Uncertainty analysis of measurements of the size of nanoparticles in aqueous solutions using dynamic light scattering

被引:13
|
作者
Kwon, Su Yong [1 ]
Kim, Yong-Gyoo [1 ]
Lee, Sang Hyun [1 ]
Moon, Jun Hyuk [2 ]
机构
[1] Korea Res Inst Stand & Sci, Div Phys Metrol, Taejon, South Korea
[2] Samsung Adv Inst Technol, Yongin, Gyeonggi Do, South Korea
关键词
MICROSCOPY;
D O I
10.1088/0026-1394/48/5/024
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
One of the standard methods used to measure the size of nanoparticles in aqueous solutions in situ is dynamic light scattering (DLS). The principle of this technique used to measure the real size of nanoparticles in a solution is the use of a procedure that extrapolates the apparent diffusion coefficients at different scattering angles and the sample concentration to infinite conditions. The uncertainty in the measurement is related to the extrapolating procedure used, and we have evaluated this for nanoparticles with diameters in the range 20 nm to 100 nm using the methods described in the ISO Guide to the Expression of Uncertainty in Measurement. The size of nanoparticles measured using DLS was compared with that obtained using a microscopic method, a cryo-transmission electron microscope, to check the reliability of the results obtained from the DLS measurements, which showed good agreement within the uncertainty levels evaluated.
引用
收藏
页码:417 / 425
页数:9
相关论文
共 50 条
  • [31] Micellization of alpha-olefin sulfonate in aqueous solutions studied by turbidity, dynamic light scattering and viscosity measurements
    Abed, MA
    Saxena, A
    Bohidar, HB
    COLLOIDS AND SURFACES A-PHYSICOCHEMICAL AND ENGINEERING ASPECTS, 2004, 233 (1-3) : 181 - 187
  • [32] Dynamic light scattering of dilute PVA-borax aqueous solutions
    C. Y. Chen
    J. Y. Guo
    T. L. Yu
    S. C. Wu
    Journal of Polymer Research, 1998, 5 : 67 - 76
  • [33] Dynamic light scattering evidence of a 'fragile' character of protein aqueous solutions
    Placidi, M
    Cannistraro, S
    CHEMICAL PHYSICS LETTERS, 1999, 310 (1-2) : 130 - 136
  • [34] Dynamic light scattering investigation of guar/dextran mixtures in aqueous solutions
    Pinder, DN
    Nash, W
    Hemar, Y
    Singh, H
    FOOD HYDROCOLLOIDS, 2003, 17 (04) : 463 - 468
  • [35] Reliable size determination of nanoparticles using dynamic light scattering method for in vitro toxicology assessment
    Kato, Haruhisa
    Suzuki, Mie
    Fujita, Katsuhide
    Horie, Masanori
    Endoh, Shigehisa
    Yoshida, Yasukazu
    Iwahashi, Hitoshi
    Takahashi, Kayori
    Nakamura, Ayako
    Kinugasa, Shinichi
    TOXICOLOGY IN VITRO, 2009, 23 (05) : 927 - 934
  • [37] Effects of vesicle size and shape on static and dynamic light scattering measurements
    Pencer, J
    Hallett, FR
    LANGMUIR, 2003, 19 (18) : 7488 - 7497
  • [38] DYNAMIC LIGHT-SCATTERING MEASUREMENTS OF POLYSTYRENE IN SEMIDILUTE THETA SOLUTIONS
    AMIS, EJ
    HAN, CC
    MATSUSHITA, Y
    POLYMER, 1984, 25 (05) : 650 - 658
  • [39] Fluorescence Correlation Spectroscopy and Dynamic Light Scattering Measurements in Ficoll Solutions
    Boukari, Hacene
    Nossal, Ralph
    BIOPHYSICAL JOURNAL, 2011, 100 (03) : 468 - 468
  • [40] Study of mesoscopic structures in aqueous solutions using light scattering
    Subramanian, Deepa
    Anisimov, Mikhail A.
    Yudin, Igor K.
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 2010, 240