Design of two-dimensional ultrasonic phased array transducers

被引:11
|
作者
Mondal, SC [1 ]
Wilcox, PD [1 ]
Drinkwater, BW [1 ]
机构
[1] Univ Bristol, Dept Mech Engn, Bristol BS8 1TR, Avon, England
关键词
ultrasonic; 2D phased array; volumetric imaging;
D O I
10.1115/1.1991873
中图分类号
TH [机械、仪表工业];
学科分类号
0802 ;
摘要
Two-dimensional (2D) phased arrays have the potential to significantly change the way in which engineering components in safety critical industries are inspected. In addition to enabling a three-dimensional (3D) volume of a component to be inspected from a single location, they could also be used in a C-scan configuration. The latter would enable any point in a component to be interrogated over a range of solid angles, allowing more accurate defect characterization and sizing. This paper describes the simulation and evaluation of grid, cross and circular 2D phased array element configurations. The aim of the cross and circle configurations is to increase the effective aperture for a given number of elements. Due to the multitude of possible array element configurations a model, based on Huygens' principle, has been developed to allow analysis and comparison of candidate array designs. In addition to the element configuration, key issues such as element size, spacing, and frequency are discussed and quantitatively compared using the volume of the 3D point spread function (PSF) as a measurand. The results of this modeling indicate that, for a given number of elements, a circular array performs best and that the element spacing should be less than half a wavelength to avoid grating lobes. A prototype circular array has been built and initial results are presented. These show that a flat bottomed hole, half a wavelength in diameter, can be imaged. Furthermore, it is shown that the volume of the 3D reflection obtained experimentally from the end of the hole compares well with the volume of the 3D PSF predicted for the array at that point
引用
收藏
页码:336 / 344
页数:9
相关论文
共 50 条
  • [21] Two-dimensional ultrasound phased array design for tissue ablation for treatment of benign prostatic hyperplasia
    Saleh, KY
    Smith, NB
    INTERNATIONAL JOURNAL OF HYPERTHERMIA, 2004, 20 (01) : 7 - 31
  • [22] An array design of linear ultrasonic phased array transducer
    Huang Jing
    Zhou Sheyu
    Zhou Shiguan
    Lei Huaming
    ISTM/2007: 7TH INTERNATIONAL SYMPOSIUM ON TEST AND MEASUREMENT, VOLS 1-7, CONFERENCE PROCEEDINGS, 2007, : 3519 - 3522
  • [23] An evolution strategy for improving the design of phased array transducers
    Chen, Stephen
    Razzaqi, Sarah
    Lupien, Vincent
    2006 IEEE CONGRESS ON EVOLUTIONARY COMPUTATION, VOLS 1-6, 2006, : 2844 - +
  • [24] Measurement algorithm of two-dimensional wind vector using ultrasonic transducers
    Xi-Bo, D. (dingxibo2002@sina.com), 1600, Universitas Ahmad Dahlan (11):
  • [25] Modeling the Radiation of Ultrasonic Phased-Array Transducers with Gaussian Beams
    Huang, Ruiju
    Schmerr, Lester W., Jr.
    Sedov, Alexander
    IEEE TRANSACTIONS ON ULTRASONICS FERROELECTRICS AND FREQUENCY CONTROL, 2008, 55 (12) : 2692 - 2702
  • [26] Joint design of transceiver array for cross-shaped two-dimensional sparse hybrid MIMO phased array radar
    Wang B.-H.
    Liu Q.-G.
    Liu S.-Q.
    Li X.
    Cheng T.-H.
    Shen H.-O.
    Kongzhi yu Juece/Control and Decision, 2021, 35 (12): : 2875 - 2882
  • [27] Analysis of Electrical Impedance Matching Effect of Phased Array Ultrasonic Transducers
    Jang, Jaewon
    Lee, Hyosung
    Kim, Geonwoo
    Kim, Ki-Bok
    JOURNAL OF THE KOREAN SOCIETY FOR NONDESTRUCTIVE TESTING, 2023, 43 (05) : 357 - 366
  • [28] Simulation of Acoustic Fields of Ultrasonic Sector Phased-Array Transducers
    Muravieva O.V.
    Myshkin A.V.
    Biomedical Engineering, 2012, 46 (04) : 158 - 163
  • [29] Optimization Analysis of Acoustic Field Parameters in Phased Array Ultrasonic Transducers
    Shang, Fei
    Chen, Huilin
    Sun, Bo
    JOURNAL OF FAILURE ANALYSIS AND PREVENTION, 2024, 24 (04) : 1576 - 1587
  • [30] Two-dimensional optical phased array antenna on silicon-on-insulator
    Van Acoleyen, Karel
    Rogier, Hendrik
    Baets, Roel
    OPTICS EXPRESS, 2010, 18 (13): : 13655 - 13660