Comparison of glue versus suture mesh fixation for primary open inguinal hernia mesh repair by Lichtenstein technique: a systematic review and meta-analysis

被引:5
|
作者
Phoa, Shaun [1 ]
Chan, Kai Siang [2 ]
Lim, Sioh Huang [1 ]
Oo, Aung Myint [1 ,2 ,3 ]
Shelat, Vishal G. [1 ,2 ,3 ]
机构
[1] Natl Univ Singapore, Yong Loo Lin Sch Med, Singapore 117597, Singapore
[2] Tan Tock Seng Hosp, Dept Gen Surg, Singapore 308433, Singapore
[3] Nanyang Technol Univ, Lee Kong Chian Sch Med, Singapore 308232, Singapore
关键词
inguinal hernia repair; Lichtenstein; recurrence; tension-free; open; mesh; RANDOMIZED CLINICAL-TRIAL; HUMAN FIBRIN GLUE; RISK-FACTORS; CHRONIC PAIN; POSTOPERATIVE COMPLICATIONS; LIGHTWEIGHT MESH; PROSTHETIC MESH; OPERATING TIME; GROIN HERNIA; TISSUE GLUE;
D O I
10.1007/s10029-022-02571-4
中图分类号
R61 [外科手术学];
学科分类号
摘要
Background The use of glue as a mesh fixator in open Lichtenstein inguinal hernia repair (IHR) has gained popularity to reduce recurrence and postoperative complications. This meta-analysis aims to provide an up-to-date review to compare glue versus suture fixation in primary open Lichtenstein IHR. Methods PubMed, Embase, The Cochrane Library, Web of Science, and Springer were systematically searched till June 2021 for randomized controlled trials (RCTs) comparing glue versus suture fixation in open Lichtenstein IHR. Primary outcomes were early (at 1 year) and late recurrence (5 years or more). Secondary outcomes were the length of operation, postoperative haematoma and seroma, and chronic pain at 1 year. Results A total of 17 RCTs with 3150 hernias (glue n = 1582, suture n = 1568) were included. Only three studies reported late recurrence. Glue fixation was associated with shorter operative duration (MD - 4.17, 95% CI - 4.82, - 3.52; p < 0.001 and a lower incidence of haematoma formation (OR 0.51, 95% CI 0.32, 0.81; p = 0.004). There was no significant difference in postoperative seroma (OR 0.72, 95% CI 0.35, 1.49; p = 0.38), chronic pain after 1 year (OR 1.10, 95% CI 0.73, 1.65; p = 0.65), early recurrence (OR 1.11, 95% CI 0.45, 2.76; p = 0.81, I-2 = 0%), and late recurrence (OR 1.23, 95% CI 0.59, 2.59; p = 0.59, I-2 = 0%). Conclusion Early and late recurrence were comparable between glue and suture fixation in open Lichtenstein IHR patients. Glue fixation had shorter operating time and lower haematoma formation than suture fixation. Chronic pain and seroma formation were comparable. More RCTs should report long-term outcomes.
引用
收藏
页码:1105 / 1120
页数:16
相关论文
共 50 条
  • [31] MESH VERSUS SUTURE FOR ELECTIVE PRIMARY UMBILICAL HERNIA REPAIR: A SYSTEMATIC REVIEW AND META-ANALYSIS
    Rasador, A. C. Dias
    da Silveira, C. A. Balthazar
    Lima, D. L.
    Nogueira, R.
    Malcher, F.
    Sreeramoju, P.
    Cavazzola, L. T.
    BRITISH JOURNAL OF SURGERY, 2024, 111
  • [32] Fibrin glue versus sutures for mesh fixation in open repair of inguinal hernia
    Abdelwahab, Elsayed M.
    Abdelaziz, Heba T.
    Metwally, Ahmed G. E.
    EGYPTIAN JOURNAL OF SURGERY, 2024, 43 (03): : 861 - 866
  • [33] Mesh Repair Versus Non-Mesh Repair for Strangulated Inguinal Hernia: Systematic Review with Meta-Analysis
    Hassen Hentati
    Wajih Dougaz
    Chadli Dziri
    World Journal of Surgery, 2014, 38 : 2784 - 2790
  • [34] Mesh Repair Versus Non-Mesh Repair for Strangulated Inguinal Hernia: Systematic Review with Meta-Analysis
    Hentati, Hassen
    Dougaz, Wajih
    Dziri, Chadli
    WORLD JOURNAL OF SURGERY, 2014, 38 (11) : 2784 - 2790
  • [35] Laparoscopic versus open mesh repair for the treatment of recurrent inguinal hernia: a systematic review and meta-analysis
    Yang, Chun
    Deng, Shaoping
    ANNALS OF PALLIATIVE MEDICINE, 2020, 9 (03) : 1164 - 1173
  • [36] Systematic review and meta-analysis of the use of lightweight versus heavyweight mesh in open inguinal hernia repair
    Sajid, M. S.
    Leaver, C.
    Baig, M. K.
    Sains, P.
    BRITISH JOURNAL OF SURGERY, 2012, 99 (01) : 29 - 37
  • [37] Meta-analysis of mesh-plug repair and Lichtenstein repair in the treatment of primary inguinal hernia
    Miao Yu
    Wen-Xian Xie
    Sheng Li
    Deng-Chao Wang
    Li-Yan Huang
    Updates in Surgery, 2021, 73 : 1297 - 1306
  • [38] Open tension-free Lichtenstein repair of inguinal hernia: use of fibrin glue versus sutures for mesh fixation
    Negro, P.
    Basile, F.
    Brescia, A.
    Buonanno, G. M.
    Campanelli, G.
    Canonico, S.
    Cavalli, M.
    Corrado, G.
    Coscarella, G.
    Di Lorenzo, N.
    Falletto, E.
    Fei, L.
    Francucci, M.
    Baldelli, C. Fronticelli
    Gaspari, A. L.
    Gianetta, E.
    Marvaso, A.
    Palumbo, P.
    Pellegrino, N.
    Piazzai, R.
    Salvi, P. F.
    Stabilini, C.
    Zanghi, G.
    HERNIA, 2011, 15 (01) : 7 - 14
  • [39] Meta-analysis of mesh-plug repair and Lichtenstein repair in the treatment of primary inguinal hernia
    Yu, Miao
    Xie, Wen-Xian
    Li, Sheng
    Wang, Deng-Chao
    Huang, Li-Yan
    UPDATES IN SURGERY, 2021, 73 (04) : 1297 - 1306
  • [40] Glue versus tackers for mesh fixation in laparoscopic inguinal hernia repair: a meta-analysis and trial sequential analysis
    Kitching, Samuel
    Patel, Agastya
    Tan, Jacob
    Kadamapuzah, Jacob
    Satyadas, Thomas
    HERNIA, 2025, 29 (01)