Automatic segmentation of all lower limb muscles from high-resolution magnetic resonance imaging using a cascaded three-dimensional deep convolutional neural network

被引:39
|
作者
Ni, Renkun [1 ]
Meyer, Craig H. [2 ]
Blemker, Silvia S. [2 ]
Hart, Joseph M. [3 ]
Feng, Xue [1 ,2 ]
机构
[1] Springbok Inc, Charlottesville, VA 22903 USA
[2] Univ Virginia, Dept Biomed Engn, Charlottesville, VA 22904 USA
[3] Univ Virginia, Dept Kinesiol, Charlottesville, VA USA
基金
美国国家科学基金会;
关键词
lower limb muscle segmentation; magnetic resonance imaging; deep convolutional neural network; 3-D segmentation; cascaded network; LEG POWER; VOLUME; SHAPE;
D O I
10.1117/1.JMI.6.4.044009
中图分类号
R8 [特种医学]; R445 [影像诊断学];
学科分类号
1002 ; 100207 ; 1009 ;
摘要
High-resolution magnetic resonance imaging with fat suppression can obtain accurate anatomical information of all 35 lower limb muscles and individual segmentation can facilitate quantitative analysis. However, due to limited contrast and edge information, automatic segmentation of the muscles is very challenging, especially for athletes whose muscles are all well developed and more compact than the average population. Deep convolutional neural network (DCNN)-based segmentation methods showed great promise in many clinical applications, however, a direct adoption of DCNN to lower limb muscle segmentation is challenged by the large three-dimensional (3-D) image size and lack of the direct usage of muscle location information. We developed a cascaded 3-D DCNN model with the first step to localize each muscle using low-resolution images and the second step to segment it using cropped high-resolution images with individually trained networks. The work-flow was optimized to account for different characteristics of each muscle for improved accuracy and reduced training and testing time. A testing augmentation technique was proposed to smooth the segmentation contours. The segmentation performance of 14 muscles was within interobserver variability and 21 were slightly worse than humans. (c) 2019 Society of Photo-Optical Instrumentation Engineers (SPIE)
引用
收藏
页数:8
相关论文
共 50 条
  • [41] LONGITUDINAL MONITORING OF ANGIOGENESIS USING HIGH-RESOLUTION THREE-DIMENSIONAL ULTRASOUND IMAGING
    Mukai, K.
    Zhu, W.
    Nakajima, Y.
    Kobayashi, M.
    Nakatani, T.
    WOUND REPAIR AND REGENERATION, 2018, 26 (02) : A5 - A5
  • [42] Using carbon nanotube probes for high-resolution three-dimensional imaging of cells
    Koehne, J. E.
    Stevens, R. M.
    Zink, T.
    Deng, Z.
    Chen, H.
    Weng, I. C.
    Liu, F. T.
    Liu, G. Y.
    ULTRAMICROSCOPY, 2011, 111 (08) : 1155 - 1162
  • [43] Automatic Segmentation Algorithm of Magnetic Resonance Image in Diagnosis of Liver Cancer Patients under Deep Convolutional Neural Network
    Zhang, Jinling
    Yang, Jun
    Zhao, Min
    SCIENTIFIC PROGRAMMING, 2021, 2021
  • [44] MODELING FROM MAGNETIC RESONANCE IMAGING: AUTOMATIC CONSTRUCTION OF A THREE-DIMENSIONAL TONGUE COMPLEX
    Almeida, F. R.
    Pang, T.
    Chen, H.
    Fels, S.
    Combe, C.
    Teixeira, B.
    Lowe, A. A.
    Fleetham, J.
    SLEEP, 2009, 32 : A180 - A180
  • [45] Restore High-Resolution Nuclear Magnetic Resonance Spectra from Inhomogeneous Magnetic Fields Using a Neural Network
    Xiao, Xiongjie
    Wang, Qianqian
    Zhang, Xu
    Jiang, Bin
    Liu, Maili
    ANALYTICAL CHEMISTRY, 2023, 95 (45) : 16567 - 16574
  • [46] Deep convolutional neural networks for automatic segmentation of left ventricle cavity from cardiac magnetic resonance images
    Yang, Xulei
    Zeng, Zeng
    Yi, Su
    IET COMPUTER VISION, 2017, 11 (08) : 643 - 649
  • [47] High-resolution three-dimensional magnetic resonance imaging of the vestibular labyrinth in patients with atypical and intractable benign positional vertigo
    Schratzenstaller, B
    Wagner-Manslau, C
    Alexiou, C
    Arnold, W
    ORL-JOURNAL FOR OTO-RHINO-LARYNGOLOGY AND ITS RELATED SPECIALTIES, 2001, 63 (03): : 165 - 177
  • [48] Intractable and atypical benign paroxysmal vertigo. High-resolution three-dimensional magnetic resonance imaging of the vestibular organ
    Schratzenstaller, B
    Wagner-Manslau, C
    Strasser, G
    Arnold, W
    HNO, 2005, 53 (12) : 1063 - +
  • [49] Patient-Activated Three-Dimensional Multifrequency Magnetic Resonance Elastography for High-Resolution Mechanical Imaging of the Liver and Spleen
    Guo, J.
    Hirsch, S.
    Streitberger, K. J.
    Kamphues, C.
    Asbach, P.
    Braun, J.
    Sack, I.
    ROFO-FORTSCHRITTE AUF DEM GEBIET DER RONTGENSTRAHLEN UND DER BILDGEBENDEN VERFAHREN, 2014, 186 (03): : 260 - 266
  • [50] Fundus Changes in Highly Myopic Eyes with Different Shapes Identified by High-resolution Three-dimensional Magnetic Resonance Imaging
    Guo, Xinxing
    Xiao, Ou
    Chen, Yanxian
    He, Mingguang
    INVESTIGATIVE OPHTHALMOLOGY & VISUAL SCIENCE, 2015, 56 (07)