Porous graphitic carbon as a stationary phase in HPLC: Theory and applications

被引:138
|
作者
Pereira, Luisa [1 ]
机构
[1] Thermo Fisher Sci, Runcorn WA7 1PR, Cheshire, England
关键词
electronic interaction chromatography; hypercarb; isomers; polar retention effect on graphite; polar solutes; retention mechanisms;
D O I
10.1080/10826070802126429
中图分类号
Q5 [生物化学];
学科分类号
071010 ; 081704 ;
摘要
This paper gives an overview of the properties and behaviour of porous graphitic carbon (PGC) as a stationary phase in HPLC. Key applications areas that illustrate the capabilities of this chromatographic material to solve problem separations are reviewed. The retention mechanisms on this stationary phase for hydrophobic and polar solutes are described. PGCs' physical and chemical properties and the development of this unique chromatographic material are discussed. Over 140 references of applications of PGC in pharmaceutical, environmental, food safety, natural products, biochemical, clinical, and chemical warfare analysis are reviewed covering a range of solute properties.
引用
收藏
页码:1687 / 1731
页数:45
相关论文
共 50 条
  • [31] Separations of corticosteroids using electrochemically modulated liquid chromatography: Selectivity enhancements at a porous graphitic carbon stationary phase
    Ting, EY
    Porter, MD
    ANALYTICAL CHEMISTRY, 1997, 69 (04) : 675 - 678
  • [32] HPLC analysis of the herbicides diquat and paraquat using a porous graphitic carbon column
    Hare, S.
    Pereira, L.
    LC GC EUROPE, 2007, : 15 - 15
  • [33] HPLC analysis of PCBs on porous graphitic carbon: Retention behavior and gradient elution
    Pietrogrande, MC
    Benvenuti, A
    Previato, S
    Dondi, F
    CHROMATOGRAPHIA, 2000, 52 (7-8) : 425 - 432
  • [34] HPLC analysis of PCBs on porous graphitic carbon: Retention behavior and gradient elution
    M. C. Pietrogrande
    A. Benvenuti
    S. Previato
    F. Dondi
    Chromatographia, 2000, 52 : 425 - 432
  • [35] A comparison of silica and porous graphitic carbon as support materials for a chiral selector in HPLC
    Oxelbark, J
    Claeson, S
    TETRAHEDRON-ASYMMETRY, 2002, 13 (20) : 2235 - 2240
  • [36] ENANTIOMER SEPARATIONS BY SUPERCRITICAL-FLUID CHROMATOGRAPHY ON A CHIRAL STATIONARY-PHASE PHYSICALLY ANCHORED TO POROUS GRAPHITIC CARBON
    WILKINS, SM
    TAYLOR, DR
    SMITH, RJ
    JOURNAL OF CHROMATOGRAPHY A, 1995, 697 (1-2) : 587 - 590
  • [37] Liquid chromatographic determination of methylamines. Determination of trimethylamine in fish samples using a porous graphitic carbon stationary phase
    Monser, LI
    Greenway, GM
    ANALYTICA CHIMICA ACTA, 1996, 322 (1-2) : 63 - 68
  • [38] The utility of porous graphitic carbon as a stationary phase in proteomics workflows: Two-dimensional chromatography of complex peptide samples
    Griffiths, John R.
    Perkins, Simon
    Connolly, Yvonne
    Zhang, Lu
    Holland, Mark
    Barattini, Valeria
    Pereira, Luisa
    Edge, Anthony
    Ritchie, Harald
    Smith, Duncan L.
    JOURNAL OF CHROMATOGRAPHY A, 2012, 1232 : 276 - 280
  • [39] Ion-pair chromatography on a porous graphitic carbon stationary phase for the analysis of twenty underivatized protein amino acids
    Chaimbault, P
    Petritis, K
    Elfakir, C
    Dreux, M
    JOURNAL OF CHROMATOGRAPHY A, 2000, 870 (1-2) : 245 - 254
  • [40] Ion-interaction Rp-HPLC separation of inorganic anions on porous graphitized carbon stationary phase. Comparison with ods stationary phase
    Gennaro, MC
    Marengo, E
    Gianotti, V
    JOURNAL OF LIQUID CHROMATOGRAPHY & RELATED TECHNOLOGIES, 2000, 23 (17) : 2599 - 2613