The effect of false lumen procedures during thoracic endovascular aortic repair in patients with chronic DeBakey type IIIB dissections

被引:21
|
作者
Kim, Tae-Hoon [1 ]
Song, Suk-Won [1 ]
Lee, Kwang-Hun [2 ]
Baek, Min-Young [1 ]
Yoo, Kyung-Jong [3 ]
Cho, Bum-Koo [4 ,5 ]
机构
[1] Gangnam Severance Hosp, Dept Cardiovasc Surg, Seoul, South Korea
[2] Gangnam Severance Hosp, Dept Intervent Radiol, Seoul, South Korea
[3] Severance Hosp, Yonsei Cardiovasc Hosp, Dept Cardiovasc Surg, Seoul, South Korea
[4] Yonsei Univ, Coll Med, Seoul, South Korea
[5] Korea Heart Fdn, Seoul, South Korea
关键词
Chronic DeBakey IIIB; Dissection; False lumen procedure; TEVAR; COVERED STENT DEVICES; EMBOLIZATION; OUTCOMES; DISEASE;
D O I
10.1016/j.jvs.2018.01.045
中图分类号
R61 [外科手术学];
学科分类号
摘要
Objective: Although thoracic endovascular aortic repair (TEVAR) is commonly used for chronic DeBakey type IIIB (CDIIIB) dissections, aortic remodeling outcomes after the procedure have been unsatisfactory. Persistent retrograde flow to the false lumen (FL) through re-entry tears commonly causes treatment failure. The aim of this study was to clarify the safety and effect of the FL procedure (FLP) for aortic remodeling in patients with CDIIIB dissections. Methods: From 2012 to 2016, there were 73 patients who underwent TEVAR for CDIIIB dissections. The surgery, accompanied by the FLP, was performed in 41 patients (group A, 56%); 32 patients (group B, 44%) underwent TEVAR alone. The FLP was defined as blocking the retrograde FL flow with commercial materials. Outcomes included whole thoracic aorta FL thrombosis and diameter change in the true lumen and FL. Diameters were measured at three levels (left subclavian artery, pulmonary artery bifurcation, and celiac axis). Results: No in-hospital mortality was observed. There was one case each of paraplegia and stroke postoperatively. The whole thoracic aorta FL thrombosis rate was significantly higher in group A (83% vs 56%; P = .002). Significant aortic remodeling (true lumen expansion and FL regression) was observed in both groups. In multivariable Cox regression analysis, the FLP and the number of re-entries were independent predictors for thoracic FL thrombosis (hazard ratio, 2.339 [P = .009] and 0.709 [P < .001], respectively). Conclusions: Full-coverage TEVAR with the FLP seems to be a safe endovascular treatment and promotes thoracic FL thrombosis for patients with CDIIIB dissections.
引用
收藏
页码:976 / 984
页数:9
相关论文
共 50 条
  • [41] Thoracic Endovascular Aortic Repair After Iatrogenic Aortic Dissection and False Lumen Stent Grafting
    Schrimpf, Claudia
    Teebken, Omke E.
    Wilhelmi, Mathias
    ANNALS OF THORACIC SURGERY, 2015, 99 (04): : 1447 - 1449
  • [42] Factors affecting distal false lumen enlargement after thoracic endovascular aortic repair for type B aortic dissection
    Tang, Qian-hui
    Chen, Jing
    Long, Zhen
    Wang, Yu-Lin
    Su, Xuan-an
    Qiu, Jian-ye
    Lin, Qiu-ning
    Zhang, Jiang-feng
    Qin, Xiao
    HELIYON, 2023, 9 (06)
  • [43] Impact of Endovascular False Lumen Embolization on Thoracic Aortic Remodeling in Chronic Dissection
    Miletic, Kyle G.
    Kindzelski, Bogdan A.
    Hodges, Kevin E.
    Beach, Jocelyn
    Tong, Michael Z.
    Bakaeen, Faisal
    Johnston, Douglas R.
    Desai, Milind
    Lyden, Sean
    Roselli, Eric E.
    ANNALS OF THORACIC SURGERY, 2021, 111 (02): : 495 - 501
  • [44] Racial Disparity in Patients Undergoing Thoracic Endovascular Aortic Repair for Thoracic Aortic Aneurysms and Dissections
    Serna-Gallegos, Derek R.
    Aranda-Michel, Edgar
    Brown, James
    Yousef, Sarah
    Wang, Yisi
    Navid, Forozan
    CIRCULATION, 2021, 144
  • [45] Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography
    Mohamed Eissa
    Asadollah Mir-Ghassemi
    Sudhir Nagpal
    Hesham F. Talab
    JA Clinical Reports, 8
  • [46] Detection of inadvertent passage of guide wire into the false lumen during thoracic endovascular aortic repair of Type B aortic dissection by transesophageal echocardiography
    Eissa, Mohamed
    Mir-Ghassemi, Asadollah
    Nagpal, Sudhir
    Talab, Hesham F.
    JA CLINICAL REPORTS, 2022, 8 (01)
  • [47] Volumetric analysis of type B aortic dissections treated with thoracic endovascular aortic repair
    Stanley, Gregory A.
    Murphy, Erin H.
    Knowles, Martyn
    Ilves, Mihaila
    Jessen, Michael E.
    Dimaio, J. Michael
    Modrall, J. Gregory
    Arko, Frank R., III
    JOURNAL OF VASCULAR SURGERY, 2011, 54 (04) : 985 - 992
  • [48] A misplaced guide wire in the false lumen during endovascular repair of a type B aortic dissection
    Fayad, Ashraf
    CANADIAN JOURNAL OF ANAESTHESIA-JOURNAL CANADIEN D ANESTHESIE, 2007, 54 (11): : 947 - 948
  • [49] A misplaced guide wire in the false lumen during endovascular repair of a type B aortic dissection
    Ashraf Fayad
    Canadian Journal of Anesthesia, 2007, 54 : 947 - 948
  • [50] The Level of Persistent False Lumen Perfusion Is Associated With Increased Aortic Size After Thoracic Endovascular Aortic Repair in Patients With Type B Aortic Dissection
    Kabbani, Loay
    Nadig, Jeffrey
    Ranjal, Rohit Shenoy
    Rteil, Ali
    Linchangco, Richard
    Weaver, Mitchell
    Nypaver, Timothy
    Shepard, Alexander
    JOURNAL OF VASCULAR SURGERY, 2019, 70 (03) : E77 - E78