Influence of sodium deposits in steam generator tubes on remote field eddy current signals

被引:12
|
作者
Thirunavukkarasu, S. [1 ]
Rao, B. P. C. [1 ]
Vaidyanathan, S. [1 ]
Jayakumar, T. [1 ]
Raj, Baldev [1 ]
机构
[1] Indira Gandhi Ctr Atom Res, Met & Mat Grp, NDE Div, EMSI Sect, Kalpakkam 603102, Tamil Nadu, India
关键词
structural integrity; steam generators; remote field eddy current; in-service inspection; non-destructive testing; sodium deposits;
D O I
10.1016/j.ijpvp.2007.10.010
中图分类号
T [工业技术];
学科分类号
08 ;
摘要
The presence of sodium deposits in defective regions of steam generator (SG) tubes of fast-breeder reactors is expected to influence the remote field eddy current (RFEC) signals. By exposing five SG tubes having uniform wall loss grooves to a sodium environment in a specially designed test vessel, changes in the shape of RFEC signals were observed and it was possible to approximate the volume of sodium deposited in defects. An invariant signal parameter was determined for quantitative characterization of defects despite the presence of sodium in the defects. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:211 / 218
页数:8
相关论文
共 50 条
  • [11] Estimating statistical properties of eddy-current signals from steam generator tubes
    Dògandzic, A
    Xiang, P
    IEEE TRANSACTIONS ON SIGNAL PROCESSING, 2005, 53 (08) : 3342 - 3348
  • [12] Simulation of eddy current testing of steam generator tubes with wear and secondary side magnetite deposits
    Sollier, T.
    Decitre, J.-M.
    Vigneron, A.
    Demaldent, E.
    Insight: Non-Destructive Testing and Condition Monitoring, 2022, 64 (02): : 73 - 78
  • [13] Simulation of eddy current testing of steam generator tubes with wear and secondary side magnetite deposits
    Sollier, T.
    Decitre, J-M
    Vigneron, A.
    Demaldent, E.
    INSIGHT, 2022, 64 (02) : 73 - 78
  • [14] Remote field eddy current testing for steam generator inspection of fast reactor
    Kobayashi, Noriyasu
    Ueno, Souichi
    Nagai, Satoshi
    Ochiai, Makoto
    Jimbo, Noboru
    NUCLEAR ENGINEERING AND DESIGN, 2011, 241 (12) : 4643 - 4648
  • [15] Analysis of characteristics of eddy-current signals from steam generator tubes using wavelets
    Chen, GZ
    Yamaguchi, A
    APPLIED ELECTROMAGNETICS, 1996, 5 : 1 - 6
  • [16] Benchmark activities of eddy current testing for steam generator tubes
    Takagi, T
    Fukutomi, H
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (IV), 2000, 17 : 235 - 252
  • [17] Modeling of eddy current probe response for steam generator tubes
    Bakhtiari, S
    Kupperman, DS
    NUCLEAR ENGINEERING AND DESIGN, 1999, 194 (01) : 57 - 71
  • [18] New eddy current probe for NDE of steam generator tubes
    Kurokawa, M
    Miyauchi, R
    Enami, K
    Matsumoto, M
    ELECTROMAGNETIC NONDESTRUCTIVE EVALUATION (III), 1999, 15 : 57 - 64
  • [19] Development of a High-Sensitive Dual Frequency Remote Field Eddy Current Instrument for Inspection of Ferromagnetic Steam Generator Tubes
    Thirunavukkarasu, S.
    Arjun, V.
    Rao, B. Purna Chandra
    Mukhopadhyay, C. K.
    IETE TECHNICAL REVIEW, 2019, 36 (02) : 203 - 208
  • [20] Discrimination method of through-wall cracks in steam generator tubes using eddy current signals
    Hur, DH
    Lee, DH
    Choi, MS
    Lee, UC
    Kim, SJ
    Han, JH
    NDT & E INTERNATIONAL, 2006, 39 (05) : 361 - 366