Application of a Redundant Haptic Interface in Enhancing Soft-Tissue Stiffness Discrimination

被引:27
|
作者
Torabi, Ali [1 ]
Khadem, Mohsen [2 ]
Zareinia, Kourosh [3 ]
Sutherland, Garnette Roy [4 ]
Tavakoli, Mahdi [1 ]
机构
[1] Univ Alberta, Dept Elect & Comp Engn, Edmonton, AB T6G 2R3, Canada
[2] Univ Edinburgh, Sch Informat, Edinburgh EH8 9YL, Midlothian, Scotland
[3] Ryerson Univ, Dept Mech Engn, Toronto, ON M5B 2K3, Canada
[4] Univ Calgary, Fac Med, Project NeuroArm, Calgary, AB T2N 1N4, Canada
来源
基金
加拿大创新基金会;
关键词
Haptics and haptic interfaces; telerobotics and teleoperation; medical robots and systems; ROBOT MANIPULATORS; TELEOPERATION SYSTEMS; FEEDBACK; PERFORMANCE;
D O I
10.1109/LRA.2019.2893606
中图分类号
TP24 [机器人技术];
学科分类号
080202 ; 1405 ;
摘要
Haptic-enabled teleoperated surgical systems have the potential to enhance the accuracy and performance of surgical interventions. The user interface of such a system can provide haptic feedback to the surgeon to more intuitively perform surgical tasks. In this letter, we study the added benefits of redundant manipulators as haptic interfaces for teleoperated surgical systems. First, we introduce the intrinsic benefits of employing a redundant haptic interface, namely, reduced apparent inertia and increased manipulability (one result ofwhich is reduced friction forces). Next, we demonstrate that the haptic interface redundancy can further reduce its apparent inertia and friction via appropriately manipulating the extra degrees of freedom of the interface. This will consequently enhance the haptic feedback resolution (sensitivity) for the user. Finally, a psychophysical experiment is performed to validate the improved force perception for the user in a virtual soft-tissue palpation task. We conduct a set of perceptual experiments to evaluate how a redundant and non-redundant user interface affects the perception of the virtual stiffness. Experimental results demonstrate that the redundancy in the haptic user interface helps to enhance tissue stiffness discrimination ability of the user by reducing the distortions caused by the kinematics and dynamics of the user interface.
引用
收藏
页码:1037 / 1044
页数:8
相关论文
共 50 条
  • [41] THE APPLICATION OF INTRAOPERATIVE RADIOTHERAPY IN THE SURGICAL-TREATMENT OF RETROPERITONEAL SOFT-TISSUE SARCOMA
    WILLEKE, F
    EBLE, MJ
    LEHNERT, T
    SCHWARZBACH, M
    HINZ, U
    WANNENMACHER, M
    HERFARTH, C
    CHIRURG, 1995, 66 (09): : 899 - 904
  • [42] COMPUTED-TOMOGRAPHY IN BONE AND SOFT-TISSUE NEOPLASM - APPLICATION AND PATHOLOGIC CORRELATION
    ROSENTHAL, DI
    CRC CRITICAL REVIEWS IN DIAGNOSTIC IMAGING, 1982, 18 (04) : 243 - 278
  • [43] Relapsed clubfoot correction with soft-tissue release and selective application of Ilizarov technique
    Malizos, Konstantinos N.
    Gougoulias, Nikolaos E.
    Dailiana, Zoe H.
    Rigopoulos, Nikolaos
    Moraitis, Theofanis
    STRATEGIES IN TRAUMA AND LIMB RECONSTRUCTION, 2008, 3 (03): : 109 - 117
  • [44] Application of Topological Sensitivity Toward Soft-Tissue Characterization From Vibroacoustography Measurements
    Yuan, Huina
    Guzina, Bojan B.
    Chen, Shigao
    Kinnick, Randall
    Fatemi, Mostafa
    JOURNAL OF COMPUTATIONAL AND NONLINEAR DYNAMICS, 2013, 8 (03):
  • [45] COMPUTED-TOMOGRAPHY APPLICATION TO ASSESS LOCAL EXTENSION OF SOFT-TISSUE TUMORS
    LUKYANCHENKO, AB
    SOKOLOVSKY, VA
    VOPROSY ONKOLOGII, 1991, 37 (03) : 316 - 321
  • [46] Conditioned haptic perception for 3D localization of nodules in soft tissue palpation with a variable stiffness probe
    Herzig, Nicolas
    He, Liang
    Maiolino, Perla
    Abad, Sara-Adela
    Nanayakkara, Thrishantha
    PLOS ONE, 2020, 15 (08):
  • [47] Effect of pulse characteristics on temperature rise due to ultrasound absorption at a bone/soft-tissue interface
    Myers, MR
    JOURNAL OF THE ACOUSTICAL SOCIETY OF AMERICA, 2005, 117 (05): : 3281 - 3287
  • [48] Assessment of the Soft-Tissue Seal at the Interface between the Base of the Fixed Denture Pontic and the Oral Mucosa
    Atsuta, Ikiru
    Narimatsu, Ikue
    Morimoto, Taichiro
    Cheng, Chi-Hsiang
    Koyano, Kiyoshi
    Ayukawa, Yasunori
    MATERIALS, 2021, 14 (14)
  • [49] Soft-Tissue / Bone Interface Backscatter Prediction by Two Commercial Electron Treatment Planning Algorithms
    Catt, B.
    Yudelev, M.
    MEDICAL PHYSICS, 2015, 42 (06) : 3499 - 3499
  • [50] CRYOFRACTURE - A TECHNIQUE FOR THE EXAMINATION OF HARD IMPLANT AND SOFT-TISSUE INTERFACE BY SCANNING ELECTRON-MICROSCOPY
    MORDAN, N
    HILL, TR
    BARBER, P
    JOURNAL OF DENTAL RESEARCH, 1987, 66 (04) : 888 - 888