Assessment of right ventricular function for patients with rheumatic mitral stenosis by 64-slice multi-detector row computed tomography: comparison with magnetic resonance imaging

被引:4
|
作者
Zhang Xiao-chun [2 ]
Yang Zhi-gang [1 ]
Guo Yin-kun [1 ]
Zhang Rui-ming [3 ]
Wang Jian [2 ]
Zhou Dai-quan [2 ]
Cheng Lin [2 ]
Chen Lin [2 ]
机构
[1] Sichuan Univ, W China Hosp, Dept Radiol, Chengdu 610041, Sichuan, Peoples R China
[2] Third Mil Med Univ, Southwest Hosp, Dept Radiol, Chongqing 400038, Peoples R China
[3] First Affiliated Hosp, Inner Mongolia Med Coll, Dept Gen Surg, Hohhot 410041, Inner Mongolia, Peoples R China
关键词
cardiac imaging techniques; ventricular function; mitral valve stenosis; magnetic resonance imaging; VALVULAR HEART-DISEASE; EJECTION FRACTION; CARDIAC-FUNCTION; CT; ECHOCARDIOGRAPHY; ACCURACY; REPRODUCIBILITY; FAILURE; VOLUMES;
D O I
10.3760/cma.j.issn.0366-6999.2012.08.020
中图分类号
R5 [内科学];
学科分类号
1002 ; 100201 ;
摘要
Background Right ventricular (RV) dysfunction ensues due to rheumatic mitral stenosis (RMS). The evaluation of RV function is clinically important for the diagnosis, treatment, and follow-up for patients with different degrees of RMS. The purpose of this study was to determine whether the 64-slice multi-detector row computed tomography (64-slice MDCT) can assess the RV function in RMS with high accuracy and reproducibility when compared to MR imaging (MRI). Methods Right ventricular end-diastolic and end-systolic volumes (RV-EDV and RV-ESV), stroke volume (RV-SV), ejection fraction (RV-EF), cardiac output (RV-CO), and wall mass (RV-Mass) were measured with dedicated cardiac analysis software on 64-slice MDCT and compared with values measured with MRI in 43 consecutive patients with RMS. Agreement between MRI and 64-MDCT results were compared with Bland and Altman analysis and linear regression analysis. Repeated measurements were performed to determine intraobserver and interobserver variability. Results No significant differences were revealed in calculated RV function parameters between the two methods. RV-EDV, RV-ESV, RV-SV, RV-EF, RV-CO, and RV-Mass by 64-slice MDCT were similar to those by MRI (P>0.05). There were good correlations (r=0.98, 0.97, 0.96, 0.96, 0.95 and 0.77, respectively) and close agreement (bias=-0.2 ml, -1.0 ml, 0.8 ml, 0.5%, 26.1 ml, and 0.5 g, respectively, P>0.05). The variability in 64-slice MDCT measurements was similar to that in MRI values. Conclusion ECG-gated 64-slice MDCT could assess the RV function in RMS with high accuracy and reproducibility when compared to MRI. Chin Med J 2012;125(8):1469-1474
引用
收藏
页码:1469 / 1474
页数:6
相关论文
共 50 条
  • [41] Comparison of 64-slice computed tomography planimetry and Doppler echocardiography in the assessment of aortic valve stenosis
    Habis, Michel
    Daoud, Beatrice
    Roger, Veronique L.
    Ghostine, Said
    Caussin, Christophe
    Ramadan, Ramzi
    Nottin, Remi
    Lancelin, Bernard
    Angel, Claude-Yves
    Capderou, Andre
    Paul, Jean-Francois
    JOURNAL OF HEART VALVE DISEASE, 2007, 16 (03): : 216 - 224
  • [42] Real-time three-dimensional echocardiographic left ventricular systolic assessment: side-by-side comparison with 64-slice multi-detector cardiac computed tomography
    Vieira, Marcelo L. C.
    Nomura, Cesar H.
    Tranchesi, Bernardino, Jr.
    de Oliveira, Wercules A.
    Naccarato, Gustavo
    Serpa, Bruna S.
    Passos, Rodrigo B. D.
    Funari, Marcelo B. G.
    Fischer, Claudio H.
    Morhy, Samira S.
