Development of a Multi-Axis X-ray CT for Metal Artifact Reduction

被引:0
|
作者
Toru, Kano [1 ]
Koseki, Michihiko [2 ]
机构
[1] Tokyo Univ Technol, Sch Media Sci, Tokyo, Japan
[2] Shinshu Univ, Fac Text Sci & Technol, Nagano, Japan
关键词
X-ray CT; metal artifact; non-destructive inspection; reconstruction; invers problem; TOMOGRAPHY;
D O I
暂无
中图分类号
TP18 [人工智能理论];
学科分类号
081104 ; 0812 ; 0835 ; 1405 ;
摘要
As an established non-destructive diagnostic/inspection technique, X-ray CT that can generate cross-sectional images of an object has been pervasive in our lives. Despite its ubiquity, technical problems related to artifacts have remained. In particular, when metallic objects such as tooth implants or conductive wire made of lead are contained the object, a strong radial noise called metal artifacts are generated from the metallic portions. So far we have proposed reconstruction algorithms to reduce metal artifacts; however, it is difficult to apply in cases where the transmitted X-ray intensities are saturated. In this paper, we propose a new CT system based on a two axes rotation mechanism to avoid saturation of X-rays. The feasibility and potency are verified by simulation experiments. As a result of applying our proposed method, it was confirmed that metal artifacts generated from electronic devices could be reduced efficiently.
引用
收藏
页码:1344 / 1349
页数:6
相关论文
共 50 条
  • [21] Multisource x-ray system for artifact reduction in dedicated breast CT
    Becker, Amy E.
    Hernandez, Andrew M.
    Schwoebel, Paul
    Boone, John M.
    14TH INTERNATIONAL WORKSHOP ON BREAST IMAGING (IWBI 2018), 2018, 10718
  • [22] Multisource X-Ray System for Artifact Reduction in Cone Beam CT
    Becker, A.
    Hernandez, A.
    Schwoebel, P.
    Boone, J.
    MEDICAL PHYSICS, 2017, 44 (06) : 3177 - 3178
  • [23] GPU-Accelerated Dynamic Wavelet Thresholding Algorithm for X-Ray CT Metal Artifact Reduction
    Peng, Chengtao
    Qiu, Bensheng
    Li, Ming
    Yang, Yang
    Zhang, Cheng
    Gong, Lun
    Zheng, Jian
    IEEE TRANSACTIONS ON RADIATION AND PLASMA MEDICAL SCIENCES, 2018, 2 (01) : 17 - 26
  • [24] X-ray CT Metal Artifact Reduction Using Wavelet Domain L0 Sparse Regularization
    Mehranian, Abolfazl
    Ay, Mohammad Reza
    Rahmim, Arman
    Zaidi, Habib
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2013, 32 (09) : 1707 - 1722
  • [25] Metal artifact reduction method based on a constrained beam-hardening estimator for polychromatic x-ray CT
    Hur, Jin
    Kim, Dongjoon
    Shin, Yeong-Gil
    Lee, Ho
    PHYSICS IN MEDICINE AND BIOLOGY, 2021, 66 (06):
  • [26] 3D Prior Image Constrained Projection Completion for X-ray CT Metal Artifact Reduction
    Mehranian, Abolfazl
    Ay, Mohammad Reza
    Rahmim, Arman
    Zaidi, Habib
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 2013, 60 (05) : 3318 - 3332
  • [27] X-ray CT metal artifact reduction using wavelets: Arm application for imaging total hip prostheses
    Zhao, SY
    Roberston, DD
    Wang, G
    Whiting, B
    Bae, KT
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2000, 19 (12) : 1238 - 1247
  • [28] Metal Artifact Reduction in X-ray CT Image Using Discriminant Analysis Method and Sin Curve Interpolation
    Inagaki, Keisuke
    Tanaka, Toshiyuki
    2017 56TH ANNUAL CONFERENCE OF THE SOCIETY OF INSTRUMENT AND CONTROL ENGINEERS OF JAPAN (SICE), 2017, : 894 - 897
  • [29] Design of a multi-axis cryogenic sample manipulator for soft X-ray and VUV spectroscopy
    Wang, D. J.
    Chiu, C. C.
    Cheng, C. M.
    11TH INTERNATIONAL CONFERENCE ON SYNCHROTRON RADIATION INSTRUMENTATION (SRI 2012), 2013, 425
  • [30] A FRAMEWORK FOR SPECTRAL ARTIFACT CORRECTIONS IN X-RAY CT
    STONESTROM, JP
    ALVAREZ, RE
    MACOVSKI, A
    IEEE TRANSACTIONS ON BIOMEDICAL ENGINEERING, 1981, 28 (02) : 128 - 141