Noise characteristics of the reduction image displayed on liquid crystal display in digital mammography

被引:0
|
作者
Yokoyama, Daigo [1 ]
Kimura, Yukiyoshi [2 ]
Imanishi, Yasuhiro [3 ]
Fujita, Naotoshi [4 ]
Kodera, Yoshie [1 ]
机构
[1] Nagoya Univ, Sch Hlth Sci, Higashi Ku, 1-1-20 Daiko Minami, Nagoya, Aichi 4618673, Japan
[2] Nagoya Univ, Grad Sch Med Sci, Higashi Ku, Nagoya, Aichi 4618673, Japan
[3] JA Mie Kouseiren Matsusaka Gen Hosp, Matsusaka 5158566, Japan
[4] Nagoya Univ Hosp, Dept Radiol Technol, Showa Ku, Nagoya, Aichi 4668560, Japan
关键词
phase contrast mammography; reduction image; reduction rate; interpolation; noise power spectrum;
D O I
10.1117/12.844093
中图分类号
O43 [光学];
学科分类号
070207 ; 0803 ;
摘要
Soft-copy diagnosis of medical images is currently widespread. Because the pixel size of a digital mammogram is very small, the matrix size is extremely large. Especially the matrix size of phase contrast mammography (PCM) is very large compared with a conventional mammography. When such an image is displayed on a liquid crystal display (LCD), it is displayed as a reduction image. Therefore, it is necessary to use an appropriate reduction rate and an interpolation method such that the reduction processing does not influence the diagnosis. We obtained a uniform image exposure and measured the noise power spectrum (NPS) of the image reduced by using the nearest neighbor, bilinear, and bicubic methods with several reduction rates. Our results showed that the best interpolation method was the bilinear method. Moreover, the NPS value increased by a factor of the square of the inverse of the reduction rate.
引用
收藏
页数:8
相关论文
共 50 条
  • [21] Reduction of speckle noise in the reconstructed image of digital holography
    Cai, Xiao-ou
    OPTIK, 2010, 121 (04): : 394 - 399
  • [22] Dual-energy digital mammography for calcification imaging: noise reduction techniques
    Kappadath, S. Cheenu
    Shaw, Chris C.
    PHYSICS IN MEDICINE AND BIOLOGY, 2008, 53 (19): : 5421 - 5443
  • [23] Reduction of speckle noise in digital holography by using digital image processing
    Garcia-Sucerquia, J
    Ramírez, JAH
    Prieto, DV
    OPTIK, 2005, 116 (01): : 44 - 48
  • [24] Conducted Emission Reduction Technology for Liquid Crystal Display Devices
    Kim, Byunghee
    Lee, Seungjae
    2017 IEEE INTERNATIONAL SYMPOSIUM ON ELECTROMAGNETIC COMPATIBILITY & SIGNAL/POWER INTEGRITY (EMCSI), 2017,
  • [25] Liquid crystal display with high transmittance and excellent image quality
    Liu, Jing
    Huang, Xiaoying
    Peng, Zhigang
    He, Xiaojin
    Xu, Hongyuan
    Optik, 2025, 320
  • [26] On the real-time reconstruction of digital holograms displayed on photosensitive liquid crystal systems
    Miniewicz, A.
    Mysliwiec, J.
    Kajzar, F.
    Parka, J.
    OPTICAL MATERIALS, 2006, 28 (12) : 1389 - 1397
  • [27] On the real-time reconstruction of digital holograms displayed on photosensitive liquid crystal systems
    Institute of Physical and Theoretical Chemistry, Wroclaw University of Technology, Wyb. Wyspianskiego 27, 50-370 Wroclaw, Poland
    不详
    不详
    Opt Mater, 12 (1389-1397):
  • [28] Detectability of a lung nodule displayed on a liquid-crystal display monitor with different maximum luminance settings
    Takahashi K.
    Sueoka M.
    Yoon Y.
    Hiwasa T.
    Hatanaka S.
    Nakamura Y.
    Hashimoto N.
    Ohki M.
    Morishita J.
    Radiological Physics and Technology, 2010, 3 (1) : 10 - 15
  • [29] Variations of the Chromaticity in Gray-Scale Images Displayed on Different Liquid-Crystal Display Monitors
    Akamine, H.
    Awamoto, S.
    Miyazaki, H.
    Nakamura, Y.
    Hashimoto, N.
    Morishita, J.
    MEDICAL PHYSICS, 2011, 38 (06)
  • [30] The optical characteristics of liquid crystal display with different space width
    Mai, Chen-Fu
    Lin, Tzu-Chin
    Huang, Kuei-Wei
    Liu, Chun-HSiu
    AD'07: Proceedings of Asia Display 2007, Vols 1 and 2, 2007, : 1162 - 1163