Uncertainty Quantification in Life Cycle Assessments Interindividual Variability and Sensitivity Analysis in LCA of Air-Conditioning Systems

被引:25
|
作者
Ross, Stephen A. [1 ]
Cheah, Lynette [1 ,2 ,3 ]
机构
[1] Singapore Univ Technol & Design, SUTD MIT Int Design Ctr, 8 Somapah Rd, Singapore 487372, Singapore
[2] SUTD Pillar Engn Syst & Design ESD, Singapore, Singapore
[3] IDC, Singapore, Singapore
关键词
eco-design; global warming potential; industrial ecology; Monte Carlo simulation; use-phase; user behavior; IMPACT ASSESSMENT; DECISION-ANALYSIS; NORMALIZATION; INFORMATION; KNOWLEDGE;
D O I
10.1111/jiec.12505
中图分类号
X [环境科学、安全科学];
学科分类号
08 ; 0830 ;
摘要
The life cycle environmental profile of energy-consuming products, such as air conditioning, is dominated by the products' use phase. Different user behavior patterns can therefore yield large differences in the results of a cradle-to-grave assessment. Although this variation and uncertainty is increasingly recognized, it remains often poorly characterized in life cycle assessment (LCA) studies. Today, pervasive sensing presents the opportunity to collect rich data sets and improve profiling of use-phase parameters, in turn facilitating quantification and reduction of this uncertainty in LCA. This study examined the case of energy use in building cooling systems, focusing on global warming potential (GWP) as the impact category. In Singapore, building cooling systems or air conditioning consumes up to 37% of national electricity demand. Lack of consideration of variation in use-phase interaction leads to the oversized designs, wasted energy, and therefore reducible GWP. Using a high-resolution data set derived from sensor observations, energy use and behavior patterns of single-office occupants were characterized by probabilistic distributions. The interindividual variability and use-phase variables were propagated in a stochastic model for the life cycle of air-conditioning systems and simulated by way of Monte Carlo analysis. Analysis of the generated uncertainties identified plausible reductions in global warming impact through modifying user interaction. Designers concerned about the environmental profile of their products or systems need better representation of the underlying variability in use-phase data to evaluate the impact. This study suggests that data can be reliably provided and incorporated into the life cycle by proliferation of pervasive sensing, which can only continue to benefit future LCA.
引用
收藏
页码:1103 / 1114
页数:12
相关论文
共 50 条
  • [21] Energy Audit Analysis of Residential Air-Conditioning Systems in Austin, Texas
    Rhodes, Joshua
    Stephens, Brent
    Webber, Michael E.
    ASHRAE TRANSACTIONS 2012, VOL 118, PT 1, 2012, 118 : 143 - 150
  • [22] An economic analysis of the integration between air-conditioning and solar photovoltaic systems
    Pires Leite, Gustavo de Novaes
    Weschenfelder, Franciele
    Araujo, Alex Mauricio
    Villa Ochoa, Alvaro Antonio
    Prestrelo Neto, Newton da Franca
    Kraj, Andrea
    ENERGY CONVERSION AND MANAGEMENT, 2019, 185 : 836 - 849
  • [23] Exergy analysis of two humidification process methods in air-conditioning systems
    Ghazikhani, M.
    Khazaee, I.
    Vahidifar, S.
    ENERGY AND BUILDINGS, 2016, 124 : 129 - 140
  • [24] Sizing heating, ventilating, and air-conditioning systems under uncertainty in both load-demand and capacity-supply side from a life-cycle aspect
    Huang, Pei
    Huang, Gongsheng
    Augenbroe, Godfried
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2017, 23 (02) : 367 - 381
  • [25] Hybrid uncertainty quantification method of internal disturbance parameters for reliability assessment of building air-conditioning design load
    Wu, Xia
    Tian, Zhe
    Niu, Jide
    Li, Xiaoyuan
    ENERGY AND BUILDINGS, 2023, 299
  • [26] COMPARISON OF LIFE CYCLE COST OF CENTRALIZED AND SPLIT AIR CONDITIONING SYSTEMS
    Hagare, Dharma
    Ho, Jason
    Saha, Swapan
    PROCEEDINGS OF INTERNATIONAL STRUCTURAL ENGINEERING AND CONSTRUCTION: INTERACTION BETWEEN THEORY AND PRACTICE IN CIVIL ENGINEERING AND CONSTRUCTION, 2016, : 621 - 626
  • [27] Thermodynamic analysis of capacity-control schemes for refrigeration and air-conditioning systems
    Yaqub, M
    Zubair, SM
    ENERGY, 1996, 21 (06) : 463 - 472
  • [28] Testing for Energy Recovery Ventilators and Energy Saving Analysis with Air-Conditioning Systems
    Yang, Peng
    Li, Li
    Wang, Jianqin
    Huang, Guilin
    Peng, Jingli
    9TH INTERNATIONAL SYMPOSIUM ON HEATING, VENTILATION AND AIR CONDITIONING (ISHVAC) JOINT WITH THE 3RD INTERNATIONAL CONFERENCE ON BUILDING ENERGY AND ENVIRONMENT (COBEE), 2015, 121 : 438 - 445
  • [29] Implications of uncertainty and variability in the life cycle assessment of pig production systems
    Basset-Mens, Claudine
    van der Werf, Hayo M. G.
    Durand, Patrick
    Leterme, Philippe
    INTERNATIONAL JOURNAL OF LIFE CYCLE ASSESSMENT, 2006, 11 (05): : 298 - 304
  • [30] Review of uncertainty-based design methods of central air-conditioning systems and future research trends
    Huang, Pei
    Wang, Yu
    Sun, Yongjun
    Huang, Gongsheng
    SCIENCE AND TECHNOLOGY FOR THE BUILT ENVIRONMENT, 2019, 25 (07) : 819 - 835