摘要
Study Design: Biontechanical study of pullout strength of unicortical versus bicortical C1 lateral mass screws using a cadaveric cervical spine model. Objective: To compare pullout strength of unicortical versus bicortical Cl lateral mass screws. Summary of Background Data: The internal carotid artery and hypoglossal nerve lie over the anterior aspect of the lateral mass of the atlas and are at risk from bicortical Cl lateral mass screws. Unicortical screws would reduce the risk of injury to these neurovascular structures; however, no data are available on the relative strength of unicortical versus bicortical C1 lateral mass screws. Methods: Fifteen cadaveric cervical spine specimens underwent axial pullout testing of Cl lateral mass screws. A unicortical Cl lateral mass screw was placed on I side with a contralateral bicortical screw. Results: The mean pullout strengths of the unicortical screws and bicortical screws were 588N (range, 212 to 1234N) and 807 N (range, 163 to 1460 N), respectively (P = 0.008). Conclusions: Bicortical C I lateral mass screws were significantly stronger than unicortical screws; however, the mean pullout strength of both the unicortical and bicortical Cl screws were greater than previously reported values for subaxial lateral mass screws. On the basis of these data, the clinical necessity for using bicortical screw fixation in all patients must be questioned. If similar strength can be achieved using unicortical C1 lateral mass screw to that currently accepted in the subaxial spine, bicortical screws might not be justified for the C I lateral mass. However, the ability to extrapolate C1-C2 data to subaxial spine data is uncertain because of the difference in normal physiologic loading at these levels.
引用
收藏
页码:505 / 508
页数:4
相关论文
共 50 条
  • [21] Comparison of Transarticular Screw Fixation and C1 Lateral Mass-C2 Pedicle Screw Fixation in Patients with Rheumatoid Arthritis with Atlantoaxial Instability
    Ryu, Je Il
    Bak, Koang Hum
    Kim, Jae Min
    Chun, Hyoung-Joon
    WORLD NEUROSURGERY, 2017, 99 : 179 - 185
  • [22] Unicortical and bicortical plating in the fixation of comminuted fractures of the clavicle: a biomechanical study
    Looft, John M.
    Correa, Lincoln
    Patel, Minoo
    Rawlings, Mathew
    Ackland, David C.
    ANZ JOURNAL OF SURGERY, 2017, 87 (11) : 915 - 920
  • [23] Biomechanical Comparison of Bicortical, Unicortical, and Unicortical Far-Cortex-Abutting Screw Fixations in Plated Comminuted Midshaft Clavicle Fractures
    Croley, J. Sawyer
    Morris, Randal P.
    Amin, Arsalan
    Lindsey, Ronald W.
    Gugala, Zbigniew
    JOURNAL OF HAND SURGERY-AMERICAN VOLUME, 2016, 41 (06): : 703 - 711
  • [24] C2 Nerve Dysfunction Associated with C1 Lateral Mass Screw Fixation
    Huang, Da-geng
    Hao, Ding-jun
    Li, Guang-lin
    Guo, Hao
    Zhang, Yu-chen
    He, Bao-rong
    ORTHOPAEDIC SURGERY, 2014, 6 (04) : 269 - 273
  • [25] Anatomic Consideration of the C1 Laminar Arch for Lateral Mass Screw Fixation via C1 Lateral Lamina : A Landmark between the Lateral and Posterior Lamina of the C1
    Kim, Jung-Hwan
    Kwak, Dai-Soon
    Han, Seung-Ho
    Cho, Sung-Min
    You, Seung-Hoon
    Kim, Moon-Kyu
    JOURNAL OF KOREAN NEUROSURGICAL SOCIETY, 2013, 54 (01) : 25 - 29
  • [26] Unicortical versus bicortical plate fixation for midshaft clavicular fractures
    Ernesto Zaidenberg, Ezequiel
    Andres Rossi, Luciano
    Francisco, Federico
    Tanoira, Ignacio
    Pasqualini, Ignacio
    Ranalletta, Maximiliano
    Rodolfo Zaidenberg, Carlos
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2023, 54
  • [27] Characteristics of unicortical and bicortical lateral mass screws in the cervical spine
    Seybold, EA
    Baker, JA
    Criscitiello, AA
    Ordway, NR
    Park, CK
    Connolly, PJ
    SPINE, 1999, 24 (22) : 2397 - 2403
  • [28] Biomechanical properties of off-axis screw in Pauwels III femoral neck fracture fixation: Bicortical screw construct is superior to unicortical screw construct
    Kuan, Fa-Chuan
    Hsu, Kai-Lan
    Lin, Cheng-Li
    Hong, Chih-Kai
    Yeh, Ming-Long
    Su, Wei-Ren
    INJURY-INTERNATIONAL JOURNAL OF THE CARE OF THE INJURED, 2019, 50 (11): : 1889 - 1894
  • [29] Biomechanical comparison of the pullout strengths of C1 lateral mass screws and C1 posterior arch screws
    Zarro, Christopher M.
    Ludwig, Steven C.
    Hsieh, Adam H.
    Seal, Charles N.
    Gelb, Daniel E.
    SPINE JOURNAL, 2013, 13 (12): : 1892 - 1896
  • [30] Motion-preserving reduction and fixation of C1 Jefferson fracture using a C1 lateral mass screw construct
    Jo, Kwang-Wook
    Park, Ik-Seong
    Hong, Jae Taek
    JOURNAL OF CLINICAL NEUROSCIENCE, 2011, 18 (05) : 695 - 698