Membrane introduction system for trace analysis of volatile organic compounds using a single photon ionization time-of-flight mass spectrometer

被引:17
|
作者
Yamamoto, Yukio [1 ]
Kanno, Nozomu [1 ]
Tonokura, Kenichi [1 ]
Yabushita, Akihiro [2 ]
Kawasaki, Masahiro [2 ]
机构
[1] Univ Tokyo, Ctr Environm Sci, Bunkyo Ku, Tokyo 1130033, Japan
[2] Kyoto Univ, Dept Mol Engn, Kyoto 6158510, Japan
基金
日本科学技术振兴机构;
关键词
Membrane introduction; Volatile organic compounds; Photoionization; Time-of-flight mass spectrometer; ELECTRON-IMPACT IONIZATION; INLET; AIR; INTERFACE; VACUUM; PERMEATION; PARAMETERS; COMPONENTS; LIGHT; WATER;
D O I
10.1016/j.ijms.2010.07.016
中图分类号
O64 [物理化学(理论化学)、化学物理学]; O56 [分子物理学、原子物理学];
学科分类号
070203 ; 070304 ; 081704 ; 1406 ;
摘要
A silicone membrane sample introduction system combined with a vacuum ultraviolet single photon ionization time-of-flight mass spectrometer (VUV-SPI-TOFMS) has been developed to detect trace volatile organic compounds in environmental air. The maximum enrichment factors of benzene. toluene, and chlorobenzene using the membrane introduction system relative to a direct introduction system were found to be 15.3, 11.0, and 12 1, respectively. The gas permeability of toluene through the silicone membrane was consistent with that of the manufacturer's reported value. The gas permeabilities of the silicone membrane used in the present study were estimated for benzene and chlor benzene by theoretical calculations using the enrichment factors. The enrichment factors of benzene, toluene, and chlorobenzene were independent of their mixing ratios at <34 ppmv. The detection limits of benzene and chlorobenzene with the membrane introduction system were improved by one order of magnitude relative to direct introduction. Detection of almost sub-ppbv level of benzene and chlorobenzene was achieved in the membrane introduction VUV-SPI-TOFMS. (C) 2010 Elsevier B V All rights reserved
引用
收藏
页码:25 / 29
页数:5
相关论文
共 50 条
  • [41] A field-deployable, chemical ionization time-of-flight mass spectrometer
    Bertram, T. H.
    Kimmel, J. R.
    Crisp, T. A.
    Ryder, O. S.
    Yatavelli, R. L. N.
    Thornton, J. A.
    Cubison, M. J.
    Gonin, M.
    Worsnop, D. R.
    ATMOSPHERIC MEASUREMENT TECHNIQUES, 2011, 4 (07) : 1471 - 1479
  • [43] ELECTROSPRAY-IONIZATION ON A REFLECTING TIME-OF-FLIGHT MASS-SPECTROMETER
    DODONOV, AF
    CHERNUSHEVICH, IV
    LAIKO, VV
    TIME-OF-FLIGHT MASS SPECTROMETRY, 1994, 549 : 108 - 123
  • [44] Design, Construction and Calibration of a Laser Ionization Time-of-Flight Mass Spectrometer
    Tabrizchi, M.
    Farrokhpour, H.
    Abyar, F.
    Azad, H.
    Mirian, M.
    ILbeigi, V.
    PHYSICAL CHEMISTRY RESEARCH, 2014, 2 (02): : 202 - 216
  • [45] Collisional damping interface for an electrospray ionization time-of-flight mass spectrometer
    Krutchinsky, AN
    Chernushevich, IV
    Spicer, VL
    Ens, W
    Standing, KG
    JOURNAL OF THE AMERICAN SOCIETY FOR MASS SPECTROMETRY, 1998, 9 (06) : 569 - 579
  • [46] Laser-induced surface ionization in a time-of-flight mass spectrometer
    Schriemer, David C.
    Li, Liang
    Review of Scientific Instruments, 1995, 66 (1 pt 1):
  • [47] A DUAL IONIZATION SOURCE WITH LASER-DESORPTION SAMPLE INTRODUCTION IN A TIME-OF-FLIGHT MASS-SPECTROMETER
    SCHRIEMER, DC
    LI, L
    INSTRUMENTATION SCIENCE & TECHNOLOGY, 1995, 23 (04) : 317 - 328
  • [48] DUAL TIME-OF-FLIGHT MASS SPECTROMETER FOR PLASMA ANALYSIS
    ALINOVSKII, NI
    INSTRUMENTS AND EXPERIMENTAL TECHNIQUES-USSR, 1969, (03): : 781 - +
  • [49] MEMBRANE INTERFACE FOR SELECTIVE INTRODUCTION OF VOLATILE COMPOUNDS DIRECTLY INTO THE IONIZATION-CHAMBER OF A MASS-SPECTROMETER
    BIER, ME
    COOKS, RG
    ANALYTICAL CHEMISTRY, 1987, 59 (04) : 597 - 601
  • [50] Simultaneous on-line vacuum single- and multi-photon ionization on an orthogonal acceleration time-of-flight mass spectrometer platform
    Heide, J.
    Ehlert, S.
    Koziorowski, T.
    Ruger, C. P.
    Walte, A.
    Zimmermann, R.
    ANALYST, 2022, 147 (16) : 3662 - 3674