Engineering of CuO/ZrO2 nanocomposite-based electrochemical sensor for the selective detection of hydrogen peroxide

被引:11
|
作者
Manjushree, S. G. [1 ]
Adarakatti, Prashanth S. [2 ]
Udayakumar, Velu [1 ,2 ,3 ]
机构
[1] Siddaganga Inst Technol, Dept Chem, Tumkur 572102, India
[2] SVM Arts Sci & Commerce Coll, Dept Chem, Ilkal 587125, India
[3] MVJ Coll Engn, Dept Chem, Bangalore 560067, Karnataka, India
关键词
Electrochemical sensor; Copper oxide; Zirconia; H2O2; Cyclic voltammetry; Amperometry; GRAPHITE COMPOSITE ELECTRODES; COPPER-OXIDE NANOSTRUCTURES; NANOPARTICLES; PERFORMANCE; CATALYSTS; ZIRCONIA; FILM; CU;
D O I
10.1007/s11581-021-04243-2
中图分类号
O64 [物理化学(理论化学)、化学物理学];
学科分类号
070304 ; 081704 ;
摘要
For the first time, non-enzymatic hydrogen peroxide (H2O2) electrochemical sensor based on copper oxide/zirconia nanocomposite (CuO/ZrO2 nanocomposite) has been designed and constructed. In the present study, simple hydrothermal methods were used to synthesize the materials followed by calcination process. The structural and morphological properties of the prepared nanocomposites were investigated by using various analytical and spectroscopic techniques, namely, TEM, FE-SEM-EDAX, XPS, XRD, and BET surface area. In addition, the electrochemical properties were explored by using electrochemical tool such as cyclic voltammetry and amperometric techniques. The obtained results clearly demonstrated that the prepared material hold excellent-crystallinity, well-defined honeycomb-like framework and exhibited an improved analytical performance in the form of current towards the detection of H2O2 due to the presence of ZrO2 which could prevent the agglomeration of duel oxidation state of copper oxide nanoparticles and improved the electrocatalytic performance of copper oxide. Furthermore, the ZrO2's ionic electrical conductivity can aid faster electron transfer at the modified electrode. The proposed electrochemical sensor exhibited a wide working linear range of 50-800 mu M, good sensitivity of 0.28 mu A mu M-1 cm(-2), and lower detection limit 14.5 mu M (S/N = 3). Also in the presence of biologically co-interfering compounds such as glucose, dopamine, ascorbic acid, and uric acid, the proposed sensor had an exceptional selectivity.
引用
收藏
页码:5309 / 5322
页数:14
相关论文
共 50 条
  • [31] A cortisol nanocomposite-based electrochemical sensor for enantioselective recognition of mandelic acid
    Borazjani, Marjan
    Mehdinia, Ali
    Jabbari, Ali
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2018, 22 (02) : 355 - 363
  • [32] A cortisol nanocomposite-based electrochemical sensor for enantioselective recognition of mandelic acid
    Marjan Borazjani
    Ali Mehdinia
    Ali Jabbari
    Journal of Solid State Electrochemistry, 2018, 22 : 355 - 363
  • [33] BiVO4/TiO2 nanocomposite: Electrochemical sensor for hydrogen peroxide
    Derbali, Maram
    Othmani, Abdelhak
    Kouass, Salah
    Touati, Fathi
    Dhaouadi, Hassouna
    MATERIALS RESEARCH BULLETIN, 2020, 125
  • [34] Zeolitic imidazolate framework-8/polyaniline nanocomposite-based electrochemical sensor for sensitive detection of imidaclothiz
    He, Ziyan
    Li, Zhihui
    Feng, Tao
    Cui, Jin
    Li, Fengting
    ANALYTICAL SCIENCES, 2023, 39 (11) : 1857 - 1863
  • [35] A novel Au-NPs/DBTTA nanocomposite-based electrochemical sensor for the detection of ascorbic acid (AA)
    Mecheri, Nacira
    Lefrada, Leila
    Benounis, Messaoud
    Hassine, Chedia Ben
    Berhoumi, Houcine
    Mabrouk, Chama
    SENSOR REVIEW, 2024, 44 (06) : 712 - 720
  • [36] Zeolitic imidazolate framework-8/polyaniline nanocomposite-based electrochemical sensor for sensitive detection of imidaclothiz
    Ziyan He
    Zhihui Li
    Tao Feng
    Jin Cui
    Fengting Li
    Analytical Sciences, 2023, 39 : 1857 - 1863
  • [37] Detection of hydrogen peroxide in beer by polyoxometalates electrochemical sensor
    Zhang, Bing
    Chen, Xiaowen
    Li, Yulian
    Wang, Li
    Wei, Haocheng
    Chinese Journal of Analysis Laboratory, 2024, 43 (10) : 1411 - 1416
  • [38] A Hydrogen Peroxide Electrochemical Sensor Based on Core-Shell MnO2-SiO2-Ag Nanocomposite
    Liu, Jiangtao
    Sheng, Qinglin
    Nie, Fei
    Zheng, Jianbin
    JOURNAL OF THE ELECTROCHEMICAL SOCIETY, 2014, 161 (10) : B225 - B229
  • [39] A novel nonenzymatic hydrogen peroxide electrochemical sensor based on SnO2-reduced graphene oxide nanocomposite
    Fu, Li
    Zheng, Yuhong
    Wang, Aiwu
    Cai, Wen
    Fu, Zhuxian
    Peng, Feng
    Sensor Letters, 2015, 13 (01) : 81 - 84
  • [40] A chemiluminescence flow sensor for the selective detection of hydrogen peroxide
    Fuhrmann, B
    Janasek, D
    Spohn, U
    FIELD SCREENING EUROPE 2001, 2002, : 289 - 292