Nanomolar detection of hydrogen peroxide on glassy carbon electrode modified with electrodeposited cobalt oxide nanoparticles

被引:296
|
作者
Salimi, Abdollah
Hallaj, Rahman
Soltanian, Saied
Mamkhezri, Hussein
机构
[1] Univ Kurdistan, Dept Chem, Sanandaj, Iran
[2] Univ Kurdistan, Res Ctr Nanotechnol, Sanandaj, Iran
关键词
electrodeposition; cobalt oxide; nanoparticles; cyclic voltammetry; electrocatalysis; H2O2; oxidation; AMPEROMETRIC SENSOR; ELECTROCHEMICAL DEPOSITION; OXYGEN EVOLUTION; GLUCOSE-OXIDASE; THIN-FILMS; BIOSENSOR; OXIDATION; REDUCTION; COMPOSITE; GOLD;
D O I
10.1016/j.aca.2007.05.010
中图分类号
O65 [分析化学];
学科分类号
070302 ; 081704 ;
摘要
The electrochemical detection of H2O2 was investigated on a cobalt oxide nanoparticles modified glassy carbon electrode in phosphate buffer solution (pH 7). Cyclic voltammetry at potential range - 1.1 to 1.1 V from CoCl2 natural aqueous solution produced well defined cobalt oxide nanopaparticles deposited on the surface of glassy carbon electrode. The surface of resulting electrode was characterized with SEM. The formation of cobalt oxyhydroxide film was investigated by cyclic voltammetry in alkaline and natural aqueous solution. The modified electrode showed well defined and stable redox couples in both alkaline and natural aqueous solution. The modified electrode showed excellent electrocatalytic activity for oxidation of hydrogen peroxide. The response to H2O2 on the modified electrode was examined using cyclic voltammetry and amperometry. The amperometric detection of hydrogen peroxide is carried out at 0.75 V versus Ag/AgCl reference electrode in phosphate buffer solution with pH 7.4. The detection limit (S/N = 3) was 0.4 nM with linearity up to 6 orders of magnitude and sensitivity of 4.86 mu A mu M-1 cm(-2). The response time of the electrode to achieve 95% of the steady-state current is <2 s. No measurable reduction in analytical performance of the modified electrode was found by storing the electrode in ambient conditions for 20 days. This modified electrode recedes many advantages such as remarkable catalytic activity, good reproducibility, simple preparation procedure and long term stability of signal response during hydrogen peroxide oxidation. The immobilization of cobalt oxide nanoparticles on the surface of GC electrode appears to be a highly efficient method for the development of a new class of sensitive, stable and reproducible hydrogen peroxide electrochemical sensor. (c) 2007 Elsevier B.V. All rights reserved.
引用
收藏
页码:24 / 31
页数:8
相关论文
共 50 条
  • [1] Cobalt oxide nanoparticles electrodeposited on glassy carbon electrode for metronidazole determination
    Delnavaz, Elnaz
    Asadpour-Zeynali, Karim
    RESULTS IN CHEMISTRY, 2024, 7
  • [2] Nanomolar detection of guanine based on a novel cobalt oxide nanostructure-modified glassy carbon electrode
    Hallaj, Rahman
    Salimi, Abdollah
    ANALYTICAL METHODS, 2011, 3 (04) : 911 - 918
  • [3] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    Noor, An'amt Mohamed
    Shahid, Muhammad Mehmood
    Rameshkumar, Perumal
    Huang, Nay Ming
    MICROCHIMICA ACTA, 2016, 183 (02) : 911 - 916
  • [4] A glassy carbon electrode modified with graphene oxide and silver nanoparticles for amperometric determination of hydrogen peroxide
    An’amt Mohamed Noor
    Muhammad Mehmood Shahid
    Perumal Rameshkumar
    Nay Ming Huang
    Microchimica Acta, 2016, 183 : 911 - 916
  • [5] Modified glassy carbon electrode based on myoglobin and reduced graphene oxide for hydrogen peroxide detection
    Szoke, A.
    Turdean, G.
    Muresan, L.
    BULGARIAN CHEMICAL COMMUNICATIONS, 2017, 49 : 147 - 154
  • [6] Biomimetic behavior and nanomolar detection of hydrogen peroxide on an electrochemically pre-treated hematin modified glassy carbon electrode
    Buoro, Rafael M.
    Bacil, Raphael P.
    Sanz, Caroline G.
    Campos, Othon S.
    Serrano, Silvia H. P.
    SENSORS AND ACTUATORS B-CHEMICAL, 2017, 250 : 169 - 178
  • [7] Sensitive amperometric detection of omeprazole and pantoperazole at electrodeposited nickel oxide nanoparticles modified glassy carbon electrode
    Abdollah Salimi
    Zahra Enferadi
    Abdollah Noorbakhash
    Kayomars Rashidi
    Journal of Solid State Electrochemistry, 2012, 16 : 1369 - 1375
  • [8] Sensitive amperometric detection of omeprazole and pantoperazole at electrodeposited nickel oxide nanoparticles modified glassy carbon electrode
    Salimi, Abdollah
    Enferadi, Zahra
    Noorbakhash, Abdollah
    Rashidi, Kayomars
    JOURNAL OF SOLID STATE ELECTROCHEMISTRY, 2012, 16 (04) : 1369 - 1375
  • [9] A novel hydrogen peroxide sensor based on Ag nanoparticles electrodeposited on DNA-networks modified glassy carbon electrode
    Cui, Kang
    Song, Yonghai
    Yao, Yong
    Huang, Zhenzhong
    Wang, Li
    ELECTROCHEMISTRY COMMUNICATIONS, 2008, 10 (04) : 663 - 667
  • [10] Sensing hydrogen peroxide with a glassy carbon electrode modified with silver nanoparticles, AlOOH and reduced graphene oxide
    Ziyin Yang
    Chengcheng Qi
    Xiaohui Zheng
    Jianbin Zheng
    Microchimica Acta, 2016, 183 : 1131 - 1136