographic results, and complications were pooled and analyzed with a standard meta-analytical method. Results: Seven studies in seven publications were included. Pooled data indicated that there were no significant differences in Patient-Related Wrist Evaluation (PRWE) and Disabilities of the Arm, Shoulder, and Hand (DASH) scores between the two treatment methods postoperatively. Fixation with volar locking plates took significantly longer than percutaneous fixation. There was a significant difference in supination and grip strength favoring volar locking plate fixation at 3 and 6 months but not at >= 12 months, postoperatively. The final complication rates were similar in the two treatment groups. Conclusion: In the management of distal radius fractures, volar locking plate and percutaneous fixation yielded similar outcomes, while the former had the advantage of supination and grip strength in the early stage postoperatively. Percutaneous fixation was quicker to perform than volar locking plate fixation.
引用
收藏
页码:7780 / 7793
页数:14
相关论文
共 50 条
  • [21] COMPLICATIONS ASSOCIATED WITH VOLAR LOCKING PLATE FIXATION OF DISTAL RADIAL FRACTURES
    Alter, Todd H.
    Ilyas, Asif M.
    JBJS REVIEWS, 2018, 6 (10) : E7
  • [22] TREATMENT OF DISTAL RADIAL FRACTURES BY OPEN REDUCTION AND INTERNAL FIXATION WITH A VOLAR LOCKING PLATE
    Mauser, Nathan S.
    Benoit, Michel Y.
    Morrell, Nathan T.
    Shafritz, Adam B.
    JBJS ESSENTIAL SURGICAL TECHNIQUES, 2016, 6 (03):
  • [23] Is volar locking plate superior to external fixation for distal radius fractures? A comprehensive meta-analysis
    Wang, Jie
    Lu, Yandong
    Cui, Yujie
    Wei, Xuelei
    Sun, Jie
    ACTA ORTHOPAEDICA ET TRAUMATOLOGICA TURCICA, 2018, 52 (05) : 334 - 342
  • [24] Comparison between Volar Locking Plate and Kirschner Wire Fixation for Unstable Distal Radius Fracture: A Meta-Analysis of Randomized Controlled Trials
    Tariq, Muhammad A.
    Ali, Uzair
    Uddin, Qazi S.
    Altaf, Zahabia
    Mohiuddin, Ashar
    JOURNAL OF WRIST SURGERY, 2024, 13 (05) : 469 - 480
  • [25] A Meta-analysis of Studies of Volar Locking Plate Fixation of Distal Radius Fractures: Conventional versus Minimally Invasive Plate Osteosynthesis
    Lee, Dong-Yeong
    Park, Young-Jin
    Park, Jin-Sung
    CLINICS IN ORTHOPEDIC SURGERY, 2019, 11 (02) : 208 - 219
  • [26] Intramedullary fixation versus plate fixation in the treatment of midshaft clavicle fractures: a meta-analysis of randomized controlled trials
    Lu, Minpeng
    Qiu, Hao
    Liu, Yuting
    Dong, Jing
    Jiang, Lingfang
    FRONTIERS IN SURGERY, 2024, 10
  • [27] Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires
    Shuang-Le Zong
    Shi-Lian Kan
    Li-Xin Su
    Bin Wang
    Journal of Orthopaedic Surgery and Research, 10
  • [28] Meta-analysis for dorsally displaced distal radius fracture fixation: volar locking plate versus percutaneous Kirschner wires
    Zong, Shuang-Le
    Kan, Shi-Lian
    Su, Li-Xin
    Wang, Bin
    JOURNAL OF ORTHOPAEDIC SURGERY AND RESEARCH, 2015, 10
  • [29] Functional outcome in patients with unstable distal radius fractures, volar locking plate versus external fixation: a meta-analysis
    Walenkamp, Monique M. J.
    Bentohami, Abdelali
    Beerekamp, M. Suzan H.
    Peters, Rolf W.
    van der Heiden, Remy
    Goslings, J. Carel
    Schep, Niels W. L.
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2013, 8 (02) : 67 - 75
  • [30] Polyaxial versus uniaxial volar locking plate for distal radial fractures
    Al-Mouazzen, Louay
    Chou, Daud Tai Shan
    Kyriakopoulos, Georgios
    Hambidge, John
    JOURNAL OF ORTHOPAEDIC SURGERY, 2014, 22 (01) : 9 - 12