Reducing tumor growth and angiogenesis using a triple therapy measured with Contrast-enhanced ultrasound (CEUS)

被引:6
|
作者
Paprottka, Philipp Marius [1 ]
Rosspunt, Svenja [2 ]
Ingrisch, Michael [1 ]
Cyran, Clemens C. [1 ]
Nikolaou, Konstantin [1 ]
Reiser, Maximilian F. [1 ]
Mack, Brigitte [2 ]
Gires, Olivier [2 ]
Clevert, Dirk A. [1 ]
Zengel, Pamela [2 ]
机构
[1] Ludwig Maximilian Univ Hosp, Inst Clin Radiol, Munich, Germany
[2] Ludwig Maximilian Univ Hosp, Inst Ear Nose & Throat Med, Munich, Germany
来源
BMC CANCER | 2015年 / 15卷
关键词
Contrast-enhanced ultrasound (CEUS); Experimental squamous cell carcinoma; VueBox; MATRIX METALLOPROTEINASES; QUANTITATIVE ASSESSMENT; PLASMINOGEN-ACTIVATOR; REPLENISHMENT MEASUREMENTS; SQUAMOUS CARCINOMA; TISSUE PERFUSION; CANCER-THERAPY; BLOOD-FLOW; INHIBITOR; MODEL;
D O I
10.1186/s12885-015-1333-7
中图分类号
R73 [肿瘤学];
学科分类号
100214 ;
摘要
Background: To evaluate the in vivo response by detecting the anti-angiogenic and invasion-inhibiting effects of a triple-combination-therapy in an experimental-small-animal-squamous-cell-carcinoma-model using the "flash-replenishment" (FR) method to assess tissue hemodynamics via contrast-enhanced-ultrasound (CEUS). Methods: Human hypopharynx-carcinoma-cells were subcutaneously injected into the left flank of 22-female-athymic-nude-rats. After seven days of subcutaneous tumor growth, FR-measurements were performed on each rat. Treatment-group and control-group were treated every day for a period of one week, with the treatment-group receiving solvents containing a triple therapy of Upamostat (R), Celecoxib (R) and Ilomastat (R) and the control-group solvents only. On day seven, follow-up measurements were performed using the same measurement protocol to assess the effects of the triple therapy. VueBox (R) was used to quantify the kinetic parameters and additional immunohistochemistry analyses were performed for comparison with and validation of the CEUS results against established methods (Proliferation/Ki-67, vascularization/CD31, apoptosis/caspase3). Results: Compared to the control-group, the treatment-group that received the triple-therapy resulted in a reduction of tumor growth by 48.6% in size. Likewise, the immunohistochemistry results showed significant decreases in tumor proliferation and vascularization in the treatment-group in comparison to the control-group of 26%(p <= 0.05) and 32.2%(p <= 0.05) respectively. Correspondingly, between the baseline and follow-up measurements, the therapy-group was associated with a significant(p <= 0.01) decrease in the relative-Blood-Volume(rBV) in both the whole tumor(wt) and hypervascular tumor(ht) areas (p <= 0.01), while the control-group was associated with a significant (p <= 0.01) increase of the rBV in the wt area and a non-significant increase (p <= 0.16) in the ht area. The mean-transit-time (mTT) of the wt and the ht areas showed a significant increase (p <= 0.01) in the follow-up measurements in the therapy group. Conclusion: The triple-therapy is feasible and effective in reducing both tumor growth and vascularization. In particular, compared with the placebo-group, the triple-therapy-group resulted in a reduction in tumor growth of 48.6% in size when assessed by CEUS and a significant reduction in the number of vessels in the tumor of 32% as assessed by immunohistochemistry. As the immunohistochemistry supports the CEUS findings, CEUS using the "flash replenishment"(FR) method appears to provide a useful assessment of the anti-angiogenic and invasion-inhibiting effects of a triple combination therapy.
引用
收藏
页数:11
相关论文
共 50 条
  • [21] Contrast-enhanced Ultrasound Imaging of Antiangiogenic Tumor Therapy
    Klotz, Laura V.
    Clevert, Dirk-Andre
    Scheckinger, Siiri
    Strieth, Sebastian
    Eichhorn, Martin E.
    ANTICANCER RESEARCH, 2015, 35 (05) : 2571 - 2576
  • [22] Contrast-enhanced ultrasound (CEUS) in HCC diagnosis and assessment of tumor response to locoregional therapies
    Eisenbrey, John R.
    Gabriel, Helena
    Savsani, Esika
    Lyshchik, Andrej
    ABDOMINAL RADIOLOGY, 2021, 46 (08) : 3579 - 3595
  • [23] Contrast-enhanced ultrasound (CEUS) in HCC diagnosis and assessment of tumor response to locoregional therapies
    John R. Eisenbrey
    Helena Gabriel
    Esika Savsani
    Andrej Lyshchik
    Abdominal Radiology, 2021, 46 : 3579 - 3595
  • [24] Contrast-enhanced ultrasound (CEUS) of benign and malignant renal tumors: Distinguishing CEUS features differ with tumor size
    Zhu, Jianing
    Li, Nan
    Zhao, Ping
    Wang, Yanjie
    Song, Qing
    Song, Luda
    Li, Qiuyang
    Luo, Yukun
    CANCER MEDICINE, 2023, 12 (03): : 2551 - 2559
  • [25] Perfusion analysis in parotid gland tumors using contrast-enhanced ultrasound (CEUS)
    Albers, Maria Agnes
    Kuetermeyer, Julian
    Welkoborsky, Hans-Juegen
    HNO, 2022, 70 (01) : 51 - 59
  • [26] Contrast-enhanced ultrasound (CEUS) in pediatric blunt abdominal trauma
    Trinci, Margherita
    Piccolo, Claudia Lucia
    Ferrari, Riccardo
    Galluzzo, Michele
    Ianniello, Stefania
    Miele, Vittorio
    JOURNAL OF ULTRASOUND, 2019, 22 (01) : 27 - 40
  • [27] Pitfalls of contrast-enhanced ultrasound (CEUS) in the diagnosis of splenic sarcoidosis
    Tana C.
    Iannetti G.
    D'Alessandro P.
    Tana M.
    Mezzetti A.
    Schiavone C.
    Journal of Ultrasound, 2013, 16 (2) : 75 - 80
  • [28] Contrast-enhanced ultrasound (CEUS) in pediatric blunt abdominal trauma
    Margherita Trinci
    Claudia Lucia Piccolo
    Riccardo Ferrari
    Michele Galluzzo
    Stefania Ianniello
    Vittorio Miele
    Journal of Ultrasound, 2019, 22 : 27 - 40
  • [29] CONTRAST-ENHANCED ULTRASOUND (CEUS) IN THE EVALUATION OF HEMOPERITONEUM IN PATIENTS WITH CIRRHOSIS
    Abushamat, Farid
    Dietrich, Christoph F.
    Clevert, Dirk-Andre
    Piscaglia, Fabio
    Fetzer, David
    Meloni, Maria Franca
    Shiehmorteza, Masoud
    Kono, Yuko
    GASTROENTEROLOGY, 2020, 158 (06) : S1476 - S1477
  • [30] Contrast-enhanced ultrasound (CEUS): applications from the kidneys to the bladder
    Srivastava, Saubhagya
    Dhyani, Manish
    Dighe, Manjiri
    ABDOMINAL RADIOLOGY, 2024, 49 (11) : 4092 - 4112