Experimental study of the performance of single-band air curtains for a multi-deck refrigerated display cabinet

被引:55
|
作者
Chen, YG [1 ]
Yuan, XL [1 ]
机构
[1] Xian Jiaotong Univ, Dept Refrigerat & Cryogen Engn, Sch Energy & Power Engn, Xian 710049, Peoples R China
关键词
air curtains; refrigerated display cabinets; experimental study;
D O I
10.1016/j.jfoodeng.2004.08.016
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
Experiments were conducted to study the effects of several important factors on the performance of a refrigerated display cabinet, including ambient air temperature, indoor relative humidity, ambient air flow, air supply velocity, air flow from perforated back panels and night covers. Both inside temperature distribution and heat load were investigated. Furthermore, the thermal entrainment factor is correlated with Reynolds number and Richardson number. The results show the thermal entrainment tends to increase with increasing momentum force but decrease when the gravitational force is dominant. (c) 2004 Elsevier Ltd. All rights reserved.
引用
收藏
页码:261 / 267
页数:7
相关论文
共 50 条
  • [21] Experimental investigation of the performance of cool storage shelf for vertical open refrigerated display cabinet
    Wu XueHong
    Li WeiPing
    Wang Yanling
    Chang ZhiJuan
    Wang ChunXu
    Ding Chang
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2017, 110 : 789 - 795
  • [22] Air-flow distribution simulation and experimental analysis of a new testing room for refrigerated display cabinet
    Huang, Chao
    Wang, Fang
    Wu, Zhimin
    Guo, Chao
    ADVANCES IN POWER AND ELECTRICAL ENGINEERING, PTS 1 AND 2, 2013, 614-615 : 701 - 706
  • [23] Air-flow distribution simulation and experimental analysis of a new testing room for refrigerated display cabinet
    College of Power Engineering, University of Shanghai for Science and Technology, Shanghai 200093, China
    Shanghai Ligong Daxue Xuebao, 2007, 4 (353-357):
  • [24] Investigation of the effects of fan control technique on energy consumption in industrial refrigerated display cabinet: An experimental study
    Kosan, Meltem
    Dilber, Yagiz
    Erten, Suleyman
    Bahar, Elif Merve
    Erdogmus, Fatma Nur
    Aktas, Mustafa
    Oder, Melis
    PROCEEDINGS OF THE INSTITUTION OF MECHANICAL ENGINEERS PART E-JOURNAL OF PROCESS MECHANICAL ENGINEERING, 2024, 238 (01) : 227 - 239
  • [25] The impact of geometric structure and flow arrangement on the performance of CO2 evaporators in multi-deck medium temperature display cabinets
    Ge, Y. T.
    Tassou, S. A.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2012, 35 (01): : 142 - 149
  • [26] A Comparative Study of the Effect of Initial Turbulence on the Performance of an Open Vertical Refrigerated Multi-Deck-A Numerical Study and its Experimental Validation
    Chen, Y. F.
    Lin, H. W.
    Hsieh, W. D.
    Lin, J. Y.
    Wang, C. C.
    ASHRAE TRANSACTIONS 2009, VOL 115, PT 2, 2009, 115 : 463 - 470
  • [27] Experimental Study on the Influences of Air Flow in an Integral Hydrocarbon Display Cabinet to its Temperature and Energy Performances
    Suamir, I. N.
    Arsana, M. E.
    Tsamos, K. M.
    INTERNATIONAL CONFERENCE ON MECHANICAL ENGINEERING RESEARCH AND APPLICATION, 2019, 494
  • [28] Application of artificial intelligence models for assessing the performance of closed vertical refrigerated display cabinet- A comparative study of different operating scenarios
    Priyadarshi, Gaurav
    Hoang, Hong-Minh
    Hunlede, Romuald
    Paviet-Salomon, Yvanne
    Delahaye, Anthony
    Naik, Bukke Kiran
    ENGINEERING APPLICATIONS OF ARTIFICIAL INTELLIGENCE, 2025, 147
  • [29] A multi-scale approach for refrigerated display cabinet coupled with supermarket HVAC system-Part II: The performance of VORDC and energy consumption analysis
    Wu, XueHong
    Chang, ZhiJuan
    Zhao, XingLi
    Li, WeiPing
    Lu, YanLi
    Yuan, Pei
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2015, 87 : 685 - 692
  • [30] SELF CONTAINED WATER CONDENSED REFRIGERATED DISPLAY CABINET: EXPERIMENTAL DATA ANALYSIS OF A CARBON DIOXIDE UNIT, WITH COMPARISON OF SYSTEM PERFORMANCE EFFICIENCY AND ENVIRONMENTAL IMPACT
    Orlandi, Maurizio
    Sampietro, Andrea
    Mazzola, Daniele
    12TH IIR GUSTAV LORENTZEN NATURAL WORKING FLUIDS CONFERENCE, 2016, : 535 - 542