Photothermal enhancement in sensitivity of lateral flow assays for detection of E-coli O157:H7

被引:38
|
作者
Shirshahi, Vahid [1 ,4 ]
Tabatabaei, Seyed Nasrollah [1 ]
Hatamie, Shadie [3 ]
Saber, Reza [1 ,2 ]
机构
[1] Univ Tehran Med Sci, Sch Adv Technol Med, Dept Med Nanotechnol, Tehran, Iran
[2] Univ Tehran Med Sci, Res Ctr Sci & Technol Med, Tehran, Iran
[3] Stem Cell Technol Res Ctr, Tehran, Iran
[4] Shahroud Univ Med Sci, Sch Med, Shahroud, Iran
关键词
Sensitivity improvement; Signal amplification; Photothermal quantification; Lateral flow assay; Reduced graphene oxide; REDUCED GRAPHENE OXIDE; PAPER SENSOR; DEVICE;
D O I
10.1016/j.colsurfb.2019.110721
中图分类号
Q6 [生物物理学];
学科分类号
071011 ;
摘要
Lateral flow immunoassay (LFA) is a well-known point-of-care technology for the detection of various analytes. However, low sensitivity and lack of quantitative results are some of its critical drawbacks. Here we report a photothermal enhanced lateral flow sensor on the basis of the photothermal properties of reduced graphene oxide (rGO) for the detection of E-coli O157:H7 as a model pathogen. The calibration curve of the photothermal method exhibited a linear range from 5 x 10(5) to 5 x 10(7) CFU/ml with a correlation coefficient of R-2 = 0.96 and a regression equation of y = 8.1x-43 for standard bacteria solutions in phosphate buffer. The limit of detection was similar to 5 x 10(5) CFU/ml for standard bacteria solutions, which was a 10-fold enhancement in sensitivity compared to the qualitative results. Specificity experiments showed that the photothermal method can only detect the target bacteria among 6 types of bacteria strains. It was confirmed that the developed technique could be a highly potential method for the rapid detection field because it can provide fast quantitative results with improved sensitivity.
引用
收藏
页数:6
相关论文
共 50 条
  • [22] The biocontrol of E-coli O157:H7 at farm level
    McGee, P
    Sheridan, JJ
    Earley, B
    Leonard, N
    FOOD SAFETY ASSURANCE IN THE PRE-HARVEST PHASE, VOL 1: FOOD SAFETY ASSURANCE AND VETERINARY PUBLIC HEALTH, 2002, : 309 - 310
  • [23] An overview of methods for identification of E-coli O157:H7
    Tortorello, ML
    ABSTRACTS OF PAPERS OF THE AMERICAN CHEMICAL SOCIETY, 1997, 214 : 16 - AGFD
  • [24] Lateral flow assay strip for detection of Escherichia coli O157:H7
    Suria, M. S.
    Afendy, Mohd A. T.
    Azlina, Noor M.
    Zamri, I
    INTERNATIONAL FOOD RESEARCH JOURNAL, 2015, 22 (06): : 2587 - 2593
  • [25] An anti E-coli O157:H7 antibody-immobilized microcantilever for the detection of Escherichia coli (E-coli)
    Zhang, J
    Ji, HF
    ANALYTICAL SCIENCES, 2004, 20 (04) : 585 - 587
  • [26] Flow-through immunofiltration assay system for rapid detection of E-coli O157:H7
    Abdel-Hamid, I
    Ivnitski, D
    Atanasov, P
    Wilkins, E
    BIOSENSORS & BIOELECTRONICS, 1999, 14 (03): : 309 - 316
  • [27] A remarkable sensitivity enhancement in a gold nanoparticle-based lateral flow immunoassay for the detection of Escherichia coli O157:H7
    State Key Laboratory of Food Science and Technology, Nanchang University, Nanchang
    330047, China
    不详
    315201, China
    RSC Adv., 56 (45092-45097):
  • [28] A remarkable sensitivity enhancement in a gold nanoparticle-based lateral flow immunoassay for the detection of Escherichia coli O157:H7
    Cui, Xi
    Huang, Youju
    Wang, Jingyun
    Zhang, Lei
    Rong, Yun
    Lai, Weihua
    Chen, Tao
    RSC ADVANCES, 2015, 5 (56) : 45092 - 45097
  • [29] A high density microelectrode array biosensor for detection of E-coli O157:H7
    Radke, SA
    Alocilja, EC
    BIOSENSORS & BIOELECTRONICS, 2005, 20 (08): : 1662 - 1667
  • [30] A net fishing enrichment strategy for colorimetric detection of E-coli O157:H7
    Ren, Wen
    Liu, Wenjie
    Irudayaraj, Joseph
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 247 : 923 - 929