Dynamic simulation and analysis of a water chiller refrigeration system

被引:54
|
作者
Lei, Z
Zaheeruddin, M [1 ]
机构
[1] Concordia Univ, Montreal, PQ H3G 1M8, Canada
[2] Xi An Jiao Tong Univ, Coll Power & Engn, Xian 710049, Peoples R China
关键词
water chiller; thermal expansion valve; variable frequency; dynamic simulation; steady state analysis;
D O I
10.1016/j.applthermaleng.2005.01.002
中图分类号
O414.1 [热力学];
学科分类号
摘要
In this paper, a lumped-parameter dynamic model of a water chiller refrigeration system based on mass and energy balance principles is developed. First the component models for an evaporator, compressor, condenser and a thermostatic expansion valve (TEV) were derived. These models were integrated to develop an overall model of a water chiller system. A control-oriented approach to model development was taken and the effect of control inputs such as compressor operational frequency and TEV opening fraction on the output performance of the system was investigated. The transient response characteristics show that the thermal system responses are much slower than pressure and mass flow rate responses revealing a two time-scale property of the system. Steady state performance of the system is also analyzed and graphical relationships between refrigerant mass flow rate, suction vapor superheat temperature, operation frequency and thermostatic expansion valve opening fraction are presented. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:2258 / 2271
页数:14
相关论文
共 50 条
  • [21] Analysis of Screw Chiller's Refrigeration Performance under Large Temperature Difference Cooling-Water
    Chen, Gang
    Cheng, Xin
    ADVANCES IN CIVIL AND STRUCTURAL ENGINEERING III, PTS 1-4, 2014, 501-504 : 2319 - 2322
  • [22] ANALYSIS AND SIMULATION OF AN OPEN CYCLE ABSORPTION REFRIGERATION SYSTEM
    COLLIER, RK
    SOLAR ENERGY, 1979, 23 (04) : 357 - 366
  • [23] On the activation strategy of the chiller in water-loop self-contained refrigeration systems: An experimental analysis
    Bagarella, G.
    Lazzarin, R.
    Noro, M.
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2015, 57 : 94 - 102
  • [24] Dynamic analysis of solar powered absorption refrigeration system
    Wang, Shucheng
    Fu, Zhongguang
    Zhang, Tianqing
    Zhang, Gaoqiang
    Song, Xuebo
    Taiyangneng Xuebao/Acta Energiae Solaris Sinica, 2020, 41 (01): : 66 - 71
  • [25] DYNAMIC SIMULATION AND OPTIMAL MATCHING OF A SMALL-SCALE REFRIGERATION SYSTEM
    CHEN, ZJ
    LIN, WH
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 1991, 14 (06): : 329 - 335
  • [26] Seven-order Dynamic Model and Simulation of Compression Refrigeration System
    Lu Zhen
    Wu Aiguo
    Dong Na
    PROCEEDINGS OF THE 38TH CHINESE CONTROL CONFERENCE (CCC), 2019, : 1575 - 1580
  • [27] Dynamic simulation model of enhanced vapor injection refrigeration system for aircraft
    Sun H.
    Lyu Z.
    Wu C.
    Hu H.
    Huagong Xuebao/CIESC Journal, 2021, 72 (05): : 2484 - 2492
  • [28] Potential energy benefits of integrated refrigeration system with microturbine and absorption chiller
    Hwang, YH
    INTERNATIONAL JOURNAL OF REFRIGERATION-REVUE INTERNATIONALE DU FROID, 2004, 27 (08): : 816 - 829
  • [29] AN ANALYSIS OF AN EVAPORATIVE WATER CHILLER
    SUPPLE, RG
    BROUGHTON, DR
    ASHRAE JOURNAL-AMERICAN SOCIETY OF HEATING REFRIGERATING AND AIR-CONDITIONING ENGINEERS, 1992, 34 (06): : 44 - 48
  • [30] Simulation of an ammonia-water absorption chiller
    Le Lostec, Brice
    Galanis, Nicolas
    Millette, Jocelyn
    RENEWABLE ENERGY, 2013, 60 : 269 - 283