Bond Strength of Resin Cements to Co-Cr and Ni-Cr Metal Alloys Using Adhesive Primers

被引:16
|
作者
Di Francescantonio, Marina [1 ]
de Oliveira, Marcelo Tavares [1 ]
Garcia, Rubens Nazareno [2 ]
Romanini, Jose Carlos [3 ]
Franca Alves da Silva, Nelson Renato [4 ]
Giannini, Marcelo [1 ]
机构
[1] Univ Estadual Campinas, Piracicaba Dent Sch, Dept Restorat Dent, BR-13414903 Sao Paulo, Brazil
[2] Santa Catarina Dent Sch Univ, Dent Sch Univ, Dent Mat Sect, Joinville, SC, Brazil
[3] Romanini Dent Lab, Londrina, Parani, Brazil
[4] NYU, Coll Dent, Dept Prosthodont, New York, NY USA
关键词
Metal alloy; resin cement; bond strength; FIXED PARTIAL DENTURES; SURFACE-TREATMENT; TITANIUM; CROWNS;
D O I
10.1111/j.1532-849X.2009.00534.x
中图分类号
R78 [口腔科学];
学科分类号
1003 ;
摘要
Purpose: The aim of this study was to evaluate the effectiveness of adhesive primers (APs) applied to Co-Cr and Ni-Cr metal alloys on the bond strength of resin cements to alloys. Materials and Methods: Eight cementing systems were evaluated, consisting of four resin cements (Bistite II DC, LinkMax, Panavia F 2.0, RelyX Unicem) with or without their respective APs (Metaltite, Metal Primer II, Alloy Primer, Ceramic Primer). The two types of dental alloys (Co-Cr, Ni-Cr) were cast in plate specimens (10 x 5 x 1 mm(3)) from resin patterns. After casting, the plates were sandblasted with aluminum oxide (100 mu m) and randomly divided into eight groups (n = 6). Each surface to be bonded was treated with one of eight cementing systems. Three resin cement cylinders (0.5 mm high, 0.75 mm diameter) were built on each bonded metal alloy surface, using a Tygon tubing mold. After water storage for 24 hours, specimens were subjected to micro-shear testing. Data were statistically analyzed by two-way ANOVA and Tukey's studentized range test. Results: The application of Metal Primer II resulted in a significantly higher bond strength for LinkMax resin cement when applied in both metal alloys. In general, the cementing systems had higher bond strengths in Co-Cr alloy than in Ni-Cr. Conclusions: The use of AP between alloy metal surfaces and resin cements did not increase the bond strength for most cementing systems evaluated.
引用
收藏
页码:125 / 129
页数:5
相关论文
共 50 条
  • [21] Electrochemical behaviour of recasting Ni-Cr and Co-Cr non-precious dental alloys
    Ameer, MA
    Khamis, E
    Al-Motlaq, M
    CORROSION SCIENCE, 2004, 46 (11) : 2825 - 2836
  • [22] Electrochemical corrosion behavior, Vickers microhardness, and microstructure of Co-Cr and Ni-Cr dental alloys
    El-Bediwi, A.
    Saad, M.
    El-Fallal, A. A.
    El-Helaly, T.
    RADIATION EFFECTS AND DEFECTS IN SOLIDS, 2009, 164 (11): : 712 - 718
  • [23] Potentiostatic Oxide Growth Kinetics on Ni-Cr and Co-Cr Alloys: Potential and pH Dependences
    Musa, Ahmed Y.
    Behazin, Mehran
    Wren, Jungsook Clara
    ELECTROCHIMICA ACTA, 2015, 162 : 185 - 197
  • [24] IN VITRO ASSESSMENT OF Ni-Cr AND Co-Cr DENTAL ALLOYS UPON RECASTING: CELLULAR COMPATIBILITY
    Cairovic, Aleksandra
    Djordjevic, Ivan
    Bulatovic, Mirna
    Mojic, Marija
    Momcilovic, Miljana
    Stosic-Grujicic, Stanislava
    Maksimovic, Vesna
    Maksimovic-Ivanic, Danijela
    Mijatovic, Sanja
    Stamenkovic, Dragoslav
    DIGEST JOURNAL OF NANOMATERIALS AND BIOSTRUCTURES, 2013, 8 (02) : 877 - U461
  • [25] Preparation of Co and Cr metal coatings, and Ni-Cr and Co-Cr alloy coatings by cathode plasma electrlytic deposition
    Quan, Cheng
    He, Ye-Dong
    Cailiao Rechuli Xuebao/Transactions of Materials and Heat Treatment, 2015, 36 (06): : 185 - 190
  • [26] Retention between Ni-Cr alloy and adhesive cements.
    Franca, RDO
    Muench, A
    Cardoso, PEC
    JOURNAL OF DENTAL RESEARCH, 1997, 76 (05) : 985 - 985
  • [27] INFLUENCE OF pH VALUE AND NaF ADDITION ON THE CORROSION BEHAVIOR OF Ni-Cr AND Co-Cr DENTAL ALLOYS
    Dinu, Mihaela
    Tarcolea, Mihai
    Cojocaru, Mihai
    Gherghilescu, Ana Iulia
    Cotrut, Cosmin Mihai
    UNIVERSITY POLITEHNICA OF BUCHAREST SCIENTIFIC BULLETIN SERIES B-CHEMISTRY AND MATERIALS SCIENCE, 2015, 77 (02): : 149 - 158
  • [28] Influence of pH value and NaF addition on the corrosion behavior of Ni-Cr and Co-Cr dental alloys
    Dinu, Mihaela
    Târcolea, Mihai
    Cojocaru, Mihai
    Gherghilescu, Ana Iulia
    Cotruţ, Cosmin Mihai
    UPB Scientific Bulletin, Series B: Chemistry and Materials Science, 2015, 77 (02): : 149 - 158
  • [29] Tensile strength analysis of Titanium cp, compared to Ni-Cr and Co-Cr dental alloys, before and after laser welding.
    Mattos, MGC
    Ribeiro, RF
    Leal, MB
    Rodrigues, RCS
    Galo, R
    JOURNAL OF DENTAL RESEARCH, 2003, 82 : 162 - 162
  • [30] Evaluation of shear bond strength of repair acrylic resin to Co-Cr alloy
    Kulunk, Safak
    Kulunk, Togla
    Sarac, Duygu
    Cengiz, Seda
    Baba, Seniha
    JOURNAL OF ADVANCED PROSTHODONTICS, 2014, 6 (04): : 272 - 277