Estimation of rheological parameters using velocity measurements

被引:8
|
作者
Park, H. M. [1 ]
Hong, S. M. [1 ]
Lim, J. Y. [1 ]
机构
[1] Sogang Univ, Dept Chem & Biomol Engn, Seoul, South Korea
关键词
non-Newtonian fluids; numerical analysis; parameter identification; polymer processing; rheology; viscoelasticity;
D O I
10.1016/j.ces.2007.08.053
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
In the present investigation, we develop a method for estimating theological parameters of viscoelastic fluids using velocity measurement in a square straight channel. It is believed that a somewhat complicated patterns of secondary flows due to the non-zero second normal stress difference are more useful than the simple viscometric flows traditionally adopted in the determination of rheological parameters. The inverse problem of determining the rheological parameters from a set of velocity measurements is solved using a conjugate gradient method. When applied to a general constitutive equation encompassing the UCM model, the Oldroyd-B model and the PTT model, the present method is found to yield a reasonably accurate estimation of five theological parameters simultaneously even with noisy velocity measurements. (C) 2007 Elsevier Ltd. All rights reserved.
引用
收藏
页码:6806 / 6815
页数:10
相关论文
共 50 条
  • [41] Vehicle velocity estimation based on RSS measurements
    Stamoulakatos, Theodore S.
    Markopoulos, Antonis S.
    Anagnostou, Miltiadis E.
    Theologou, Michalis E.
    WIRELESS PERSONAL COMMUNICATIONS, 2007, 40 (04) : 523 - 538
  • [42] Estimation of velocity error for Doppler lidar measurements
    Frehlich, R
    JOURNAL OF ATMOSPHERIC AND OCEANIC TECHNOLOGY, 2001, 18 (10) : 1628 - 1639
  • [43] Vehicle Velocity Estimation Based on RSS Measurements
    Theodore S. Stamoulakatos
    Antonis S. Markopoulos
    Miltiadis E. Anagnostou
    Michalis E. Theologou
    Wireless Personal Communications, 2007, 40 : 523 - 538
  • [44] Riccati nonlinear observer for velocity-aided attitude estimation of accelerated vehicles using coupled velocity measurements
    Minh-Duc Hua
    Hamel, Tarek
    Samson, Claude
    2017 IEEE 56TH ANNUAL CONFERENCE ON DECISION AND CONTROL (CDC), 2017,
  • [45] ESTIMATION OF DETERMINISTIC PARAMETERS FROM MEASUREMENTS
    WILLEMS, JL
    AEU-INTERNATIONAL JOURNAL OF ELECTRONICS AND COMMUNICATIONS, 1977, 31 (02): : 90 - 91
  • [46] BAYES PARAMETERS ESTIMATION IN AMBIGUOUS MEASUREMENTS
    PENZIN, KV
    RADIOTEKHNIKA I ELEKTRONIKA, 1993, 38 (01): : 132 - 141
  • [47] On the estimation of interaction parameters in weak measurements
    Hofmann, Holger F.
    QUANTUM COMMUNICATION, MEASUREMENT AND COMPUTING (QCMC): THE TENTH INTERNATIONAL CONFERENCE, 2011, 1363
  • [48] Rheometry using velocity measurements
    Park, Hung Mok
    Shin, Kwang Sub
    Choi, Young Jin
    RHEOLOGICA ACTA, 2009, 48 (04) : 433 - 445
  • [49] Rheometry using velocity measurements
    Hung Mok Park
    Kwang Sub Shin
    Young Jin Choi
    Rheologica Acta, 2009, 48 : 433 - 445
  • [50] Influence of rheological parameters on the velocity of erythrocytes passing nailfold capillaries in humans
    Jung, F.
    Mrowietz, C.
    Hiebl, B.
    Franke, R. P.
    Pindur, G.
    Sternitzky, R.
    CLINICAL HEMORHEOLOGY AND MICROCIRCULATION, 2011, 48 (1-3) : 129 - 139