COMPUTATIONAL AND EXPERIMENTAL STUDIES OF MIDPASSAGE GAP LEAKAGE AND MISALIGNMENT FOR A NON-AXISYMMETRIC CONTOURED TURBINE BLADE ENDWALL

被引:0
|
作者
Lange, Eric [1 ]
Lynch, Stephen [1 ]
Lewis, Scott [2 ]
机构
[1] Penn State Univ, Mech & Nucl Engn Dept, University Pk, PA 16802 USA
[2] United Technol Pratt & Whitney, Turbine Durabil, 400 Main St, E Hartford, CT 06108 USA
关键词
D O I
暂无
中图分类号
O414.1 [热力学];
学科分类号
摘要
Turbine vanes and blades are generally manufactured as single or double airfoil sections that must each be installed onto a turbine disk. Between each section, a gap at the endwalls through the blade passage is present, through which high pressure coolant is leaked. Furthermore, sections can become misaligned due to thermal expansion or centrifugal forces. Flow and heat transfer around the gap is complicated due to the interaction of the mainstream and the leakage flow. An experimental and computational study was undertaken to determine the physics of the leakage flow interaction for a realistic turbine blade endwall, and assess whether steady RANS CFD, commonly used for non-axisymmetric endwall design, can be used to accurately model this interaction. Computational models were compared against experimental observations of endwall heat transfer on a contoured endwall with a midpassage gap. Endwall heat transfer coefficients were determined experimentally by using infrared thermography to capture spatially-resolved surface temperatures on a uniform heat flux surface (heater) attached to the endwall. Predictions and measurements both indicated an increase in endwall heat transfer with increasing gap leakage flow, although the distribution of heat transfer coefficients along the gap was not well captured by CFD. A misalignment of the blade endwall causing a forward-facing step for the near-endwall flow resulted in a large highly turbulent recirculation region downstream of the step and high local heat transfer that was overpredicted by CFD. Conversely, a backward-facing step. reduced turbulence and local heat transfer. The misprediction of local heat transfer around the gap is thought to be caused by unsteady interaction of the passage secondary flow and gap leakage flow, which cannot be well-captured by a steady RANS approach.
引用
收藏
页数:14
相关论文
共 50 条
  • [31] Effects of Slot Injection and Leakage Gap on Heat Transfer Characteristics of an Axisymmetric Turbine Endwall
    Zhang J.
    Liu C.-L.
    Zhang L.
    Zhu H.-R.
    Yao C.-Y.
    Yang Y.-Q.
    Tuijin Jishu/Journal of Propulsion Technology, 2022, 43 (04):
  • [32] Application of non-axisymmetric endwall contouring to conventional and high-lift turbine airfoils
    Praisner, T. J.
    Allen-Bradley, E.
    Grover, E. A.
    Knezevici, D. C.
    Sjolander, S. A.
    Proceedings of the ASME Turbo Expo 2007, Vol 6, Pts A and B, 2007, : 653 - 661
  • [33] Effect of Incoming Vortex on Secondary Flows in Turbine Cascades with Planar and Non-Axisymmetric Endwall
    CAO Zhiyuan
    WANG Chuxuan
    SONG Zhigao
    GAO Xi
    ZHAO Wei
    LIU Bo
    Journal of Thermal Science, 2024, 33 (01) : 138 - 157
  • [34] Investigation of improving the hydraulic turbine cascade performance using non-axisymmetric endwall contouring
    Meng, Lin
    Zhang, XiaoDong
    Yan, Gong
    Peng, Cancan
    ADVANCES IN MECHANICAL ENGINEERING, 2020, 12 (04)
  • [35] Effect of Incoming Vortex on Secondary Flows in Turbine Cascades with Planar and Non-Axisymmetric Endwall
    Zhiyuan Cao
    Chuxuan Wang
    Zhigao Song
    Xi Gao
    Wei Zhao
    Bo Liu
    Journal of Thermal Science, 2024, 33 : 138 - 157
  • [36] Effect of Incoming Vortex on Secondary Flows in Turbine Cascades with Planar and Non-Axisymmetric Endwall
    Cao, Zhiyuan
    Wang, Chuxuan
    Song, Zhigao
    Gao, Xi
    Zhao, Wei
    Liu, Bo
    JOURNAL OF THERMAL SCIENCE, 2024, 33 (01) : 138 - 157
  • [37] NON-AXISYMMETRIC ENDWALL PROFILING OF A STATOR ROW IN THE PRESENCE OF THE ROTOR IN A HIGH PRESSURE TURBINE
    Rehman, Abdul
    Liu, Bo
    Na, Zhenzhe
    Cheng, Hao
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBOMACHINERY TECHNICAL CONFERENCE AND EXPOSITION, 2018, VOL 2B, 2018,
  • [38] Effect of axial turbine non-axisymmetric endwall contouring on film cooling at different locations
    Chen, Pingting
    Wang, Lang
    Li, Xueying
    Ren, Jing
    Jiang, Hongde
    INTERNATIONAL JOURNAL OF HEAT AND MASS TRANSFER, 2020, 147
  • [39] Non-Axisymmetric Shroud Profiled Endwall Optimization of an Embedded Stator and Experimental Investigation
    Wang, Jiayu
    Hu, Jun
    Jiang, Chao
    Li, Jun
    ENERGIES, 2020, 13 (03)
  • [40] A Combined Numerical and Experimental Study of the Effect of Non-Axisymmetric Contouring on Performance and Film Cooling Behavior of a Rotating Turbine Endwall
    Lu, K.
    Rezasoltani, M.
    Schobeiri, M. T.
    Han, J. C.
    PROCEEDINGS OF THE ASME TURBO EXPO: TURBINE TECHNICAL CONFERENCE AND EXPOSITION, 2014, VOL 5B, 2014,