Loose intra-articular body following anterior cruciate ligament reconstruction

被引:18
|
作者
Cossey, AJ [1 ]
Paterson, RS [1 ]
Orth, FA [1 ]
机构
[1] SportsMed SA, Stepney, SA 5069, Australia
关键词
loose body; ACL reconstruction; bioabsorbable fixation;
D O I
10.1016/j.arthro.2004.11.010
中图分类号
R826.8 [整形外科学]; R782.2 [口腔颌面部整形外科学]; R726.2 [小儿整形外科学]; R62 [整形外科学(修复外科学)];
学科分类号
摘要
We report a case of intra-articular fracture of a bioabsorbable fixation device from the femoral tunnel in an anterior cruciate ligament reconstruction using a bone-tendon-bone graft. Thirteen months after successful reconstruction surgery, the patient experienced episodes of locking and medial joint pain. There was no history of trauma and no symptoms of instability or swelling. On revision arthroscopy, a fractured tip of a bioabsorbable RIGIDfix cross pin (Mitek, Westwood, MA) was identified in the medial compartment of the knee. There was a broad area of chondral erosion affecting the medial femoral condyle and a small defect to the medial tibial plateau where the loose body had been lodged. The bone-tendon-bone graft was intact without disruption. After arthroscopy, the patient was symptom free for 3 weeks but then developed further symptoms of locking. Magnetic resonance imaging showed another loose body within the knee. A repeat arthroscopy was performed 6 weeks after the earlier procedure and another piece of the polylactic acid RIGIDfix cross pin was removed, this time from the lateral gutter. This case raises concern about the potential for breakage and resultant loose body formation that may occur after bioabsorbable cross-pin fixation and, particularly, the associated chondral damage that can occur if early intervention is not conducted.
引用
收藏
页码:348 / 350
页数:3
相关论文
共 50 条
  • [31] INTRA-ARTICULAR RECONSTRUCTION OF THE ANTERIOR CRUCIATE LIGAMENT - AN EXPERIMENTAL-STUDY OF LENGTH CHANGES IN DIFFERENT LIGAMENT RECONSTRUCTIONS
    HOOGLAND, T
    HILLEN, B
    CLINICAL ORTHOPAEDICS AND RELATED RESEARCH, 1984, (185) : 197 - 202
  • [32] Sex-Specific Predictors of Intra-articular Injuries Observed During Anterior Cruciate Ligament Reconstruction
    Kluczynski, Melissa A.
    Marzo, John M.
    Rauh, Michael A.
    Bernas, Geoffrey A.
    Bisson, Leslie J.
    ORTHOPAEDIC JOURNAL OF SPORTS MEDICINE, 2015, 3 (02) : 1 - 9
  • [33] Intra-articular detachment of the endobutton more than 18 months after anterior cruciate ligament reconstruction
    Muneta, T
    Yagishita, K
    Kurihara, Y
    Sekiya, I
    ARTHROSCOPY, 1999, 15 (07): : 775 - 778
  • [34] Intra-articular anterior cruciate ligament reconstruction using patellar tendon allograft in the skeletally immature patient
    Fuchs, R
    Wheatley, W
    Uribe, JW
    Hechtman, KS
    Zvijac, JE
    Schurhoff, MR
    ARTHROSCOPY-THE JOURNAL OF ARTHROSCOPIC AND RELATED SURGERY, 2002, 18 (08): : 824 - 828
  • [35] Biomechanical evaluation of intra-articular and extra-articular procedures in anterior cruciate ligament reconstruction: A finite element analysis
    Ramaniraka, N. A.
    Saunier, P.
    Siegrist, O.
    Pioletti, D. P.
    CLINICAL BIOMECHANICS, 2007, 22 (03) : 336 - 343
  • [36] Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction
    A. Werner
    A. Wild
    A. Ilg
    R. Krauspe
    Knee Surgery, Sports Traumatology, Arthroscopy, 2002, 10 : 30 - 32
  • [37] Secondary intra-articular dislocation of a broken bioabsorbable interference screw after anterior cruciate ligament reconstruction
    Werner, A
    Wild, A
    Ilg, A
    Krauspe, R
    KNEE SURGERY SPORTS TRAUMATOLOGY ARTHROSCOPY, 2002, 10 (01) : 30 - 32
  • [38] Cruciate ligament graft intra-articular distances
    Miller, MD
    Olszewski, AD
    ARTHROSCOPY, 1997, 13 (03): : 291 - 295
  • [39] A comparison of isokinetics and muscle strength ratios following intra-articular and extra-articular reconstructions of the anterior cruciate ligament
    Oni, OOA
    Crowder, E
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 1996, 27 (03): : 195 - 197
  • [40] Efficacy of preoperative intra-articular morphine analgesia for anterior cruciate ligament repair
    Vitale, G
    Marino, MR
    Frachini, N
    Sparacino, ME
    Bigoni, M
    Randelli, P
    Denti, M
    Giurati, G
    Pesenti, A
    BRITISH JOURNAL OF ANAESTHESIA, 1996, 76 : A380 - A380