Development of ultra-fast X-ray computed tomography scanner system

被引:0
|
作者
Hori, K [1 ]
Fujimoto, T [1 ]
Kawanishi, K [1 ]
机构
[1] Mitsubishi Heavy Ind Ltd, Takasago Res & Dev Ctr, Takasago, Hyogo 676, Japan
关键词
D O I
暂无
中图分类号
TH7 [仪器、仪表];
学科分类号
0804 ; 080401 ; 081102 ;
摘要
The development of ultra-fast X-ray computed tomography (CT) scanner system has been performed. This system can operate under the scanning time of 0.5 millisecond/slice and give 2000 slices/second. The original object of interest is in a transient or unsettled state of multiphase flow to measure the instantaneous phase distribution. An improvement of scanning speed was required to reduce the effects of motion artifact. The mechanical motion mechanism of conventional CT scanner is a major obstacle to improve the scanning speed. Therefor, the concept of electrical switching electron beam is adopted to reduce the scanning time. The developed present system has stationary 60 X-ray tubes and stationary 584 cadmium telluride (CdTe) semiconductor detectors. The excellent performance to the measurement and visualization of dynamic events of multiphase flow is confirmed by measuring the moving acrylic resin phantoms and the air-water two phase flow in a tube or a 3x3 rod bundle. And, the feasibility is demonstrated to the medical field by trial application for the movement of dog's heart, though the requirement remains to improve the image quality. It was confirmed by a simulation that the improvement will be performed by increasing the number of projections.
引用
收藏
页码:1003 / 1008
页数:6
相关论文
共 50 条
  • [1] Development of ultra-fast X-ray computed tomography scanner system
    Hori, K
    Fujimoto, T
    Kawanishi, K
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1998, 45 (04) : 2089 - 2094
  • [2] Development of ultra-fast X-ray computed tomography scanner system
    Mitsubitshi Heavy Industries, Ltd, Takasago, Japan
    IEEE Trans Nucl Sci, 4 pt 2 (2089-2094):
  • [3] An ultra fast electron beam x-ray tomography scanner
    Fischer, F.
    Hoppe, D.
    Schleicher, E.
    Mattausch, G.
    Flaske, H.
    Bartel, R.
    Hampel, U.
    MEASUREMENT SCIENCE AND TECHNOLOGY, 2008, 19 (09)
  • [4] ULTRA-FAST X-RAY STREAK CAMERA
    COLEMAN, LW
    MCCONAGHY, CF
    SMPTE JOURNAL, 1976, 85 (01): : 26 - 26
  • [5] TENDERING FOR AN X-RAY COMPUTED-TOMOGRAPHY SCANNER
    EDYVEAN, S
    PERRY, BJ
    BRITISH JOURNAL OF RADIOLOGY, 1987, 60 (716): : 834 - 834
  • [6] Description of a transmission X-ray computed tomography scanner
    Hamideen, M. S.
    Sharaf, J.
    Al-Saleh, K. A.
    Shaderma, M.
    RADIATION PHYSICS AND CHEMISTRY, 2011, 80 (11) : 1162 - 1165
  • [7] COMPUTED TOMOGRAPHY WITH AN X-RAY TRANSMISSION PENCIL BEAM SCANNER
    KAMBIC, GX
    WAKE, RH
    IEEE TRANSACTIONS ON NUCLEAR SCIENCE, 1977, 24 (02) : 874 - 880
  • [8] Development of Carbon Nanotube X-ray System for Computed Tomography
    Ryu, Je Hwang
    Lee, Seung Ho
    Kim, Wan Sun
    Eom, Young Ju
    Kim, Jae Gon
    Lee, Soo Yeol
    Park, Kyu Chang
    Park, Hun Kuk
    2012 25TH INTERNATIONAL VACUUM NANOELECTRONICS CONFERENCE (IVNC), 2012, : 402 - +
  • [9] Ultra-fast x-ray tomography for multi-phase flow interface dynamic studies
    Misawa, M.
    Tiseanu, I
    Prasser, H-M
    Ichikawa, N.
    Akai, M.
    KERNTECHNIK, 2003, 68 (03) : 85 - 90
  • [10] X-ray Evidence for Ultra-Fast Outflows in Local AGNs
    Tombesi, F.
    Cappi, M.
    Sambruna, R. M.
    Reeves, J. N.
    Reynolds, C. S.
    Braito, V.
    Dadina, M.
    AGN WINDS IN CHARLESTON, 2012, 460 : 8 - +