    EUROPEAN JOURNAL OF ECHOCARDIOGRAPHY, 2010, 11 (03): : 257 - 263
  • [43] Clinically significant non-cardiac findings are common in 64-slice multi-detector computed tomography of the heart
    Zimbwa, Peter
    Narayan, Shoba B.
    Schoenhagen, Paul
    Desai, Milind Y.
    Garcia, Mario J.
    Sola, Srikanth
    JOURNAL OF THE AMERICAN COLLEGE OF CARDIOLOGY, 2007, 49 (09) : 135A - 135A
  • [44] The relationship between coronary artery calcification as assessed by 64-slice multi-detector computed tomography and arterial stiffness
    Park, J. -S.
    Choi, U. -J.
    Lee, Y. -H.
    Lee, Y. -S.
    Hwang, J. -W.
    Lim, H. -S.
    Kang, S. -J.
    Choi, B. -J.
    Choi, S. -Y.
    Yoon, M. -H.
    Hvang, G. -S.
    Tahk, S. -J.
    Shin, J. -H.
    JOURNAL OF HYPERTENSION, 2008, 26 : S179 - S179
  • [45] Assessment of left atrial volume and function in patients with permanent atrial fibrillation: comparison of cardiac magnetic resonance imaging, 320-slice multi-detector computed tomography, and transthoracic echocardiography
    Agner, Bue F. Ross
    Kuhl, Jorgen Tobias
    Linde, Jesper James
    Kofoed, Klaus F.
    Akeson, Per
    Rasmussen, Bo V.
    Jensen, Gorm B.
    Dixen, Ulrik
    EUROPEAN HEART JOURNAL-CARDIOVASCULAR IMAGING, 2014, 15 (05) : 532 - 540
  • [46] Volumetric analysis of coronary plaque characterization in patients with metabolic syndrome using 64-slice multi-detector computed tomography (MDCT)
    Arai, Kosuke
    Amano, Tetsuya
    Uetani, Tadayuki
    Nanki, Michio
    Marui, Nobuyuki
    Kato, Masataka
    Yokoi, Kiminobu
    Ando, Hirohilko
    Kumagai, Soichiro
    Izawa, Hideo
    Matsubara, Tatsuaki
    Murohara, Toyoaki
    CIRCULATION, 2007, 116 (16) : 692 - 692
  • [47] Direct comparison of 32-element magnetic resonance imaging at 3.0 T and 64-slice computed tomography for detection of coronary artery stenosis
    Hamdan, A.
    Asbach, P.
    Kilian, H.
    Gebker, R.
    Paetsch, I.
    Jahnke, C.
    Huppertz, A.
    Fleck, E.
    EUROPEAN HEART JOURNAL, 2009, 30 : 486 - 487
  • [48] MAGNETIC RESONANCE IMAGING IDENTIFIES OCCULT HIP FRACTURES MISSED BY 64-SLICE COMPUTED TOMOGRAPHY
    Hakkarinen, David K.
    Banh, Kenny V.
    Hendey, Gregory W.
    JOURNAL OF EMERGENCY MEDICINE, 2012, 43 (02): : 303 - 307
  • [49] Assessment of global and regional left ventricular function using 64-slice multislice computed tomography and 2D echocardiography: A comparison with cardiac magnetic resonance
    Annuar, Bin Rapaee
    Liew, Chee Khoon
    Chin, Sze Piaw
    Ong, Tiong Kiam
    Seyfarth, M. Tobias
    Chan, Wei Ling
    Fong, Yean Yip
    Ang, Choon Kiat
    Lin, Naing
    Liew, Houng Bang
    Sim, Kui Hian
    EUROPEAN JOURNAL OF RADIOLOGY, 2008, 65 (01) : 112 - 119
  • [50] Thick maximum intensity projections for the assessment of left ventricular function with 64-slice computed tomography
    Husmann, Lars
    Leschka, Sebastian
    Desbiolles, Lotus
    Schepis, Tiziano
    Koepfli, Pascal
    Gaemperli, Oliver
    Seifert, Burkhardt
    Flohr, Thomas G.
    Frauenfelder, Thomas
    Marincek, Borut
    Kaufmann, Philipp A.
    Alkadhi, Hatem
    INVESTIGATIVE RADIOLOGY, 2006, 41 (10) : 746 - 752