In this article three different techniques for visualizing gas-liquid mass transfer are reviewed according to their applications in air-water systems. The three techniques are: Planar Laser Induced Fluorescence (PLIF with the use of fluorescent resorufin), PLIF with Inhibition (PLIF-I with the use of a ruthenium complex), and a colorimetric technique (using a redox reaction with the pink-colored dye resorufin). For comparison purpose, the three techniques were conducted in the same experimental set-up to characterize the local oxygen mass transfer from a single air bubble (with equivalent diameter -1 mm) rising in water. This paper rigorously compares these three techniques and aims to point out their advantages and limitations. The comparison was divided into two parts: the visualization and the quantification of the mass transfer. The discussion focused on the image quality, the required equipment, and the accuracy of the quantification results including the mass flux, the diffusion coefficient and the mass transfer coefficient. A guideline was provided for choosing the technique that most accurately visualizes and characterizes the local mass transfer in gas-liquid systems. (C) 2019 Elsevier Ltd. All rights reserved.
引用
收藏
页数:11
相关论文
共 50 条
  • [41] Study of gas-liquid mass transfer in packed columns
    Mamaliga, I
    Petrescu, S
    REVISTA DE CHIMIE, 2002, 53 (10): : 660 - 663
  • [42] Gas-liquid mass transfer in microbubble column reactors
    Xie, B. Q.
    Liu, W.
    Zhang, C. H.
    Chen, Y.
    Ma, W. Y.
    Zhang, J. S.
    CHEMICAL ENGINEERING AND PROCESSING-PROCESS INTENSIFICATION, 2024, 202
  • [43] Hydrodynamics and mass transfer characteristics of gas-liquid ejectors
    Balamurugan, S.
    Lad, Mayank D.
    Gaikar, Vilas G.
    Patwardhan, Ashwin W.
    CHEMICAL ENGINEERING JOURNAL, 2007, 131 (1-3) : 83 - 103
  • [44] Gas-liquid mass transfer studies in sonochemical reactors
    Kumar, A
    Gogate, PR
    Pandit, AB
    Delmas, H
    Wilhelm, AM
    INDUSTRIAL & ENGINEERING CHEMISTRY RESEARCH, 2004, 43 (08) : 1812 - 1819
  • [45] MASS-TRANSFER IN SQUARE GAS-LIQUID CONTRACTORS
    LEVEC, J
    PAVKO, S
    CHEMICAL ENGINEERING SCIENCE, 1979, 34 (09) : 1159 - 1160
  • [46] MASS-TRANSFER IN GAS-LIQUID SLURRY REACTORS
    BEENACKERS, AACM
    VANSWAAIJ, WPM
    CHEMICAL ENGINEERING SCIENCE, 1993, 48 (18) : 3109 - 3139
  • [47] INTERFACIAL TURBULENCE IN GAS-LIQUID MASS-TRANSFER
    IMAISHI, N
    SUZUKI, Y
    HOZAWA, M
    FUJINAWA, K
    KAGAKU KOGAKU RONBUNSHU, 1980, 6 (06) : 585 - 590
  • [48] MASS TRANSFER IN MECHANICALLY AGITATED GAS-LIQUID CONTACTORS
    MEHTA, VD
    SHARMA, MM
    CHEMICAL ENGINEERING SCIENCE, 1971, 26 (03) : 461 - &
  • [49] Gas-liquid mass transfer - Influence of sparger location
    Sardeing, R
    Aubin, J
    Poux, M
    Xuereb, C
    CHEMICAL ENGINEERING RESEARCH & DESIGN, 2004, 82 (A9): : 1161 - 1168
  • [50] Enhancing gas-liquid volumetric mass transfer coefficient
    Ho, Dongil
    Kim, Kwangmin
    Earmme, Taeshik
    Kim, Choongik
    JOURNAL OF INDUSTRIAL AND ENGINEERING CHEMISTRY, 2020, 87 : 1 - 17