Development of ultra-fast X-ray computed tomography scanner system

被引:0
|
作者
Hori, K [1 ]
Fujimoto, T [1 ]
Kawanishi, K [1 ]
机构
[1] Mitsubishi Heavy Ind Ltd, Takasago Res & Dev Ctr, Takasago, Hyogo 676, Japan
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development of ultra-fast X-ray computed tomography (CT) scanner system has been performed. This system can operate under the scanning time of 0.5 millisecond/slice and give 2000 slices/second. The original object of interest is in a transient or unsettled state of multiphase flow to measure the instantaneous phase distribution. An improvement of scanning speed was required to reduce the effects of motion artifact. The mechanical motion mechanism of conventional CT scanner is a major obstacle to improve the scanning speed. Therefor, the concept of electrical switching electron beam is adopted to reduce the scanning time. The developed present system has stationary 60 X-ray tubes and stationary 584 cadmium telluride (CdTe) semiconductor detectors. The excellent performance to the measurement and visualization of dynamic events of multiphase flow is confirmed by measuring the moving acrylic resin phantoms and the air-water two phase flow in a tube or a 3x3 rod bundle. And, the feasibility is demonstrated to the medical field by trial application for the movement of dog's heart, though the requirement remains to improve the image quality. It was confirmed by a simulation that the improvement will be performed by increasing the number of projections.
引用
收藏
页码:1003 / 1008
页数:6
相关论文
共 50 条
  • [21] Design and optimization of a parallel spectrometer for ultra-fast X-ray science
    Braig, Christoph
    Loechel, Heike
    Mitzner, Rolf
    Quevedo, Wilson
    Loukas, Panagiotis
    Kubin, Markus
    Weniger, Christian
    Firsov, Alexander
    Rehanek, Jens
    Brzhezinskaya, Maria
    Wernet, Philippe
    Foehlisch, Alexander
    Erko, Alexei
    OPTICS EXPRESS, 2014, 22 (10): : 12583 - 12602
  • [22] Ultra-fast flash X-ray pulses produced by Blumlein devices
    Davanloo, F
    Collins, CB
    Agee, FJ
    NUCLEAR INSTRUMENTS & METHODS IN PHYSICS RESEARCH SECTION B-BEAM INTERACTIONS WITH MATERIALS AND ATOMS, 2005, 241 (1-4): : 276 - 280
  • [23] Brightness optimization of ultra-fast Thomson scattering x-ray sources
    Brown, WJ
    Hartemann, FV
    ADVANCED ACCELERATOR CONCEPTS, 2004, 737 : 839 - 845
  • [25] Fast optimization of coded apertures in X-ray computed tomography
    Mao, Tianyi
    Cuadros, Angela P.
    Ma, Xu
    He, Weiji
    Chen, Qian
    Arce, Gonzalo R.
    OPTICS EXPRESS, 2018, 26 (19): : 24461 - 24478
  • [26] A hybrid approach for fast simulation of x-ray computed tomography
    Ay, M. R.
    Gafarian, P.
    Zaidi, H.
    2007 IEEE NUCLEAR SCIENCE SYMPOSIUM CONFERENCE RECORD, VOLS 1-11, 2007, : 3155 - +
  • [27] NONDESTRUCTIVE TESTING OF GRAPHITES USING X-RAY COMPUTED-TOMOGRAPHY SCANNER
    IOKA, I
    YODA, S
    FUJII, M
    OKU, T
    TANAKA, T
    JOURNAL OF THE ATOMIC ENERGY SOCIETY OF JAPAN, 1986, 28 (06): : 534 - 542
  • [28] Two-ply anode X-ray tube for computed tomography scanner
    Ignatyev, D.
    Taubin, M.
    Chesnokov, D.
    Malyshev, V.
    Yaskolko, A.
    10TH INTERNATIONAL SCHOOL-CONFERENCE ON MATERIALS FOR EXTREME ENVIRONMENT: DEVELOPMENT, PRODUCTION AND APPLICATION (MEEDPA10), 2016, 130
  • [29] Spectral X-ray computed tomography scanner using a cadmium telluride detector
    Sato, Eiichi
    Oda, Yasuyuki
    Yamaguchi, Satoshi
    Hagiwara, Osahiko
    Matsukiyo, Hiroshi
    Watanabe, Manabu
    Kusachi, Shinya
    RADIATION DETECTORS: SYSTEMS AND APPLICATIONS XVII, 2016, 9969
  • [30] X-ray Computed Tomography for the Development of Ballistic Composite
    Ziolkowski, Grzegorz
    Pach, Joanna
    Pyka, Dariusz
    Kurzynowski, Tomasz
    Jamroziak, Krzysztof
    MATERIALS, 2020, 13 (23) : 1 - 19