Research on the Electrolytically-aided Denitrification on the Four-stage Rotating Biological Contactor

被引:0
|
作者
Rodziewicz, Joanna [1 ]
Filipkowska, Urszula [1 ]
Sominka, Katarzyna [1 ]
机构
[1] Uniwersytet Warminsko Mazurski, Olsztyn, Poland
来源
ROCZNIK OCHRONA SRODOWISKA | 2010年 / 12卷
关键词
AMMONIUM-RICH LEACHATE; AEROBIC RBC BIOFILM; NITROGEN REMOVAL; SIMULTANEOUS CARBON; SINGLE REACTOR; WASTE-WATER; NEUTRALIZATION; WASTEWATERS; SYSTEM;
D O I
暂无
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
Favourable solution may be use of electric current flow phenomenon on rotating biological contactor. In some branches of industry such as: metal etching, production of fertilizers and explosives manufacturing wastewater with high concentrations of nitrates V, and low concentrations of organic compounds is produced [19]. Denitrification process of such type of wastewater requires adding an external source of electron donor, such as hydrogen gas. Its low solubility and no need for secondary removal of its excess are its advantages. Sakakibara et al [11, 12] proposed a bio-electrochemical reactor, in which the denitrifying biological membrane is immobilized on cathode. On its surface, as a result of water electrolysis, the hydrogen gas is formed which is used to reduce nitrates. The review of the literature shows there is little effective technological and technical solutions enabling the removal of nitrogen compounds in rotating biological contactors. Therefore, studies were undertaken on a combination of electrochemical processes, occurring during flow of electric current in the wastewater environment with biological processes, occurring in the rotating biological contactor. Subject of this study is research into synthetic wastewater treatment on the four-stage rotating electrobiological contactor (REBC) in two runs. Run I was made with the COD/TN ratio equal to 12, run II - with the COD/TN ratio equal to 6. In both runs were used contactor I, under conventional conditions (lack of current flow), and contactor IT which worked in conditions of current flow with density of 14 mA/m(2). In contactor II disks made of stainless steel with immobilized biological film served as a cathode, whereas an electrode made of aluminum- as an anode. Research has shown that process of removal nitrogen compounds was more effective in system with current flow, then efficiency of nitrification process was equal to 92,79% (run I) and 95,4% (run 2), and efficiency of denitrification process was equal to 58,91% (run 1) and 50,95% (run 2). More effective removal of nitrogen compounds in the denitrification process was obtained as a result of the simultaneous use as an energy source, hydrogen gas produced by electrolysis of water and organic matter contained in the treated wastewater.
引用
收藏
页码:835 / 846
页数:12
相关论文
共 50 条
  • [31] 3-STAGE CONCENTRIC LABORATORY-SCALE ROTATING BIOLOGICAL CONTACTOR FOR BOD REDUCTION
    SAWARKAR, CS
    KUTTIAPPAN, NK
    MAHAJAN, SP
    INDIAN JOURNAL OF TECHNOLOGY, 1988, 26 (06): : 301 - 306
  • [32] Organic and nitrogen removal in a two-stage rotating biological contactor treating municipal wastewater
    Hiras, DN
    Manariotis, ID
    Grigoropoulos, SG
    BIORESOURCE TECHNOLOGY, 2004, 93 (01) : 91 - 98
  • [33] Development of four-stage moving bed biofilm reactor train with a pre-denitrification configuration for the removal of thiocyanate and cyanate
    Villemur, Richard
    Juteau, Pierre
    Bougie, Veronique
    Menard, Julie
    Deziel, Eric
    BIORESOURCE TECHNOLOGY, 2015, 181 : 254 - 262
  • [34] DESIGN OF A HIGHLY-LOADED FOUR-STAGE LOW-SPEED RESEARCH COMPRESSOR
    Clemen, C.
    Schrapp, H.
    Guemmer, V.
    Muelller, R.
    Kuenzelmann, M.
    Vogeler, K.
    PROCEEDINGS OF THE ASME TURBO EXPO 2008, VOL 6, PT A, 2008, : 181 - 191
  • [35] Response of rotating biological contactor started up by heterotrophic nitrification-aerobic denitrification bacteria to various C/N ratios
    Chen, Xue
    Zhang, Qian
    Zhu, Yunan
    Zhao, Tiantao
    CHEMOSPHERE, 2022, 291
  • [36] Control of nitratation in an oxygen-limited autotrophic nitrification/denitrification rotating biological contactor through disc immersion level variation
    Courtens, Emilie N. P.
    Boon, Nico
    De Clippeleir, Haydee
    Berckmoes, Karla
    Mosquera, Mariela
    Seuntjens, Dries
    Vlaeminck, Siegfried E.
    BIORESOURCE TECHNOLOGY, 2014, 155 : 182 - 188
  • [37] Oxygen-limited autotrophic nitrification-denitrification (OLAND) in a rotating biological contactor treating high-salinity wastewater
    Windey, K
    De Bo, I
    Verstraete, W
    WATER RESEARCH, 2005, 39 (18) : 4512 - 4520
  • [38] Research on the Evaluation of Logistics Efficiency in Chinese Coastal Ports Based on the Four-Stage DEA Model
    Li, Hui
    Jiang, Linli
    Liu, Jianan
    Su, Dandan
    JOURNAL OF MARINE SCIENCE AND ENGINEERING, 2022, 10 (08)
  • [39] Fluid flow modeling of a four-stage damping adjustable shock absorber and its experimental research
    Ding, Erming
    Xie, Fangwei
    Dai, Heng
    Gao, Qingsong
    Zhang, Jin
    Feng, Yixiang
    Liu, Hongtuo
    INTERNATIONAL JOURNAL OF STRUCTURAL INTEGRITY, 2018, 9 (01) : 17 - 26
  • [40] The stage approach in scaling-up immobilized-cell reactors. The example of the rotating biological contactor
    Converti, A
    CHEMICAL AND BIOCHEMICAL ENGINEERING QUARTERLY, 1996, 10 (04) : 175 - 181