Consistent intensity correction of MR images

被引:0
|
作者
Hellier, P [1 ]
机构
[1] INRIA, IRISA, Vista Project, F-35042 Rennes, France
来源
2003 INTERNATIONAL CONFERENCE ON IMAGE PROCESSING, VOL 1, PROCEEDINGS | 2003年
关键词
D O I
暂无
中图分类号
TB8 [摄影技术];
学科分类号
0804 ;
摘要
In the last few years, there has been an increasing number of research project to study the brain. These projects nowadays involve various research centers and deal with large databases of 3D images. However, the intensity of similar anatomical tissues is often different because of the acquisition process. This is problematic since the analysis of MR images (registration, segmentation and voxel-based algorithms) may rely on the hypothesis that corresponding anatomical points have a similar luminance. In this paper, a new fully-automatic method to correct for intensity differences in MR images is presented that does not require spatial alignment. We show that the intensity correction significantly improves a non-rigid registration algorithm.
引用
收藏
页码:1109 / 1112
页数:4
相关论文
共 50 条
  • [41] Intensity Inhomogeneity Correction of Structural MR Images: A Data-Driven Approach to Define Input Algorithm Parameters
    Ganzetti, Marco
    Wenderoth, Nicole
    Mantini, Dante
    FRONTIERS IN NEUROINFORMATICS, 2016, 10
  • [42] An Interleaved Otsu Segmentation for MR Images with Intensity Inhomogeneity
    Xiong, Haoqi
    Gao, Jingjing
    Zhu, Chongjin
    Li, Yanling
    Zhang, Shu
    Xie, Mei
    IEICE TRANSACTIONS ON INFORMATION AND SYSTEMS, 2014, E97D (11): : 2974 - 2978
  • [43] PATCH BASED INTENSITY NORMALIZATION OF BRAIN MR IMAGES
    Roy, Snehashis
    Carass, Aaron
    Prince, Jerry L.
    2013 IEEE 10TH INTERNATIONAL SYMPOSIUM ON BIOMEDICAL IMAGING (ISBI), 2013, : 342 - 345
  • [44] Retrospective correction of MR intensity inhomogeneity by information minimization
    Likar, B
    Viergever, MA
    Pernus, F
    MEDICAL IMAGE COMPUTING AND COMPUTER-ASSISTED INTERVENTION - MICCAI 2000, 2000, 1935 : 375 - 384
  • [45] Retrospective correction of MR intensity inhomogeneity by information minimization
    Likar, B
    Viergever, MA
    Pernus, F
    IEEE TRANSACTIONS ON MEDICAL IMAGING, 2001, 20 (12) : 1398 - 1410
  • [46] Consistent intensity inhomogeneity correction in water-fat MRI
    Andersson, Thord
    Romu, Thobias
    Karlsson, Anette
    Noren, Bengt
    Forsgren, Mikael F.
    Smedby, Orjan
    Kechagias, Stergios
    Almer, Sven
    Lundberg, Peter
    Borga, Magnus
    Leinhard, Olof Dahlqvist
    JOURNAL OF MAGNETIC RESONANCE IMAGING, 2015, 42 (02) : 468 - 476
  • [47] Consistent Segmentation Based Color Correction for Coarsely Registered Images
    Wang, Haoxing
    Dai, Longquan
    Zhang, Xiaopeng
    2013 SECOND IAPR ASIAN CONFERENCE ON PATTERN RECOGNITION (ACPR 2013), 2013, : 319 - 324
  • [48] Correction of Artifacts in Diffusion-Weighted MR Images
    Marcon, Petr
    Bartusek, Karel
    Korinek, Radim
    Dokoupil, Zdenek
    2011 34TH INTERNATIONAL CONFERENCE ON TELECOMMUNICATIONS AND SIGNAL PROCESSING (TSP), 2011, : 391 - 397
  • [49] Automatic motion correction of clinical shoulder MR images
    Manduca, A
    McGee, KP
    Welch, EB
    Felmlee, JP
    Ehman, RL
    MEDICAL IMAGING 1999: IMAGE PROCESSING, PTS 1 AND 2, 1999, 3661 : 367 - 374
  • [50] Distortion Characterization and Correction of MR-SIM Images
    Price, R.
    Hearshen, D.
    Wen, N.
    Chetty, I.
    Glide-Hurst, C.
    MEDICAL PHYSICS, 2014, 41 (06) : 99 - 100