Surface tension measurement of glass melts using sessile or pendant drop methods

被引:9
|
作者
Chang, Yao-Yuan [1 ]
Lin, Shi-Yow [1 ]
机构
[1] Natl Taiwan Univ Sci & Technol, Dept Chem Engn, Taipei, Taiwan
关键词
Drop tensiometer; Glass melt; Pendant drop; Sessile drop; Surface tension; CONTACT-ANGLE; ELEVATED-TEMPERATURES; INTERFACIAL-TENSION; DENSITY; VISCOSITY; CALCIUM; LIQUIDS; ALUMINA; SHAPE;
D O I
10.1016/j.jtice.2011.05.005
中图分类号
TQ [化学工业];
学科分类号
0817 ;
摘要
The drop shape (sessile or pendant) method is widely used to measure the surface tension of glass melts. The accuracy of surface tension measurement has been improved by applying the technologies of video-image digitization and best-fitting algorithms. An accurate surface tension can be determined using hundreds of edge points from drop profiles and the best-fit with the drop profiles from the Young-Laplace equation. In this study, we examine the accuracy of measuring the surface tension of glass melts using the sessile or pendant drop methods. Experimental data show that the accuracy of surface tension measurement using the pendant drop method (+/- 3 mN/m) is better than that obtained by using the sessile drop method (+/- 9 to +/- 20 mN/m, depending on the contact angle). (C) 2011 Taiwan Institute of Chemical Engineers. Published by Elsevier B.V. All rights reserved.
引用
收藏
页码:922 / 928
页数:7
相关论文
共 50 条
  • [21] Influence of drop volume on surface tension evaluated using the pendant drop method
    Morita, AT
    Carastan, DJ
    Demarquette, NR
    COLLOID AND POLYMER SCIENCE, 2002, 280 (09) : 857 - 864
  • [23] Surface tension and specific volume of copper-titanium melts measured by the sessile drop method
    Krasovskyy, V
    Naidich, Y
    JOURNAL OF ADHESION SCIENCE AND TECHNOLOGY, 2004, 18 (04) : 465 - 471
  • [24] Measurement of surface tension of molten matte phases by an improved sessile drop method
    Hamuyuni, J.
    Taskinen, P.
    Akdogan, G.
    Bradshaw, S. M.
    TRANSACTIONS OF THE INSTITUTIONS OF MINING AND METALLURGY SECTION C-MINERAL PROCESSING AND EXTRACTIVE METALLURGY, 2012, 121 (03): : 173 - 177
  • [25] MEASUREMENT OF THE SURFACE TENSION OF TITANIFEROUS MOLTEN IRON BY THE SESSILE DROP METHOD.
    Luo, Weizhong
    Mao, Yuwen
    Huang, Lu
    Zhu, Yuankai
    Kang T'ieh/Iron and Steel (Peking), 1987, 22 (01): : 1 - 4
  • [26] SESSILE DROP PROFILES - CORRECTED METHODS FOR SURFACE-TENSION AND SPREADING COEFFICIENTS
    PADDAY, JF
    PROCEEDINGS OF THE ROYAL SOCIETY OF LONDON SERIES A-MATHEMATICAL AND PHYSICAL SCIENCES, 1972, 330 (1583): : 561 - &
  • [27] Surface tension measurement of normal human blood samples by pendant drop method
    Yadav S.S.
    Sikarwar B.S.
    Ranjan P.
    Janardhanan R.
    Goyal A.
    Journal of Medical Engineering and Technology, 2020, 44 (05): : 227 - 236
  • [28] Measurement of surface tension by sessile drop tensiometer with superoleophobic surface (vol 112, 121602, 2018)
    Kwak, Wonshik
    Park, Jun Kwon
    Yoon, Jinsung
    Lee, Sanghyun
    Hwang, Woonbong
    APPLIED PHYSICS LETTERS, 2018, 112 (16)
  • [30] MEASUREMENT OF SURFACE AND INTERFACIAL-TENSION FROM MAXIMUM PRESSURE IN SESSILE AND PENDANT BUBBLES AND DROPS
    RAMAKRISHNAN, S
    MAILLIET, K
    HARTLAND, S
    PROCEEDINGS OF THE INDIAN ACADEMY OF SCIENCES SECTION A, 1976, 83 (03): : 107 - 118