Extended Distal Chevron Osteotomy and Akin Osteotomy Using Bioabsorbable Materials for Treatment of Moderate to Severe Hallux Valgus

被引:3
|
作者
Song, Jae Hwang [1 ]
Kang, Chan [2 ]
Park, Won Ho [3 ]
Lee, Gi Soo [2 ]
Lee, Jeong Kil [2 ]
Kim, Dong Hwan [2 ]
Lee, Seok Won [1 ]
机构
[1] Konyang Univ Hosp, Dept Orthoped Surg, Daejeon, South Korea
[2] Chungnam Natl Univ Hosp, Dept Orthoped Surg, Daejeon, South Korea
[3] Chungnam Natl Univ, Dept Adv Organ Mat & Text Engn Syst, Daejeon, South Korea
来源
JOURNAL OF FOOT & ANKLE SURGERY | 2021年 / 60卷 / 06期
关键词
akin osteotomy; bioabsorbable material; extended distal chevron; hallux valgus; moderate; osteotomy; severe; FOREIGN-BODY REACTION; SOFT-TISSUE RELEASE; L-LACTIC ACID; INTERNAL-FIXATION; 1ST METATARSAL; CANCELLOUS BONE; SCREWS; POLYGLYCOLIDE; SCARF; BIOCOMPATIBILITY;
D O I
10.1053/j.jfas.2021.01.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
The purpose of this study was to investigate the suitability of bioabsorbable materials for fixation of extended distal chevron osteotomy and Akin osteotomy for the treatment of moderate to severe hallux valgus. We performed a retrospective analysis of extended distal chevron osteotomy and Akin osteotomy for the treatment of moderate to severe hallux valgus (33 patients, 42 feet). Fixation of extended distal chevron osteotomy and Akin osteotomy was performed using poly-L-lactic acid pins and polylactic acid/polyglycolic acid copolymer sutures, respectively. The radiological outcomes were evaluated based on the preoperative and 3-year follow-up intermetatarsal angle, hallux valgus angle, and hallux interphalangeal angle. The clinical results were assessed according to 3-year follow-up Manchester-Oxford Foot Questionnaire scores, patient satisfaction, and postoperative complications. All radiological and clinical results were compared with those of a control group treated with metallic implants. The mean 3-year follow-up intermetatarsal angle, hallux valgus angle, and hallux interphalangeal angle were significantly corrected from the preoperative values (all p < .001). The mean 3-year follow-up Manchester-Oxford Foot Questionnaire scores score was significantly improved from the preoperative values (p < .001). Regarding patient satisfaction, 88.1% of the patients reported good to excellent results. A total of seven complications were reported. All radiological and clinical results were comparable with those of control group treated with metallic implant. Based on these results, we recommend using bioabsorbable materials as another reliable device for fixation of extended distal chevron osteotomy and Akin osteotomy even for the treatment of moderate to severe hallux valgus. Published by Elsevier Inc. on behalf of the American College of Foot and Ankle Surgeons.
引用
收藏
页码:1110 / 1116
页数:7
相关论文
共 50 条
  • [31] Comparison of Radiographic and Clinical Results After Extended Distal Chevron Osteotomy With Distal Soft Tissue Release With Moderate Versus Severe Hallux Valgus
    Song, Jae Hwang
    Kang, Chan
    Hwang, Deuk Soo
    Lee, Gi Soo
    Lee, Sang Bum
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (03) : 297 - 306
  • [32] Distal chevron osteotomy with lateral release for moderate to severe hallux valgus patients aged sixty years and over
    Jae Hyeon Seo
    Ho Seong Lee
    Young Rak Choi
    Seung Hwan Park
    International Orthopaedics, 2020, 44 : 1099 - 1105
  • [33] Distal chevron osteotomy with lateral release for moderate to severe hallux valgus patients aged sixty years and over
    Seo, Jae Hyeon
    Lee, Ho Seong
    Choi, Young Rak
    Park, Seung Hwan
    INTERNATIONAL ORTHOPAEDICS, 2020, 44 (06) : 1099 - 1105
  • [34] DISTAL CHEVRON OSTEOTOMY WITH LATERAL RELEASE FOR TREATMENT OF HALLUX-VALGUS DEFORMITY
    POCHATKO, DJ
    SCHLEHR, FJ
    MURPHEY, MD
    HAMILTON, JJ
    FOOT & ANKLE INTERNATIONAL, 1994, 15 (09) : 457 - 461
  • [35] Double First Metatarsal and Akin Osteotomy for Severe Hallux Valgus
    Al-Nammari, Shafic Said
    Christofi, Theodoros
    Clark, Callum
    FOOT & ANKLE INTERNATIONAL, 2015, 36 (10) : 1215 - 1222
  • [36] An anatomical basis for the degree of displacement of the distal chevron osteotomy in the treatment of Hallux valgus
    Badwey, TM
    Dutkowsky, JP
    Graves, SC
    Richardson, EG
    FOOT & ANKLE INTERNATIONAL, 1997, 18 (04) : 213 - 215
  • [37] Third-Generation Minimally Invasive Chevron Akin Osteotomy for Hallux Valgus
    Holme, Thomas J.
    Sivaloganathan, Sivan S.
    Patel, Beejal
    Kunasingam, Kumar
    FOOT & ANKLE INTERNATIONAL, 2020, 41 (01) : 50 - 56
  • [38] Hallux Valgus Correction Using Transarticular Lateral Release With Distal Chevron Osteotomy
    Choi, Young Rak
    Lee, Ho Seong
    Jeong, Jae Jung
    Kim, Sang Woo
    Jeon, In-Ho
    Lee, Dong Ho
    Lee, Woo Chun
    FOOT & ANKLE INTERNATIONAL, 2012, 33 (10) : 838 - 843
  • [39] Effect of Akin Osteotomy on Hallux Valgus Correction After Scarf Osteotomy With Hallux Valgus Interphalangeus
    Kaufmann, Gerhard
    Hofer, Philipp
    Braito, Matthias
    Bale, Reto
    Putzer, David
    Dammerer, Dietmar
    FOOT & ANKLE INTERNATIONAL, 2019, 40 (10) : 1182 - 1188
  • [40] Comparison of Bioabsorbable Magnesium versus Titanium Screw Fixation for Modified Distal Chevron Osteotomy in Hallux Valgus
    Acar, Baver
    Kose, Ozkan
    Turan, Adil
    Unal, Melih
    Kati, Yusuf Alper
    Guler, Ferhat
    BIOMED RESEARCH INTERNATIONAL, 2018, 2018