Validity of the modified Conconi test for determining ventilatory threshold during on-water rowing

被引:1
|
作者
Villamil Cabo, Jorge [1 ]
Martinez-Camblor, Pablo [2 ]
del Valle, Miguel [1 ,3 ]
机构
[1] Univ Oviedo, Sport Med Sch, Oviedo, Spain
[2] Univ Oviedo, Biosanitary Res Off Asturias, Dept Stat, Oviedo, Spain
[3] Univ Oviedo, Morphol & Funct Biol Dept, Oviedo, Spain
关键词
Field test; anaerobic threshold heart rate; ventilatory threshold; RATE DEFLECTION POINT; STEADY-STATE EXERCISE; HEART-RATE; ANAEROBIC THRESHOLD; LACTATE THRESHOLD; INCREMENTAL EXERCISE; NONINVASIVE DETERMINATION; STATISTICAL-METHODS; ERGOMETER EXERCISE; FIELD-TEST;
D O I
暂无
中图分类号
G8 [体育];
学科分类号
04 ; 0403 ;
摘要
The objectives of this study were to design a field test based on the Conconi protocol to determine the ventilatory threshold of rowers and to test its reliability and validity. A group of sixteen oarsmen completed a modified Conconi test for on-water rowing. The reliability of the detection of the heart rate threshold was evaluated using heart rate breaking point in the Conconi test and retest. Heart rate threshold was detected in 88.8% of cases in the test-retest. The validity of the modified Conconi test was evaluated by comparing the heart rate threshold data acquired with that obtained in a ventilatory threshold test (VT2). No significant differences were found for the values of different intensity parameters i.e. heart rate (HR), oxygen consumption (VO2), stroke rate (SR) and speed (S) between the heart rate threshold and the ventilatory threshold, (170.9 +/- 6.8 vs. 169.3 +/- 6.4 beats.min(-1); 42.0 +/- 8.6 vs. 43.5 +/- 8.3 ml.kg(-1).min(-1); 25.8 +/- 3.3 vs. 27.0 +/- 3.2 strokes.min(-1) and 14.4 +/- 0.8 vs. 14.6 +/- 0.8 km.h(-1)). The differences in averages obtained in the Conconi test-retest were small with a low standard error of the mean. The reliability data between the Conconi test-retest showed low coefficients of variations (CV) and high intraclass correlation coefficients (ICC). The total errors for the Conconi test-retest are low for the measured variables (1.31 HR, 0.87 VO2, 0.65 SR, and 0.1 S). The Bland-Altman's method for analysis validity showed a strong concordance according to the analyzed variables. We conclude that the modified Conconi test for on-water rowing is a valid and reliable method for the determination of the second ventilatory threshold (VT2).
引用
收藏
页码:616 / 623
页数:8
相关论文
共 34 条
  • [31] A modified differential scanning calorimetry method for determining water transport properties in biological cells during the freezing process
    Han, Xu
    Luo, Dawei
    Cui, Xiangdong
    Heimfeld, Shelly
    Gao, Dayong
    CELL PRESERVATION TECHNOLOGY, 2007, 5 (01): : 25 - 32
  • [32] Reliability and validity of heart rate variability threshold assessment during an incremental shuttle-walk test in middle-aged and older adults
    Dourado, V. Z.
    Guerra, R. L. F.
    BRAZILIAN JOURNAL OF MEDICAL AND BIOLOGICAL RESEARCH, 2013, 46 (02) : 194 - 199
  • [33] Tracing of stresses and pore water pressure changes during a multistage modified relaxation test model on organic soil
    Fattah M.Y.
    Al-Omari R.R.
    Hameedi M.K.
    Arabian Journal of Geosciences, 2021, 14 (19)
  • [34] Interobserver and intraobserver reliabilities of determining the ventilatory thresholds in subjects with a lower limb amputation and able-bodied subjects during a peak exercise test on the combined arm-leg (Cruiser) ergometer
    Simmelink, Elisabeth K.
    Dijkstra, Pieter U.
    de Bruijn, Matthijs C.
    Geertzen, Jan H. B.
    van der Woude, Lucas H., V
    Wempe, Johan B.
    Dekker, Rienk
    INTERNATIONAL JOURNAL OF REHABILITATION RESEARCH, 2022, 45 (03) : 243 - 252