Diagnosis and stage of Graves' ophthalmopathy: Efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance imaging

被引:34
|
作者
Hu, Hao [1 ]
Xu, Xiao-Quan [1 ]
Wu, Fei-Yun [1 ]
Chen, Huan-Huan [2 ]
Su, Guo-Yi [1 ]
Shen, Jie [1 ]
Hong, Xun-Ning [1 ]
Shi, Hai-Bin [1 ]
机构
[1] Nanjing Med Univ, Affiliated Hosp 1, Dept Radiol, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
[2] Nanjing Med Univ, Affiliated Hosp 1, Dept Endocrinol, 300 Guangzhou Rd, Nanjing 210029, Jiangsu, Peoples R China
关键词
Graves' ophthalmopathy; lacrimal gland; magnetic resonance imaging; diagnosis; stage; THYROID EYE DISEASE; COMPUTED-TOMOGRAPHY; CLINICAL ACTIVITY; TSH RECEPTOR; ORBITOPATHY; DIMENSIONS; MANAGEMENT;
D O I
10.3892/etm.2016.3389
中图分类号
R-3 [医学研究方法]; R3 [基础医学];
学科分类号
1001 ;
摘要
The aim of the present study was to determine the efficacy of quantitative measurements of the lacrimal gland based on 3-T magnetic resonance (MR) imaging in the diagnosis and staging of Graves' ophthalmopathy (GO). The study retrospectively enrolled 33 patients with GO (the GO group) and 24 healthy volunteers [the healthy control (HC) group] with orbit MR imaging performed using a 3-T MR scanner. Quantitative parameters of the lacrimal gland, including axial length, axial width, axial area, coronal length, coronal width, coronal area, volume and signal intensity ratio (SIR) of the lacrimal gland to the ipsilateral temporal muscle were measured. The difference of quantitative parameters between the GO and HC groups, or between active and inactive GO groups were evaluated using a Student's t-test. Receiver operating characteristic analyses were used to evaluate the diagnostic value of the significant parameters in discriminating patients with GO from healthy controls, or discriminating active from inactive GO. All the quantitative measurements of the GO patients were significantly larger than those of the healthy controls (P < 0.05), with the exception of the coronal length (P = 0.150). Axial and coronal width had the best efficacy in discriminating patients with GO from healthy controls. Only SIR was found to be different between the active and inactive GO groups (P = 0.001). Setting a SIR of 2.57 as the threshold value, the optimal efficacy was achieved (area under the curve, 0.711; sensitivity, 57.7%; specificity, 77.5%) in discriminating between active and inactive GO. Quantitative measurements of the lacrimal gland based on 3-T MR imaging may assist in the diagnosis and stage of GO.
引用
收藏
页码:725 / 729
页数:5
相关论文
共 50 条
  • [21] 3-T breast magnetic resonance imaging in patients with suspicious microcalcifications on mammography
    B. L. Stehouwer
    L. G. Merckel
    H. M. Verkooijen
    N. H. G. M. Peters
    R. M. Mann
    K. M. Duvivier
    W. P. Th. M. Mali
    P. H. M. Peeters
    W. B. Veldhuis
    M. A. A. J. van den Bosch
    European Radiology, 2014, 24 : 603 - 609
  • [22] Intraoperative magnetic resonance imaging-guided neurosurgery at 3-T - Comments
    Nimsky, C
    Fahlbusch, R
    Lunsford, LD
    Tronnier, VM
    NEUROSURGERY, 2006, 58 (04) : 345 - 346
  • [23] The Anatomical and Electrophysiological Subthalamic Nucleus Visualized by 3-T Magnetic Resonance Imaging COMMENTS
    Pilitsis, Julie G.
    Hebb, Adam O.
    NEUROSURGERY, 2012, 71 (06) : 1095 - 1095
  • [24] Magnetic resonance imaging of the craniocervical junction at 3-T: Observation of the accessory atlantoaxial ligaments
    Yuksel, Murvet
    Heiserman, Joseph E.
    Sonntag, Volker K. H.
    NEUROSURGERY, 2006, 59 (04) : 888 - 892
  • [25] Minimum detectable change in water diffusion using 3-T magnetic resonance imaging
    Lau, Raymond W. -M.
    Goodyear, Bradley G.
    NEUROIMAGE, 2007, 36 (03) : 491 - 496
  • [26] Anatomy of the distal biceps tendon: an in vivo 3-T magnetic resonance imaging study
    Boyle, Alexander Buckenham
    Ke, James Uri
    Ragg, Amanda
    MacLean, Simon B. M.
    JOURNAL OF SHOULDER AND ELBOW SURGERY, 2022, 31 (06) : 1316 - 1322
  • [27] The combination of T2-mapping value of lacrimal gland and clinical indicators can improve the stage prediction of Graves' ophthalmopathy compared to clinical activity scores
    Jiang, Mengda
    Song, Xuefei
    Zhang, Haiyang
    Tao, Xiaofeng
    Yang, Gongxin
    Wang, Yishi
    Liu, Yuting
    Zhou, Huifang
    Sun, Jing
    Li, Yinwei
    ENDOCRINE, 2022, 78 (02) : 321 - 328
  • [28] The combination of T2-mapping value of lacrimal gland and clinical indicators can improve the stage prediction of Graves’ ophthalmopathy compared to clinical activity scores
    Mengda Jiang
    Xuefei Song
    Haiyang Zhang
    Xiaofeng Tao
    Gongxin Yang
    Yishi Wang
    Yuting Liu
    Huifang Zhou
    Jing Sun
    Yinwei Li
    Endocrine, 2022, 78 : 321 - 328
  • [29] Successful serial imaging of the mouse cerebral arteries using conventional 3-T magnetic resonance imaging
    Makino, Hiroshi
    Hokamura, Kazuya
    Natsume, Takahiro
    Kimura, Tetsuro
    Kamio, Yoshinobu
    Magata, Yasuhiro
    Namba, Hiroki
    Katoh, Takasumi
    Sato, Shigehito
    Hashimoto, Tomoki
    Umemura, Kazuo
    JOURNAL OF CEREBRAL BLOOD FLOW AND METABOLISM, 2015, 35 (09): : 1523 - 1527
  • [30] Comparison of arterial and venous coronary artery bypass flow measurements using 3-T magnetic resonance phase contrast imaging
    Reineke, David
    Ith, Michael
    Goeber, Volkhard
    Rosskopf, Andrea Bianca
    Hess, Otto
    Carrel, Thierry
    Czerny, Martin
    Hoppe, Hanno
    EUROPEAN JOURNAL OF RADIOLOGY, 2012, 81 (04) : E502 - E506