Compartment fire phenomena under limited ventilation

被引:115
|
作者
Utiskul, Y [1 ]
Quintiere, JG
Rangwala, AS
Ringwelski, BA
Wakatsuki, K
Naruse, T
机构
[1] Univ Maryland, Dept Fire Protect Engn, College Pk, MD 20742 USA
[2] Bldg Res Inst, Dept Fire Engn, Tsukuba, Ibaraki, Japan
关键词
compartment fires; low ventilation; limited ventilation; flame extinction;
D O I
10.1016/j.firesaf.2005.02.002
中图分类号
TU [建筑科学];
学科分类号
0813 ;
摘要
Fire behavior of heptane pool fires were investigated in a small-scale 40 cm cubic compartment with wall vents at the ceiling (top vent) and the floor (bottom vent). The measurements included pressure, mass loss, temperature, heat flux, and gas mole fraction. Flame oscillations, ghosting, and burning at the air inlet were seen. The regime of limited ventilation was examined to study the effect of extinction and the influence of oxygen. A theory based on a critical flame temperature showed that extinction depends on heating as well as oxygen concentration. A complete uniform property model was developed and its solution agrees qualitatively with the measurements. (c) 2005 Elsevier Ltd. All rights reserved.
引用
收藏
页码:367 / 390
页数:24
相关论文
共 50 条
  • [31] Impact of the limited oxygen availability on the localized fire development in a large-area building compartment
    Maslak, Mariusz
    Pazdanowski, Michal
    Wozniczka, Piotr
    FIRE PROTECTION, SAFETY AND SECURITY 2017, 2017, : 106 - 116
  • [32] FIRE VENTILATION
    TEWARSON, A
    STECIAK, J
    COMBUSTION AND FLAME, 1983, 53 (1-3) : 123 - 134
  • [33] Simulation of the Fire Process in a Highway Tunnel under Vertical Ventilation
    Chang Yufeng
    Xu Zhisheng
    Jia Pei
    Hu Zilin
    PROCEEDINGS OF THE 2010 CHINESE SEMINAR ON THE PRINCIPLES OF SAFETY SCIENCE AND TECHNOLOGY, 2010, : 481 - 486
  • [34] Natural ventilation of residential building Atrium under fire scenario
    Al-Waked, Rafat
    Nasif, Mohammad
    Groenhout, Nathan
    Partridge, Lester
    CASE STUDIES IN THERMAL ENGINEERING, 2021, 26
  • [35] Fire Compartment and Fire Barrier Evaluation in the NPP Fire PSA
    Wu, Yue
    PROCEEDINGS OF THE 20TH PACIFIC BASIN NUCLEAR CONFERENCE, VOL 1, 2017, : 351 - 363
  • [36] ACCURACY OF 2 ZONE COMPARTMENT FIRE MODELS FOR THE CALCULATION OF FIRE CONSEQUENCES IN AN INDUSTRIAL COMPARTMENT
    RONGERE, FX
    REVUE GENERALE DE THERMIQUE, 1988, 27 (315-16): : 256 - 261
  • [37] Experimental study of natural roof ventilation in full-scale enclosure fire tests in a small compartment
    Merci, Bart
    Vandevelde, Paul
    FIRE SAFETY JOURNAL, 2007, 42 (08) : 523 - 535
  • [38] Experimental Study of Temperature Profile in Underground Corridor of Different Ventilation Conditions Induced by Fire in an Adjacent Compartment
    State Key Laboratory of Fire Science, University of Science and Technology of China, Anhui, Hefei, China
    不详
    不详
    1600,
  • [39] Experimental study of temperature profile in underground corridor of different ventilation conditions induced by fire in an adjacent compartment
    Chen, Xiaotao
    Sun, Xiepeng
    Zhang, Xiaolei
    Fang, Xiang
    Yi, Jiwei
    Hu, Longhua
    TUNNELLING AND UNDERGROUND SPACE TECHNOLOGY, 2024, 154
  • [40] Thermal and spectral analysis of a pool fire in an engine compartment: Experimental study on the influence of ventilation and fuel depth
    Robinet, Antonin
    Chetehouna, Khaled
    Junjunan, Soleh
    Cable, Axel
    Oger, Antoine
    PROCESS SAFETY AND ENVIRONMENTAL PROTECTION, 2023, 174 : 200 - 213