Dexamethasone normalizes brain tumor hemodynamics as indicated by dynamic susceptibility contrast MRI perfusion parameters

被引:12
|
作者
Quarles, CC
Krouwer, HGJ
Rand, SD
Schmainda, KM
机构
[1] Med Coll Wisconsin, Dept Biophys, Milwaukee, WI 53226 USA
[2] Med Coll Wisconsin, Dept Neurol, Milwaukee, WI 53226 USA
[3] Med Coll Wisconsin, Dept Neurosurg, Milwaukee, WI 53226 USA
[4] Med Coll Wisconsin, Dept Radiol, Milwaukee, WI 53226 USA
关键词
dexamethasone; angiogenesis; brain tumor; and DSC-MRI;
D O I
10.1177/153303460500400303
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
The purpose of this study is to demonstrate the utility of dynamic susceptibility contrast (DSC) MRI-derived perfusion parameters to characterize the hemodynamic effects of dexamethasone in a 9L gliosarcoma tumor model. Twenty-four rats underwent intracerebral inoculation with 9L tumor cells. Fifteen were treated with a total of 3mg/kg of dexamethasone on days 10-14 post-inoculation, while the remaining 9 rats served as controls. Fourteen days post-inoculation, MRI images, sensitive to total and micro-vascular cerebral blood flow (CBF), mean transit time (MTT), and intravoxel transit time distributions (TTD)s were obtained using a simultaneous gradient-echo(GE)/spin-echo(SE) DSC-MRI method. Dexamethasone-treated animals had a microvascular (SE) tumor CBF that was 45.9% higher (p = 0.0008) and a MTT that was 47.8% lower (p = 0.0005) than untreated animals. With treatment, there was a non-significant 91.3% increase in total (GE) vascular CBF (P = 0.35), and a significant decrease in MTT (49.1%, p = 0.02). The total vascular and microvascular TTDs from the treated tumors were similar to normal brain, unlike the TTDs in the untreated tumors. These findings demonstrate that DSC-MRI perfusion methods can be used to non-invasively detect the morphological and functional changes in tumor vasculature that occur in response to dexamethasone treatment.
引用
收藏
页码:245 / 249
页数:5
相关论文
共 50 条
  • [21] Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities
    Knutsson, Linda
    Stahlberg, Freddy
    Wirestam, Ronnie
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2010, 23 (01) : 1 - 21
  • [22] Absolute quantification of perfusion using dynamic susceptibility contrast MRI: pitfalls and possibilities
    Linda Knutsson
    Freddy Ståhlberg
    Ronnie Wirestam
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2010, 23 : 1 - 21
  • [23] Repeatability of Cerebral Perfusion Using Dynamic Susceptibility Contrast MRI in Glioblastoma Patients
    Jafari-Khouzani, Kourosh
    Emblem, Kyrre E.
    Kalpathy-Cramer, Jayashree
    Bjornerud, Atle
    Vangel, Mark G.
    Gerstner, Elizabeth R.
    Schmainda, Kathleen M.
    Paynabar, Kamran
    Wu, Ona
    Wen, Patrick Y.
    Batchelor, Tracy
    Rosen, Bruce
    Stufflebeam, Steven M.
    TRANSLATIONAL ONCOLOGY, 2015, 8 (03): : 137 - 146
  • [24] Improved reliability of perfusion estimation in dynamic susceptibility contrast MRI by using the arterial input function from dynamic contrast enhanced MRI
    Tseng, Chih-Hsien
    Jaspers, Jaap
    Romero, Alejandra Mendez
    Wielopolski, Piotr
    Smits, Marion
    van Osch, Matthias J. P.
    Vos, Frans
    NMR IN BIOMEDICINE, 2024, 37 (01)
  • [25] Principles of T2*- Weighted Dynamic Susceptibility Contrast MRI Technique in Brain Tumor Imaging
    Shiroishi, Mark S.
    Castellazzi, Gloria
    Boxerman, Jerrold L.
    D'Amore, Francesco
    Essig, Marco
    Nguyen, Thanh B.
    Provenzale, James M.
    Enterline, David S.
    Anzalone, Nicoletta
    Doerfler, Arnd
    Rovira, Alex
    Wintermark, Max
    Law, Meng
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 41 (02) : 296 - 313
  • [26] Effects of bolus injection duration on perfusion estimates in dynamic CT and dynamic susceptibility contrast MRI
    Arvidsson, Jonathan
    Starck, Goran
    Lagerstrand, Kerstin
    Ziegelitz, Doerthe
    Jalnefjord, Oscar
    MAGNETIC RESONANCE MATERIALS IN PHYSICS BIOLOGY AND MEDICINE, 2023, 36 (01) : 95 - 106
  • [27] Diagnostic Accuracy of Arterial Spin Labeling in Comparison With Dynamic Susceptibility Contrast-Enhanced Perfusion for Brain Tumor Surveillance at 3T MRI
    Lavrova, Anna
    Teunissen, Wouter H. T.
    Warnert, Esther A. H.
    van den Bent, Martin
    Smits, Marion
    FRONTIERS IN ONCOLOGY, 2022, 12
  • [28] Effects of bolus injection duration on perfusion estimates in dynamic CT and dynamic susceptibility contrast MRI
    Jonathan Arvidsson
    Göran Starck
    Kerstin Lagerstrand
    Doerthe Ziegelitz
    Oscar Jalnefjord
    Magnetic Resonance Materials in Physics, Biology and Medicine, 2023, 36 : 95 - 106
  • [29] Use of dynamic susceptibility-contrast MRI (DSC-MRI) to assess perfusion changes in the ipsilateral brain parenchyma from glioblastoma
    Stephan Ulmer
    Carsten Liess
    Santosh Kesari
    Nadine Otto
    Torsten Straube
    Olav Jansen
    Journal of Neuro-Oncology, 2009, 91 : 213 - 220
  • [30] Use of dynamic susceptibility-contrast MRI (DSC-MRI) to assess perfusion changes in the ipsilateral brain parenchyma from glioblastoma
    Ulmer, Stephan
    Liess, Carsten
    Kesari, Santosh
    Otto, Nadine
    Straube, Torsten
    Jansen, Olav
    JOURNAL OF NEURO-ONCOLOGY, 2009, 91 (02) : 213 - 220