Quality assessment of CNES real-time ionospheric products

被引:47
|
作者
Nie, Zhixi [1 ]
Yang, Hongzhou [1 ]
Zhou, Peiyuan [1 ]
Gao, Yang [1 ]
Wang, Zhenjie [2 ]
机构
[1] Univ Calgary, Schulich Sch Engn, Calgary, AB, Canada
[2] China Univ Petr, Sch Geosci, Qingdao, Peoples R China
基金
中国国家自然科学基金;
关键词
Real time; SF-PPP; CNES; VTEC; STEC;
D O I
10.1007/s10291-018-0802-2
中图分类号
TP7 [遥感技术];
学科分类号
081102 ; 0816 ; 081602 ; 083002 ; 1404 ;
摘要
Real-time single-frequency precise point positioning (RT-SF-PPP) has become a desired positioning approach because it can achieve high positioning accuracy with a low-cost global navigation satellite system (GNSS) chipset or receiver. For single-frequency precise point positioning (SF-PPP) applications, the ionospheric delay is a dominant error source, and thus the quality of applied ionospheric products is critical to the performance of SF-PPP. To meet the demands of the RT-SF-PPP users, the international GNSS service (IGS) is planning to provide open-access real-time ionospheric products. By now, the Centre National d'Etudes Spatiales (CNES) is the only IGS analysis center (AC) to broadcast real-time ionospheric vertical total electron content (VTEC) message through its real-time service (RTS). The quality of the CNES real-time ionospheric products is drawing increasing attention from the GNSS community. We evaluate the quality of CNES real-time VTEC message both in the ionospheric correction domain and positioning domain. First, 374 consecutive days of CNES VTEC products are collected and compared with the IGS final global ionospheric map (GIM) products. Second, slant total electron content (STEC) computed with CNES VTEC message is fully assessed with respect to STEC derived from dual-frequency GNSS measurements. Finally, RT-SF-PPP is conducted for assessing the quality of CNES real-time ionospheric products in the positioning domain. The degree and order of the spherical harmonic expansions broadcasted in the CNES VTEC messages changed from 6 to 12 in the time span of collected data, the effects of higher degree and order parameters are investigated at the same time in the experiments above.
引用
收藏
页数:15
相关论文
共 50 条
  • [41] Quality of dual frequency ionospheric real time corrections
    Engler, E
    Jungstand, A
    Klahn, D
    PROCEEDINGS OF THE 52ND ANNUAL MEETING - THE INSTITUTE OF NAVIGATION: NAVIGATIONAL TECHNOLOGY FOR THE 3RD MILLENNIUM, 1996, : 157 - 165
  • [42] REAL-TIME ANALYSIS OF DETONATION PRODUCTS
    BLAIS, NC
    GREINER, NR
    FERNANDEZ, W
    PROCEEDINGS OF THE INTERNATIONAL SYMPOSIUM ON PYROTECHNICS AND EXPLOSIVES, OCTOBER 12-15, 1987, BEIJING, CHINA, 1987, : 469 - 474
  • [43] Real-time technology assessment
    Guston, David H.
    Sarewitz, Daniel
    Technology in Society, 2002, 24 (1-2) : 93 - 109
  • [44] A new quality monitoring method for real-time precise orbit and clock products
    Xue, Yu
    Zheng, Fu
    Zhou, Guangyu
    Chao, Wenyue
    Zhang, Dong
    Shi, Chuang
    GPS SOLUTIONS, 2024, 28 (03)
  • [45] Vision-based, Real-time Retinal Image Quality Assessment
    Davis, Herbert
    Russell, Stephen
    Barriga, Eduardo
    Abramoff, Michael
    Soliz, Peter
    2009 22ND IEEE INTERNATIONAL SYMPOSIUM ON COMPUTER-BASED MEDICAL SYSTEMS, 2009, : 402 - +
  • [46] Assessment of real-time electrocardiogram effects on interpretation quality by emergency physicians
    Perrichot, Alice
    Ayar, Pradeebane Vaittinada
    Taboulet, Pierre
    Choquet, Christophe
    Gay, Matthieu
    Casalino, Enrique
    Steg, Philippe Gabriel
    Curac, Sonja
    Ayar, Prabakar Vaittinada
    BMC MEDICAL EDUCATION, 2023, 23 (01)
  • [47] Doppler Centroid Estimation with Quality Assessment for Real-Time SAR Imaging
    Lee, Yu-Chieh
    Tsai, Pei-Yun
    Lee, Sz-Yuan
    2020 ASIA-PACIFIC SIGNAL AND INFORMATION PROCESSING ASSOCIATION ANNUAL SUMMIT AND CONFERENCE (APSIPA ASC), 2020, : 36 - 40
  • [48] Hybrid Real-time Quality Assessment Model for Voice over IP
    Han, Yi
    Muntean, Gabriel-Miro
    2015 IEEE INTERNATIONAL SYMPOSIUM ON BROADBAND MULTIMEDIA SYSTEMS AND BROADCASTING (BMSB), 2015,
  • [49] IS REAL-TIME QUALITY ASSESSMENT OF HEALTH-CARE AN ACHIEVABLE GOAL
    TERREROS, DA
    ROBINSON, VJ
    HODSON, WL
    ANNALS OF CLINICAL AND LABORATORY SCIENCE, 1994, 24 (01): : 96 - 99
  • [50] Assessment of real-time electrocardiogram effects on interpretation quality by emergency physicians
    Alice Perrichot
    Pradeebane Vaittinada Ayar
    Pierre Taboulet
    Christophe Choquet
    Matthieu Gay
    Enrique Casalino
    Philippe Gabriel Steg
    Sonja Curac
    Prabakar Vaittinada Ayar
    BMC Medical Education, 23